Luke P. Lee

Prof. Dr. Luke P. Lee

University of California, Berkeley, QB3, 408C Stanley Hall, Berkeley, CA 94720-1762, USA

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2007 in Biotechnology and Bioengineering
Verified
Journal Article
Open access
PDF file
PLPhilip J. Lee
Philip J. Lee
PHPaul J. Hung
Paul J. Hung
LLLuke P. Lee
Luke P. Lee
Primary hepatocytes represent a physiologically relevant model for drug toxicity screening. Here, we created a biologically inspired artificial liver sinusoid with a microfluidic endothelial‐like barrier having mass transport properties similar to the liver acinus. This unit consisted of a cord of hepatocytes (50 × 30 × 500 µm) fed by diffusion of nutrients across the microfluidic endothelial‐like barrier from a convective transport vessel (10 nL/min). This configuration sustained rat and human hepatocytes for 7 days without an extracellular matrix (ECM) coating. Experiments with the metabolism mediated liver toxicant diclofenac showed no hepatotoxicity after 4 h and an IC50 of 334 ± 41 µM after 24 h. Biotechnol. Bioeng. 2007; 97: 1340–1346.

30 October 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
FMFrank B. Myers
Frank B. Myers
LLLuke P. Lee
Luke P. Lee
Despite a growing focus from the academic community, the field of microfluidics has yet to produce many commercial devices for point-of-care (POC) diagnostics. One of the main reasons for this is the difficulty in producing low-cost, sensitive, and portable optical detection systems. Although electrochemical methods work well for certain applications, optical detection is generally regarded as superior and is the method most widely employed in laboratory clinical chemistry. Conventional optical systems, however, are costly, require careful alignment, and do not translate well to POC devices. Furthermore, many optical detection paradigms such as absorbance and fluorescence suffer at smaller geometries because the optical path length through the sample is shortened. This review examines the innovative techniques which have recently been developed to address these issues. We highlight microfluidic diagnostic systems which demonstrate practical integration of sample preparation, analyte enrichment, and optical detection. We also examine several emerging detection paradigms involving nanoengineered materials which do not suffer from the same miniaturization disadvantages as conventional measurements.

11 January 2021 in Nature Methods
Verified
Journal Article
Closed access
PDF file
YCYuchao Chen
Yuchao Chen
QZQingfu Zhu
Qingfu Zhu
LCLiming Cheng
Liming Cheng
YWYong Wang
Yong Wang
MLMeng Li
Meng Li
FLFei Liu
Fei Liu

3 March 2017 in Science Advances
Verified
Journal Article
Open access
PDF file
EYErh-Chia Yeh
Erh-Chia Yeh
CFChi-Cheng Fu
Chi-Cheng Fu
LHLucy Hu
Lucy Hu
RTRohan Thakur
Rohan Thakur
JFJeffrey Feng
Jeffrey Feng
LLLuke P. Lee
Luke P. Lee
Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps. First, we prepatterned the amplification initiator [magnesium acetate (MgOAc)] on the chip to enable digital nucleic acid amplification. Second, a simplified sample preparation step is demonstrated, where the plasma is separated autonomously into 224 microwells (100 nl per well) without any hemolysis. Furthermore, self-powered microfluidic pumping without any external pumps, controllers, or power sources is accomplished by an integrated vacuum battery on the chip. This simple chip allows rapid quantitative digital nucleic acid detection directly from human blood samples (10 to 105 copies of methicillin-resistant Staphylococcus aureus DNA per microliter, ~30 min, via isothermal recombinase polymerase amplification). These autonomous, portable, lab-on-chip technologies provide promising foundations for future low-cost molecular diagnostic assays.

8 December 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
IDIvan K. Dimov
Ivan K. Dimov
LBLourdes Basabe-Desmonts
Lourdes Basabe-Desmonts
JGJose L. Garcia-Cordero
Jose L. Garcia-Cordero
BRBenjamin M. Ross
Benjamin M. Ross
ARAntonio Ricco
Antonio Ricco
LLLuke P. Lee
Luke P. Lee
We present a self-powered integrated microfluidic blood analysis system (SIMBAS) that does not require any external connections, tethers, or tubing to deliver and analyze a raw whole-blood sample. SIMBAS only requires the user to place a 5 μL droplet of whole-blood at the inlet port of the device, whereupon the stand-alone SIMBAS performs on-chip removal of red and white cells, without external valving or pumping mechanisms, followed by analyte detection in platelet-containing plasma. Five complete biotin–streptavidin sample-to-answer assays are performed in 10 min; the limit of detection is 1.5 pM. Red and white blood cells are removed by trapping them in an integral trench structure. Simulations and experimental data show 99.9% to 100% blood cell retention in the passive structure. Powered by pre-evacuation of its PDMS substrate, SIMBAS' guiding design principle is the integration of the minimal number of components without sacrificing effectiveness in performing rapid complete bioassays, a critical step towards point-of-care molecular diagnostics.

18 November 2005 in Science
Verified
Journal Article
Closed access
PDF file
LLLuke P. Lee
Luke P. Lee
RSRobert Szema
Robert Szema
Observing systems in nature has inspired humans to create technological tools that allow us to better understand and imitate biology. Biomimetics, in particular, owes much of its current development to advances in materials science and creative optical system designs. New investigational tools, such as those for microscopic imaging and chemical analyses, have added to our understanding of biological optics. Biologically inspired optical science has become the emerging topic among researchers and scientists. This is in part due to the availability of polymers with customizable optical properties and the ability to rapidly fabricate complex designs using soft lithography and three-dimensional microscale processing techniques.