Shefra Shah

Shefra Shah


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2025 in Methods and Protocols
Verified
Journal Article
Open access
SSShefra Shah
Shefra Shah
FHFarah Hussaini
Farah Hussaini
DMDumitru Mazilu
Dumitru Mazilu
EBEric E. Bennett
Eric E. Bennett
HWHan Wen
Han Wen
In computed tomography (CT)-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. We describe an easy-to-replicate cystic lung phantom consisting of basic lung structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner, various structures in the lung phantom were correctly recognized by two types of lung analysis software. The resulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. The significant finding was that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and deserves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.

25 March 2025 in arXiv
Verified
Preprint
Open access
PDF file
SSShefra Shah
Shefra Shah
FHFarah Hussaini
Farah Hussaini
DMDumitru Mazilu
Dumitru Mazilu
EBEric E. Bennett
Eric E. Bennett
HWHan Wen
Han Wen
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.