John Wilson

John Wilson

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1996
Verified
Report
Closed access
PDF file
TWTodd H. Wiedemeier
Todd H. Wiedemeier
JWJohn Wilson
John Wilson
JHJerry E. Hansen
Jerry E. Hansen
FCFrancis H. Chapelle
Francis H. Chapelle
MSMatthew A. Swanson
Matthew A. Swanson
Over the past several years remediation by natural attenuation has become increasingly accepted as a remedial alternative for organic compounds dissolved in groundwater. The United States Environmental Protection Agency (USEPA) defines natural attenuation as (OSWER, 1996): The term 'Natural Attenuation' refers to naturally-occurring processes in soil and groundwater environments that act without human intervention to reduce the mass, toxicity, mobility, volume, or concentration of contaminants in those media. These in-situ processes include biodegradation, dispersion, dilution, adsorption, volatilization, and chemical or biological stabilization or destruction of contaminants. In practice, natural attenuation also is referred to by several other names, such as intrinsic remediation, intrinsic bioremediation, natural restoration, or passive bioremediation. The goal of any site characterization effort is to understand the fate and transport of the contaminants of concern over time in order to assess any current or potential threat to human health or the environment. Natural attenuation processes, such as biodegradation, can often be dominant factors in the fate and transport of contaminants. Thus, consideration and quantification of natural attenuation is essential to a more thorough understanding of contaminant fate and transport.

15 February 2018 in Groundwater Monitoring & Remediation
Verified
Journal Article
Closed access
PDF file
JMJames C. Mills
James C. Mills
JWJohn Wilson
John Wilson
BWBarbara H. Wilson
Barbara H. Wilson
TWTodd H. Wiedemeier
Todd H. Wiedemeier
DFDavid Freedman
David Freedman

1 October 2024 in Remediation Journal
Verified
Journal Article
Open access
JBJeremy Birnstingl
Jeremy Birnstingl
JWJohn Wilson
John Wilson
This article compares the full installation and operational costs of a hydraulic containment (“pump‐and‐treat,” P&T) system with those of a hypothetical contemporary in situ colloidal activated carbon (CAC) barrier. Worked examples are provided using public domain data from the FT‐02 fire‐fighting training site on the former Wurtsmith Air Force Base in Oscoda, MI. The projected CAC costs are approximately a third of the P&T costs over projection periods of 15–100 years ($ 7.2 M vs. $ 19 M at 30 years; 38%). Hydraulic containment and CAC remediation systems prevent the spread of per‐ and polyfluoroalkyl substance (PFAS)‐contaminated groundwater. Hydraulic containment works by extracting contaminated groundwater, removing the contamination using activated carbon or other means, and re‐injecting the cleaned groundwater. The arrangement of extraction and injection wells and the related groundwater pumping rates create a hydraulic barrier that captures and contains the PFAS plume. In situ CAC barriers work as passive underground filters. Micron‐scale particles of activated carbon are injected into contaminated aquifers using drilling equipment or injection wells. Once injected, the carbon particles attach to the soil. An in situ permeable barrier is installed across a contaminant plume through the injection of a number of points at suitable spacings. Groundwater flows through the barrier zone unimpeded while PFAS contamination is captured and contained by the activated carbon. The longevity of the barrier is determined by the quantity of carbon emplaced relative to the contaminant flux. Barriers are typically designed to last for years (decades), after which time, carbon re‐applications can be made, if required. Principal differences between the approaches are the scale of operation and maintenance requirements, and, for P&T, the bringing of PFAS‐impacted water above ground to treat. This generates a filtration medium that is contaminated with PFAS, and which therefore requires handling as a PFAS waste with attendant liability. Hydraulic containment is also an active technology (requiring external energy input) and requires the operation and maintenance of pumping and filtration equipment. In situ CAC barriers are passive (powered by natural groundwater flow) and have no operation and maintenance requirements. They do not bring PFAS‐impacted material above ground and do not generate waste. Performance data of the installed P&T hydraulic containment system were analyzed to estimate the time to remedial completion using the system alone. Data extrapolation supported by statistical analysis indicates clean‐up targets will not be reached within 100 years of pumping. It is not realistic for P&T to be regarded as a means of aquifer clean‐up as the aquifer will remain contaminated for the realistic future. Comparison is made between P&T and CAC on their common basis as containment approaches. The goal is to reduce the exposure of down‐gradient receptors to PFAS.

25 February 2019 in Groundwater Monitoring & Remediation
Verified
Journal Article
Open access
PDF file
JWJohn Wilson
John Wilson
JMJames C. Mills
James C. Mills
BWBarbara H. Wilson
Barbara H. Wilson
MFMark L. Ferrey
Mark L. Ferrey
DFDavid Freedman
David Freedman
DTDora Taggart
Dora Taggart
Monitored natural attenuation (MNA) is commonly used as a remedy for trichloroethene (TCE) in anaerobic groundwater; however, MNA has not been applied to TCE contamination in aerobic groundwater. Under aerobic conditions, bacteria initiate the degradation of many organic substances with oxygenase enzymes. Several of these enzymes are known to degrade TCE through a fortuitous reaction known as cometabolism. There are commercially available qPCR assays that can determine the number of gene copies of these enzymes. If the qPCR assay could be used to predict the first‐order rate constant for cometabolism of TCE, the qPCR assay could be used to screen sites to determine whether MNA was a plausible remedy for TCE contamination. This study reevaluated data from water samples that were collected from 19 wells on five sites in Minnesota, New York, and Utah. Data had previously been published on the rate constant for cometabolism of TCE in the water samples as determined by a 14C‐assay and the abundance of gene copies for five enzymes that cometabolize TCE as determined using a qPCR assay. The Michaelis‐Menten (Haldane) kinetic parameters for cometabolism of TCE and the abundance of DNA for the five oxygenase enzymes were used to predict the rate constant for cometabolism of TCE. The predicted rate constants were evaluated and validated by comparing them to the rate constants derived from the 14C‐assay. For predicted rate constants greater than 0.003 per year, the predicted rate constants agreed with the measured rate constants within a factor of three. The qPCR assay serves as a convenient screening tool to determine whether MNA is a plausible remedy for an aerobic plume of TCE.

12 January 2017 in Groundwater Monitoring & Remediation
Verified
Journal Article
Closed access
PDF file
TWTodd H. Wiedemeier
Todd H. Wiedemeier
BWBarbara H. Wilson
Barbara H. Wilson
MFMark L. Ferrey
Mark L. Ferrey
JWJohn Wilson
John Wilson

1 February 2024 in Remediation Journal
Verified
Journal Article
Open access
LHLinda C. Hall
Linda C. Hall
JWJohn Wilson
John Wilson
JBJeremy G. A. Birnstingl
Jeremy G. A. Birnstingl