Direct lightning discharges in overhead distribution networks invariably cause serious insulation damage, frequently leading to the electric system’s partial or total shutdown. Installing lightning arresters can be very effective, and it is commonly used to minimize this problem; however, considering that typically, electric distribution grids exhibit a very large number of electrical nodes, the massive use of lightning arresters may not be economically viable. In this way, this article proposes a methodology for allocating lightning arresters that can significantly reduce the number of lightning arresters installed, but at the same time maintaining an adequate protection level for the distribution grid. The proposed methodology, named Direct Discharge Crossing (DDC), analyzes the network criticality based on two main factors, which are the overvoltage magnitudes and the number of flashovers provoked by lightning discharges, and defines a feeder lightning performance function that is used to indicate the recommended location for lightning arresters’ installation. The simulation studies are accomplished using the IEEE 34 bus distribution grid and ATP software to demonstrate the efficacy of the proposed solution, which is confirmed by the results presented.
The efficient protection of electric power distribution networks against lightning discharges is a crucial problem for distribution electric utilities. To solve this problem, the great challenge is to find a solution for the installation of surge arresters at specific points in the electrical grid and in a sufficient quantity that can ensure an adequate level of equipment protection and be within the utility’s budget. As a solution to this problem of using ATP (Alternative Transient Program), this paper presents a methodology for optimized surge arrester allocation based on genetic algorithm (GA), with a fitness function that maximizes the number of protected equipment according to the financial availability for investment in surge arresters. As ATP may demand too much processing time when running large distribution grids, an innovative procedure is implemented to obtain an overvoltage severity description of the grid and select only the most critical electric nodes for the incidence of lightning discharges, in the GA allocation procedure. The results obtained for the IEEE-123 bus electric feeder indicate a great reduction of flashover occurrence, thus increasing the equipment protection level.
Several dynamic projects and fault diagnosis of mechanical structures require the knowledge of the acting external forces. However, the measurement of such forces is often difficult or even impossible; in such cases, an inverse problem must be solved. This paper proposes a force identification method that uses the response surface methodology (RSM) based on central composite design (CCD) in conjunction with a random forest regression algorithm. The procedure initially required the finite element modal model of the forced structure. Harmonic analyses were then performed with varied parameters of forces, and RSM generated a dataset containing the values of amplitude, frequency, location of forces, and vibration acceleration at several points of the structure. The dataset was used for training and testing a random forest regression model for the prediction of any location, amplitude, and frequency of the force to be identified with information on only the vibration acquisition at certain points of the structure. Numerical results showed excellent accuracy in identifying the force applied to the structure.