Liyun Chang

Prof. Liyun Chang

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
Tsair-Fwu LEETsair-Fwu LEE
Tsair-Fwu LEE
SYShyh-An Yeh
Shyh-An Yeh
PCPei-Ju Chao
Pei-Ju Chao
LCLiyun Chang
Liyun Chang
CCChien-Liang Chiu
Chien-Liang Chiu
YHYu-Jie Huang
Yu-Jie Huang
Radiation-induced tinnitus is a side effect of radiotherapy in the inner ear for cancers of the head and neck. Effective dose constraints for protecting the cochlea are under-reported. The aim of this study is to determine the cochlea dose limitation to avoid causing tinnitus after head-and-neck cancer (HNC) intensity-modulated radiation therapy (IMRT). In total 211 patients with HNC were included; the side effects of radiotherapy were investigated for 422 inner ears in the cohort. Forty-nine of the four hundred and twenty-two samples (11.6 %) developed grade 2+ tinnitus symptoms after IMRT, as diagnosed by a clinician. The Late Effects of Normal Tissues–Subjective, Objective, Management, Analytic (LENT-SOMA) criteria were used for tinnitus evaluation. The logistic and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models were used for the analyses. The NTCP-fitted parameters were TD 50 = 46.31 Gy (95 % CI, 41.46–52.50), γ 50 = 1.27 (95 % CI, 1.02–1.55), and TD 50 = 46.52 Gy (95 % CI, 41.91–53.43), m = 0.35 (95 % CI, 0.30–0.42) for the logistic and LKB models, respectively. The suggested guideline TD 20 for the tolerance dose to produce a 20 % complication rate within a specific period of time was TD 20 = 33.62 Gy (95 % CI, 30.15–38.27) (logistic) and TD 20 = 32.82 Gy (95 % CI, 29.58–37.69) (LKB). To maintain the incidence of grade 2+ tinnitus toxicity <20 % in IMRT, we suggest that the mean dose to the cochlea should be <32 Gy. However, models should not be extrapolated to other patient populations without further verification and should first be confirmed before clinical implementation.

16 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TLTsair-Fwu Lee
Tsair-Fwu Lee
KSKuo-Chiang Sung
Kuo-Chiang Sung
PCPei-Ju Chao
Pei-Ju Chao
YHYu-Jie Huang
Yu-Jie Huang
JLJen-Hong Lan
Jen-Hong Lan
HTHui-Min Ting
Hui-Min Ting
To evaluate the relationships among patient characteristics, irradiation treatment planning parameters, and treatment toxicity of acute radiation dermatitis (RD) after breast hybrid intensity modulation radiation therapy (IMRT). The study cohort consisted of 95 breast cancer patients treated with hybrid IMRT. RD grade ≥2 (2+) toxicity was defined as clinically significant. Patient characteristics and the irradiation treatment planning parameters were used as the initial candidate factors. Prognostic factors were identified using the least absolute shrinkage and selection operator (LASSO)-based normal tissue complication probability (NTCP) model. A univariate cut-off dose NTCP model was developed to find the dose-volume limitation. Fifty-two (54.7%) of ninety-five patients experienced acute RD grade 2+ toxicity. The volume of skin receiving a dose >35 Gy (V35) was the most significant dosimetric predictor associated with RD grade 2+ toxicity. The NTCP model parameters for V35Gy were TV50 = 85.7 mL and γ50 = 0.77, where TV50 was defined as the volume corresponding to a 50% incidence of complications, and γ50 was the normalized slope of the volume-response curve. Additional potential predictive patient characteristics were energy and surgery, but the results were not statistically significant. To ensure a better quality of life and compliance for breast hybrid IMRT patients, the skin volume receiving a dose >35 Gy should be limited to 35 Gy should follow sparing tolerance and the inherent patient characteristics should be considered.

