Xiangyang Li

Prof. Xiangyang Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YKYiqian Kong
Yiqian Kong
ZLZongyi Li
Zongyi Li
LZLili Zhang
Lili Zhang
JSJuncheng Song
Juncheng Song
QLQi Liu
Qi Liu
XLXiangyang Li
Xiangyang Li

17 June 2023 in Food Chemistry
Verified
Journal Article
Closed access
YKYiqian Kong
Yiqian Kong
YZYinghua Zhu
Yinghua Zhu
JSJuncheng Song
Juncheng Song
QLQi Liu
Qi Liu
LSLili Song
Lili Song
XLXiangyang Li
Xiangyang Li

1 December 2019 in Talanta
Verified
Journal Article
Closed access
MGManli Guo
Manli Guo
QHQin Hou
Qin Hou
Geoffrey Ivan Neil WaterhouseGeoffrey Ivan Neil Waterhouse
Geoffrey Ivan Neil Waterhouse
JHJuying Hou
Juying Hou
SAShiyun Ai
Shiyun Ai
XLXiangyang Li
Xiangyang Li

1 September 2020 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
MGManli Guo
Manli Guo
JCJingtian Chi
Jingtian Chi
YLYijing Li
Yijing Li
Geoffrey Ivan Neil WaterhouseGeoffrey Ivan Neil Waterhouse
Geoffrey Ivan Neil Waterhouse
SAShiyun Ai
Shiyun Ai
XLXiangyang Li
Xiangyang Li

1 March 2021 in Food Chemistry
Verified
Journal Article
Closed access
MGManli Guo
Manli Guo
JCJingtian Chi
Jingtian Chi
CZChi Zhang
Chi Zhang
MWMinglin Wang
Minglin Wang
HLHui Liang
Hui Liang
XLXiangyang Li
Xiangyang Li

9 July 2020 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
JCJingtian Chi
Jingtian Chi
MGManli Guo
Manli Guo
CZChi Zhang
Chi Zhang
YZYuanhong Zhang
Yuanhong Zhang
SAShiyun Ai
Shiyun Ai
XLXiangyang Li
Xiangyang Li
In this work, glucose oxidase and Au nanoclusters co-encapsulated in zeolitic imidazolate frameworks (GOx & AuNCs@ZIF-8) were obtained by simply mixing Zn2+, dimethylimidazole, glucose oxidase (GOx) and Au nanoclusters (AuNCs) at room temperature. The GOx & AuNCs@ZIF-8 composite can be used as a sensitive colorimetric sensor for glucose based on the following cascade reaction: GOx converts glucose to gluconic acid and generates H2O2, which acts as a substrate for AuNCs oxidizing 3,3′,5,5′-tetramethylbenzidine (TMB) to form oxidized TMB (oxTMB) detectable at 652 nm. Owing to the effective cascade reaction and protective effect of the ZIF-8 shell on enzymes, the catalytic activity of GOx & AuNCs@ZIF-8 was enhanced 19.3-fold compared with the free GOx/AuNC solution, and the glucose sensor showed high selectivity and sensitivity. Furthermore, the GOx & AuNCs@ZIF-8 composite showed high long-term storage stability and stability against digesting enzymes and chelating compounds due to the shielding effect of the ZIF-8 scaffold.