Daniel Nguyen

Dr. Daniel Nguyen


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2023 in Academic Radiology
Verified
Journal Article
Closed access
DNDaniel Nguyen
Daniel Nguyen
DSDaniel Swanson
Daniel Swanson
ANAlex Newbury
Alex Newbury
YKYoung H. Kim
Young H. Kim


6 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
DNDaniel Nguyen
Daniel Nguyen
TSTina Shiang
Tina Shiang
CGConnie Ge
Connie Ge
GWGeorge Watts
George Watts
CSChristopher Sereni
Christopher Sereni
YKYoung Kim
Young Kim
Objective: To evaluate the feasibility of simulated ultra-low-dose CT (ULD-CT) enhanced with deep learning denoising (DLD) for detecting pelvic and hip fractures. Method: This Institutional Review Board-approved retrospective study was performed at a multisite, single academic institution between October 2020 and May 2021, including 30 full-dose CT (CTfull) exams of acute pelvic and hip trauma (10 normal, 10 “easy,” 10 “hard” cases by fracture conspicuity). Simulated low-dose CT images at 10% (CT10sim) and 5% (CT5sim) radiation dose were generated using a noise model-based algorithm and reconstructed from full-dose CT datasets. A commercial deep learning denoising algorithm enhanced these images, resulting in denoised low-dose CTs (CT10dld and CT5dld) for evaluation. The 90 resulting CT cases were reviewed independently for diagnostic accuracy, confidence, sufficiency, and imaging quality. Result: Diagnostic accuracy was similar across CT modalities overall (CTfull 80.8% [72.9, 86.9]; CT10dld 78.3% [70.1, 84.8]; CT5dld 77.5% [69.2, 84.1]) and within the easy and normal strata; in hard cases, accuracy was numerically lower for CT10dld (45.0%) and CT5dld (42.5%) than for CTfull (57.5%). Diagnostic sufficiency was similarly high across modalities (CTfull 91.7%, CT10dld 87.5%, CT5dld 88.3%). CT full was rated highest in perceived image quality across all strata (mean 4.21 ± 0.83 overall vs. 3.47 ± 0.97 for CT10dld and 3.23 ± 0.98 for CT5dld) and in diagnostic confidence (mean 4.61 ± 0.63 vs. 4.45 ± 0.71 and 4.41 ± 0.72, respectively), though neither translated into a corresponding drop in diagnostic accuracy overall. Inter-reader agreement was highest between MSK radiologists, reaching substantial agreement on CT10dld (κ = 0.760) and CT5dld (κ = 0.672). Conclusions: DLD-enhanced ULD-CT showed diagnostic accuracy and sufficiency similar to full-dose CT for pelvic and hip fracture detection, at a fraction of the radiation dose, though full-dose CT was rated higher in perceived image quality and diagnostic confidence and outperformed denoised low-dose CT numerically in hard cases. Full-dose CT remains the preferred modality for complex and high-energy trauma, while denoised low-dose CT modalities represent a promising option for straightforward presentations where radiation minimization is a priority.