X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.
Ice crystallization in supercooled water is a complex phenomenon with far-reaching implications across scientific disciplines, including cloud formation physics and cryopreservation. Experimentally studying such complexity can be a highly data-driven and data-hungry endeavor because of the need to record rare events that cannot be triggered on demand. Here, we describe such an experiment comprising 561 million images of X-ray free-electron laser (XFEL) diffraction patterns (2.3 raw data) spanning the disorder-to-order transition in micrometer-sized supercooled water droplets. To effectively analyze these patterns, we propose a data reduction (i.e., coarse-graining) and dimensionality reduction (i.e., principal component analysis) strategy. We show that a simple set of criteria on this reduced dataset can efficiently classify these patterns in the absence of reference diffraction signatures, which we validated using more precise but computationally expensive unsupervised machine learning techniques. For hit-finding, our strategy attained 98% agreement with our cross-validation. We speculate that these strategies may be generalized to other types of large high-dimensional datasets generated at high-throughput XFEL facilities.
Free-standing thin liquid films offer a convenient way to probe matter in solution without a substrate, where a small sample thickness is required. The production of thin films in a vacuum environment is required for probes that cannot penetrate through a surrounding gas or in cases where the gas produces problematic background noise. Nozzles that produce continuously flowing liquid sheet jets have been employed recently for scattering and spectroscopy measurements at X-ray free-electron lasers (XFELs). However, their performance in vacuum with aqueous samples is complicated by high freezing susceptibility due to a strong evaporative cooling effect. Here, we introduce a vacuum-compatible gas-impinging liquid sheet jet nozzle capable of generating sub-100 nm aqueous films. The introduction of a second axisymmetric helium gas sheath surrounding the liquid orifice enables seamless startup and shutdown within a vacuum environment. We investigated the sheet geometry dependence under varying flow conditions and liquid viscosity and demonstrated its viability for X-ray scattering measurements at a high-repetition-rate XFEL source. Finally, we present potential strategies for reducing sample consumption. Our findings confirm that this nozzle exhibits simplified vacuum operation and may help promote the broader utilization of liquid sheet jets for several experimental applications.