30 March 2021 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
SYShyh-An Yeh
Shyh-An Yeh
THTzer-Zen Hwang
Tzer-Zen Hwang
CWChih-Chun Wang
Chih-Chun Wang
CYChuen-Chien Yang
Chuen-Chien Yang
Ching-Feng LienChing-Feng Lien
Ching-Feng Lien
Tsair-Fwu LEETsair-Fwu LEE
Tsair-Fwu LEE
Nasopharyngeal cancer shows a good response to intensity-modulated radiotherapy. However, there is no clear evidence for the benefits of routine use of image-guided radiotherapy. The purpose of this study was to perform a retrospective investigation of the treatment outcomes, treatment-related complications and prognostic factors for nasopharyngeal cancer treated with intensity-modulated radiotherapy and image-guided radiotherapy techniques. Retrospective analysis was performed on 326 consecutive nasopharyngeal cancer patients treated between 2004 and 2015. Potentially significant patient-related and treatment-related variables were analyzed. Radiation-related complications were recorded. The 5-year overall survival and disease-free survival rates of these patients were 77.9% and 70.5%, respectively. Age, AJCC (American Joint Committee on Cancer) stage, retropharyngeal lymphadenopathy, treatment interruption and body mass index were independent prognostic factors for overall survival. Age, AJCC stage, retropharyngeal lymphadenopathy, image-guided radiotherapy and body mass index were independent prognostic factors for disease-free survival. In conclusion, intensity-modulated radiotherapy significantly improves the treatment outcomes of nasopharyngeal cancer. With the aid of image-guided radiotherapy, the advantage of intensity-modulated radiotherapy might be further amplified.

31 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
LCLiyun Chang
Liyun Chang
SYShyh-An Yeh
Shyh-An Yeh
SHSheng-Yow Ho
Sheng-Yow Ho
HDHueisch-Jy Ding
Hueisch-Jy Ding
PCPang-Yu Chen
Pang-Yu Chen
Tsair-Fwu LEETsair-Fwu LEE
Tsair-Fwu LEE
To achieve a dose distribution conformal to the target volume while sparing normal tissues, intensity modulation with steep dose gradient is used for treatment planning. To successfully deliver such treatment, high spatial and dosimetric accuracy are crucial and need to be verified. With high 2D dosimetry resolution and a self‐development property, the Ashland Inc. product EBT3 Gafchromic film is a widely used quality assurance tool designed especially for this. However, the film should be recalibrated each quarter due to the “aging effect,” and calibration uncertainties always exist between individual films even in the same lot. Recently, artificial neural networks (ANN) are applied to many fields. If a physicist can collect the calibration data, it could be accumulated to be a substantial ANN data input used for film calibration. We therefore use the Keras functional Application Program Interface to build a hierarchical neural network (HNN), with the inputs of net optical densities, pixel values, and inverse transmittances to reveal the delivered dose and train the neural network with deep learning. For comparison, the film dose calculated using red‐channel net optical density with power function fitting was performed and taken as a conventional method. The results show that the percentage error of the film dose using the HNN method is less than 4% for the aging effect verification test and less than 4.5% for the intralot variation test; in contrast, the conventional method could yield errors higher than 10% and 7%, respectively. This HNN method to calibrate the EBT film could be further improved by adding training data or adjusting the HNN structure. The model could help physicists spend less calibration time and reduce film usage.

1 March 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LCLiyun Chang
Liyun Chang
SHSheng-Yow Ho
Sheng-Yow Ho
Tsair-Fwu LEETsair-Fwu LEE
Tsair-Fwu LEE
SYShyh-An Yeh
Shyh-An Yeh
HDHueisch-Jy Ding
Hueisch-Jy Ding
PCPang-Yu Chen
Pang-Yu Chen

1 May 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YCYuan-Po Chen
Yuan-Po Chen
SYShyh-An Yeh
Shyh-An Yeh
YHYung-Hui Huang
Yung-Hui Huang
LCLiyun Chang
Liyun Chang
CKChung-Ming Kuo
Chung-Ming Kuo
HDHueisch-Jy Ding
Hueisch-Jy Ding