To address the wear life prediction challenge of Guide Cones in passive compliant connectors under dynamic loads within specialized equipment, this study proposes a dynamic wear modeling and life assessment method based on the improved Archard model. Through integrated theoretical modeling, finite element simulation, and experimental validation, we establish a bidirectional coupling framework analyzing dynamic contact mechanics and wear evolution. By developing phased contact state identification criteria and geometric constraints, a transient load calculation model is established, revealing dynamic load characteristics with peak contact forces reaching 206.34 N. A dynamic contact stress integration algorithm is proposed by combining Archard’s theory with ABAQUS finite element simulation and ALE adaptive meshing technology, enabling real-time iterative updates of wear morphology and contact stress. This approach constructs an exponential model correlating cumulative wear depth with docking cycles (R2 = 0.997). Prototype experiments demonstrate a mean absolute percentage error (MAPE) of 14.6% between simulated and measured wear depths, confirming model validity. With a critical wear threshold of 0.8 mm, the predicted service life reaches 45,270 cycles, meeting 50-year operational requirements (safety margin: 50.9%). This research provides theoretical frameworks and engineering guidelines for wear-resistant design, material selection, and life evaluation in high-reliability automatic docking systems.
Rapid transfer of large cryogenic models between ambient and cryogenic environments causes severe thermal shocks to the dry air system, threatening dew-point stability and equipment safety. Using CFD, this study builds a 1:1 model of a cryogenic transport isolation system, including the dry hall, model carrier, temperature-conditioning room, and test section plenum. Three scenarios are analyzed: static suspension, descent to the temperature-conditioning room, and descent to the test section plenum. The effects of descent speed (1.2 vs. 2.5 m/min) and makeup air flow (0–12,500 m3/h) on temperature distribution and cable safety are examined. Results show that after 10 min of static suspension, the carrier interior averages 192 K with strong stratification and a minimum of 170 K. During descent, higher speed and larger air flow improve thermal retention. At 2.5 m/min and 10,000 m3/h, cable-adjacent gas stays above −60 °C. For the plenum, descent-matched displacement ventilation (e.g., 6000 m3/h for 1.2 m/min) keeps both the cable and the plug-in unit safe. Including the cable thermal capacity gives a smaller actual temperature drop than conservative gas-temperature estimates. This work provides numerical guidance for dry system design, operation optimization, and cryogenic protection during rapid model transfer.