Li Rui

Mr. Li Rui

orcid

Research Focus & Metrics

Representative Publications

View All Publications
15 April 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYuhang Wang
Yuhang Wang
LRLi Rui
Li Rui
XSXuefeng Song
Xuefeng Song
JTJunye Tong
Junye Tong
THTianyuan Hou
Tianyuan Hou
YWYuan Wang
Yuan Wang
The sol adhesion method prepared an all-solid ultralow noise electric field sensor. Compared with the sintering method, electrolysis method, and ball milling method, the content of Ag (silver) and AgCl (silver chloride) stays at a high-level amount, the mixture is more uniform and there are no impurities introduced in the fabrication process. Some experiments were designed to characterize the basic properties and electrochemical characteristics of the electrode. Scanning electron microscope (SEM) shows the produced Ag/AgCl (silver and silver chloride) has small particle sizes and a large contact area. The potential drifts of electrodes are less than $15~\mu $ V. The self-potential is less than $80~\mu $ V. Self-noise of the electrode is 1.99 nV/ $\surd $ Hz@1 Hz. Meanwhile, the electrode responds well to electric field signals from 0.1 Hz to 3 kHz and can detect small amplitude signals to 2 mV without distortion. The electrode has the advantages of low impedance, low noise, high sensitivity, and high stability. The self-potential test showed the Ag/AgCl electrodes spent less than 20 min to reach stability is at least three times faster than that of Cu, Ag, Pb/PbCl, and stainless-steel electrodes. Stability potential and range drift are at least 98% and 93% lower than that of other electrodes. In the telluric test, the signal amplitude is at least four times of Ag and Pb/PbCl electrodes. In the marine test, the signal amplitude value is 4 mV level with the noise amplitude value is 0.06 mV level. It shows the good performance of the electrodes. This study is of great significance in accurately measuring marine and telluric electric fields.

1 July 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
YWYuhang Wang
Yuhang Wang
真朴真铭 朴
真铭 朴
LRLi Rui
Li Rui
THTianyuan Hou
Tianyuan Hou
CLChang Sheng Liu
Chang Sheng Liu
YXYi Xin
Yi Xin
This paper presents an ultra-low noise nanoporous Ag/AgCl electric field sensor fabricated using a sol in situ composite method, aiming to address the issues of high noise and significant drift encountered in traditional electric field sensors during low-frequency signal measurements. By utilizing polyvinylpyrrolidone (PVP) sol to regulate the nucleation process of AgCl and combining it with nano-silver powder, nanoscale Ag/AgCl particles were prepared. Through the use of NaCl as a pore-forming agent, an electrode with a porous structure was developed. A double-layer porous semi-permeable membrane encapsulation structure is employed, which protects the electrode from external environmental damage without compromising its performance, thereby improving its stability and lifespan. Experimental results demonstrate that the electrode exhibits a low source resistance of 0.13 Ω, the 24-h drift of less than 12 μV, and the self-noise of 0.874 nV/√Hz@1 Hz, with the working frequency band ranging from 0.1 Hz to 100 kHz, showcasing excellent frequency response and stability. Field tests in electrical prospecting further validated the electrode's high accuracy and reliability in measuring apparent resistivity, apparent polarizability, and spontaneous potential. This technological breakthrough provides robust technical support for deep resource exploration and long-term geoelectric field monitoring.

3 October 2023 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Closed access
PDF file
YXYi Xin
Yi Xin
LRLi Rui
Li Rui
XSXuefeng Song
Xuefeng Song
YWYuqi Wang
Yuqi Wang
HZHanshuo Zhang
Hanshuo Zhang
ZCZhiying Chen
Zhiying Chen

7 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
YWYuhang Wang
Yuhang Wang
LRLi Rui
Li Rui
THTianyuan Hou
Tianyuan Hou
真朴真铭 朴
真铭 朴
YLYanxin Lv
Yanxin Lv
YXYi Xin
Yi Xin
To solve the problems of carbon fiber (CF) electrodes, including poor frequency response and large potential drift, CFs were subjected to a roughening pretreatment process combining thermal oxidation and electrochemical anodic oxidation and then modified with Ag nanoparticles (AgNPs) using electroplating to prepare a CF electric field sensor. The surface morphology of the as-prepared AgNP-CF electric field sensor was characterized via optical microscopy, scanning electron microscopy, XPS, and energy-dispersive spectroscopy, and its impedance, polarization drift, self-noise, and temperature drift values were determined. Results show that the surface modification of the AgNP-CF electric field sensor is uniform, and its specific surface area is considerably increased. The electrode potential drift, characteristic impedance, self-noise, and temperature drift are 52.1 µV/24 h, 3.6 Ω, 2.993 nV/√Hz@1 Hz, and less than 70 µV/°C, respectively. Additionally, the AgNP-CF electric field sensor demonstrates low polarization and high stability. In field and simulated ocean tests, the AgNP-CF electrode exhibits excellent performance in the field and underwater environments, which renders it promising for the measurement of the ocean and geoelectric fields owing to its advantages, such as low noise and high stability.