Excessive levels of Pb2+ and Cd2+ in seawater pose significant combined toxicity to marine organisms, resulting in harmful effects and further threatening human health through biomagnification in the food chain. Traditional methods for detecting marine Pb2+ and Cd2+ rely on laboratory analyses, which are hindered by limitations such as sample degradation during transport and complex operational procedures. In this study, we present an electrochemical sensor based on intelligent mobile detection devices. By combining G-COOH-MWCNTs/ZnO with differential pulse voltammetry, the sensor enables the efficient, simultaneous detection of Pb2+ and Cd2+ in seawater. The G-COOH-MWCNTs/ZnO composite film is prepared via drop-coating and is applied to a glassy carbon electrode. The film is characterized using cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy, while Pb2+ and Cd2+ are quantified using differential pulse voltammetry. Using a 0.1 mol/L sodium acetate buffer (pH 5.5), a deposition potential of −1.1 V, and an accumulation time of 300 s, a strong linear correlation was observed between the peak response currents of Pb2+ and Cd2+ and their concentrations in the range of 25–450 µg/L. The detection limits were 0.535 µg/L for Pb2+ and 0.354 µg/L for Cd2+. The sensor was applied for the analysis of seawater samples from Maowei Sea, achieving recovery rates for Pb2+ ranging from 97.7% to 103%, and for Cd2+ from 97% to 106.1%. These results demonstrate that the sensor exhibits high sensitivity and stability, offering a reliable solution for the on-site monitoring of heavy metal contamination in marine environments.
This study combines an experimental semi-physical simulation model of an electric propulsion tugboat with four different neural networks to create a real-time simulation model for forecasting total power loads with small samples. The results of repeated experiments demonstrate that the BP neural network effectively forecasts the power load. Subsequently, addressing the limitations of traditional BP neural networks, an optimization approach employing an enhanced particle swarm algorithm and attention mechanism was developed, thereby improving the model’s prediction accuracy and robustness. The experiment shows that the improved prediction model achieves an R2 value of 97.42%, demonstrating its effectiveness in forecasting changes in the short-term power load of ships as parameters change. In actual operation, ships can allocate power reasonably and in a timely manner according to the load forecast results, thereby improving the efficiency of the power grid.
7,12-Dimethylbenzo[a]anthracene (DMBA-7,12), a highly toxic and environmentally persistent polycyclic aromatic hydrocarbon (PAH), poses significant threats to marine biodiversity and human health due to its bioaccumulation through the food chain. Conventional chromatographic methods, while achieving comparable detection limits, are hindered by the need for expensive instrumentation and prolonged analysis times, rendering them unsuitable for rapid on-site monitoring of DMBA-7,12 in marine environments. Therefore, the development of novel, efficient detection techniques is imperative. In this study, we have successfully developed an electrochemical immunosensor based on a polydopamine (PDA)–chitosan (CTs) composite interface to overcome existing technical limitations. PDA provides a robust scaffold for antibody immobilization due to its strong adhesive properties, while CTs enhances signal amplification and biocompatibility. The synergistic integration of these materials combines the high efficiency of electrochemical detection with the specificity of antigen–antibody recognition, enabling precise qualitative and quantitative analysis of the target analyte through monitoring changes in the electrochemical properties at the electrode surface. By systematically optimizing key experimental parameters, including buffer pH, probe concentration, and antibody loading, we have constructed the first electrochemical immunosensor for detecting DMBA-7,12 in seawater. The sensor achieved a detection limit as low as 0.42 ng/mL. In spiked seawater samples, the recovery rates ranged from 95.53% to 99.44%, with relative standard deviations (RSDs) ≤ 4.6%, demonstrating excellent accuracy and reliability. This innovative approach offers a cost-effective and efficient solution for the in situ rapid monitoring of trace carcinogens in marine environments, potentially advancing the field of marine pollutant detection technologies.
1-Aminopyrene, as a transformation product of the priority pollutant 1-nitropyrene, has raised increasing concerns due to its carcinogenic, mutagenic, and bioaccumulative properties in marine environments. A rapid and sensitive method for trace 1-aminopyrene detection in seawater is essential for marine environmental monitoring and public health protection. In this paper, a novel electrochemical immunosensor was fabricated based on an NH2-functionalized multi-walled carbon nanotubes-chitosan (NH2-MWCNTs/CS) nanocomposite film loaded with anti-1-aminopyrene antibody on a glassy carbon electrode. The NH2-MWCNTs/CS composite served as a conductive and biocompatible matrix that facilitated interfacial electron transfer and provided a suitable surface for adsorption-based antibody immobilization. Potassium ferricyanide was employed as an electrochemical probe to generate voltammetric signals, and the immune response was investigated by differential pulse voltammetry. Under optimized experimental conditions, the peak current change was inversely proportional to the 1-aminopyrene concentration in the range of 0.5 ng·mL−1 to 110 ng·mL−1, with a detection limit of 0.36 ng·mL−1. The immunosensor demonstrated good selectivity, stability, and anti-interference capability in complex sample matrices. It was successfully applied to the determination of 1-aminopyrene in real seawater samples, with recovery rates ranging from 97.53% to 99.30% and relative standard deviations below 0.92%. The results indicate that the proposed immunosensor offers a simple, cost-effective, and environmentally friendly alternative to conventional chromatographic methods, and holds great potential for on-site monitoring of trace PAH metabolites in marine environments.
In this study, an electrochemical sensor based on a graphitized carboxylated multi-walled carbon nanotube/polyaniline (G-COOH-MWCNTs/PANI) composite was developed for the highly sensitive detection of Pb2+ in seawater. A G-COOH-MWCNTs/PANI composite dispersion was prepared via a solution blending method and subsequently drop-cast onto a glassy carbon electrode (GCE) to fabricate the modified electrode. Differential pulse anodic stripping voltammetry (DPASV) was employed for the quantitative determination of Pb2+. The morphology of the composite was characterized by scanning electron microscopy (SEM), while the electrochemical behavior of the modified electrode was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Critical experimental parameters, including the type and pH of the supporting electrolyte, deposition potential, deposition time, and loading amount of the composite film, were systematically optimized. In addition, the optimal concentration ratio of G-COOH-MWCNTs to PANI was determined using an orthogonal experimental design. Under the optimized experimental conditions, the proposed sensor exhibited a linear response toward Pb2+ over the concentration range of 25–220 μg/L, with the regression equation Ip = 2.757C + 4.316 (R2 = 0.997). The limit of detection (LOD), calculated at a signal-to-noise ratio (S/N) of 3, was 0.0337 μg/L. The sensor also demonstrated excellent reproducibility (relative standard deviation, RSD = 1.7%), satisfactory anti-interference capability, and good long-term stability, retaining 94.1% of its initial response after 35 days of storage. Spike recovery experiments using real seawater samples yielded recoveries ranging from 96.73% to 99.73%, with RSD values below 3%, indicating excellent accuracy and precision in complex seawater matrices. These results demonstrate that the proposed sensor enables accurate determination of Pb2+ in seawater without complicated sample pretreatment and exhibits considerable potential for applications in marine environmental monitoring of heavy metal contamination.