Corneal sensitivity is an important indicator of corneal health and innervation. Corneal hypoesthesia may be an early indicator of corneal diseases such as neurotrophic keratopathy. Various instruments have been used to measure corneal sensitivity, the first being the Cochet–Bonnet aesthesiometer. Over the years, new devices employing different stimuli have been developed, such as the gas-based Belmonte aesthesiometer, the Swiss liquid-jet aesthesiometer, and the most recently released corneal Brill aesthesiometer. In this review, the progress and advancement of aesthesiometers since their introduction is described. The mechanism, advantages, and disadvantages of these aesthesiometers are discussed and compared. We also report the relationship between corneal sensitivity and corneal innervation in various conditions, including diabetes mellitus, Fuchs’ endothelial dystrophy, dry eye disease, glaucoma, keratoconus, herpes simplex keratitis, post-refractive surgery, and ocular graft-versus-host disease. Through this review, we aim to highlight the importance of the assessment of corneal sensitivity and innervation in the diagnosis, treatment, and monitoring of anterior and posterior segment ocular disorders.
Terahertz (THz) waves reside in the electromagnetic spectrum between the microwave and infrared bands. In recent decades, THz technology has demonstrated its potential for biomedical applications. With the highly unique characteristics of THz waves, such as the high sensitivity to water and optimal spatial resolution coupled with the characteristics of the human cornea, such as its high water content, THz technology has been explored as a potential modality to assess corneas and corneal diseases. This systematic review provides an overview of the characteristics of THz waves, the safety profile of THz technology in the field of ophthalmology, and its clinical applications, including the objective evaluation of the corneal hydration, tear film, dry eye disease, corneal endothelium, corneal elasticity, and scarring. The paper also presents our viewpoint on the present challenges and future directions of THz technology prior to its broader integration into clinical practice.
Purpose: To investigate and compare the quality of life (QoL) and symptomatology between neuropathic corneal pain (NCP) and dry eye disease (DED). Methods: We recruited 150 patients, comprising 50 patients with NCP and 100 patients with DED. Patients’ symptoms and QoL were evaluated using the Ocular Pain Assessment Survey and Ocular Surface Disease Index questionnaires. Ocular surface assessments were also performed. Results: Patients with NCP demonstrated significantly lower Oxford and National Eye Institute scores for ocular surface and corneal staining, respectively, and a better tear break-up time than patients with DED. However, patients with NCP reported significantly worse scores on most of the Ocular Pain Assessment Survey questions and significantly more severe overall pain (P = 0.019), maximal and average ocular pain and nonocular pain (all P < 0.05). The NCP group reported significantly worse QoL in all aspects of daily living (all P < 0.001). Patients with NCP spent more time thinking about their eye pain and reported significantly higher pain intensities than patients with DED when exposed to chemical and mechanical stimuli (all P ≤ 0.008). Burning sensation and photophobia were significantly more frequent in patients with NCP (P = 0.032 and P = 0.012, respectively). Similarly, the NCP group reported significantly worse total Ocular Surface Disease Index scores, significantly more frequent vision-related function impairment and painful or sore eyes than the DED group (P = 0.029, P = 0.031, and P = 0.014, respectively). Conclusions: Compared with DED, NCP is more debilitating, leading to more severe and frequent symptoms, and greater negative impact on all aspects of QoL.
The aim of our study is to investigate the feasibility and outcomes of using a femtosecond laser (FSL) platform (Ziemer LDV Z8) for deep anterior lamellar keratoplasty (DALK), enabling the creation of mushroom-shaped graft–host junctions, lamellar cuts, and intrastromal tunnels, to facilitate the big bubble, in one step. We included wet lab experiments on nine porcine eyes to assess the laser accuracy and cuts depth using an anterior segment (AS) OCT. This was followed by an interventional prospective case series on 10 eyes with variant corneal pathologies. The Z8 system, with in-built intraoperative optical coherence tomography (iOCT), guided corneal scans and directed the cuts. ASOCT showed visible mushroom configurations, lamellar cuts, and tunnels. Deviations from the target were 1.6%, 2.6%, and 3.5%. Anterior lamellar removal was easy in all clinical cases, including corneal scarring. The intrastromal tunnel was found at the preset location and the mushroom configuration was acquired. A big bubble was achieved in all cases. Type 1, 2, and 3 bubbles were formed in eight, one, and one case, respectively. We describe a new approach to DALK in which the in-built iOCT-guided FSL enables safe, precise, controlled, and reproducible desired cuts in one step. The preliminary clinical outcomes were favorable.
Purpose: To profile tear cytokine changes in Allogeneic Hematopoietic Stem Cell Transplant (HSCT) patients after instillation of daily topical cyclosporine-A 0.1% cationic emulsion. Methods: Participants in a longitudinal study were given cyclosporine eyedrops daily from 3 to 5 weeks before and 3 months, 6 months, and 12 months post-HSCT. The outcomes included tear cytokine concentration assayed by the Proximity Extension Assay O-linked target 96 platform. The patients were divided into two groups: Group 1 (n = 8 conjunctival CD4 cells responding to cyclosporine) and Group 2 (n = 5 conjunctival CD4 cells not suppressed after cyclosporine, where patients were non-compliant with cyclosporine). All participants had a standardized clinical examination, including meibomian gland evaluation and tear breakup times. Results: The levels of 38 cytokines/chemokines showed significant changes (p < 0.05) over time, and in many, the elevation was marked at one year. These include gamma-interferon, CXCL9, CCL3, and CCL4 (all p < 0.0001). For gamma-interferon, there was significant interaction between group and time at 1 year (p = 0.022), where the cytokine was significantly suppressed in Group 1. Four other cytokines showed significant group and time interaction at 1 year: FGF23, FGF5, LIFR, and Enrage (all p < 0.05). All patients had either withdrawal or a reduction in systemic immunomodulation between 6 months and 1 year. We found several cytokines to be associated with changes in tear osmolarity or symptom scores. Conclusions: HSCT induces significant elevation of 38 tear cytokines/chemokines even without the occurrence of ocular graft-versus-host disease when systemic immunosuppression is reduced within the first year. Topical daily cyclosporine eyedrops can reduce some pro-inflammatory tear cytokines.
Corneal nerves (CNs) are essential to maintain corneal epithelial integrity and ocular surface homeostasis. In vivo confocal microscopy (IVCM) enables the acquisition of high-resolution visualization of CNs, allowing visualization on a microscopic level. Traditionally, CN images must be analyzed by manual examination, which is time consuming and labor intensive. Artificial intelligence (AI) has facilitated reliable analysis of CN parameters, allowing for automatic and semiautomatic analysis of CNs. These include the identification, segmentation, and quantitative analysis of various CN parameters. This review summarizes the applications of AI-driven, automatic, and semiautomatic models in the CN analysis of IVCM images while also focusing on their diagnostic relevance in dry eye disease (DED) and neuropathic corneal pain (NCP). Recent advancements in AI have transformed IVCM image analysis by improving reproducibility and reducing operator dependency and time. The AI-based algorithm has been demonstrated to have good performance and sensitivity to identify and quantify the CN metrics. AI has also been utilized to improve the diagnostic accuracy of DED with IVCM scans, involving multiple portions of the CNs, such as the inferior whorl region. When employed with IVCM images of patients with NCP, AI-assisted identification of microneuromas and changes in CN metrics has provided an improvement in diagnostic accuracy. Despite promising advances and outcomes, the widespread implementation of these AI models in CN image analysis requires large-scale validation. Future integration of multimodal AI algorithms remains a promising endeavor to enhance diagnostic accuracy and disease stratification.