This paper presents the development of a lumped-parameter model of multistory framed shear buildings supporting rigid blocks with the possibility to slide. After favorably comparing with results from finite-element analyses and shake table tests, the model was used to assess design provisions in regard to the treatment of live load as seismic weight. It was found that using the minimum live load percentage in current design standards may lead to unconservative drift estimates for buildings supporting heavy and nearly permanent live load objects and structures that are (1) designed for higher values, (2) located in regions of low-to-moderate seismic risk, or (3) base isolated. Results from a parametric study led to a design expression that allows determining the portion of the expected live load that is effective as seismic weight on the structure as a function of the object/floor interface’s friction coefficient and the maximum floor acceleration of the building alone. The adequacy of the design expression was confirmed through three-dimensional finite-element analyses of two- and four-story buildings supporting live load objects that could slide.
This technical note presents charts that allow bridge engineers to quickly estimate the minimum footing dimensions, as controlled by the nominal (or ultimate) bearing capacity of the supporting soil, to develop the biaxial plastic moment capacity of corresponding columns. The design aids are applicable to rectangular, circular, and oval reinforced concrete (RC) columns with cross-sectional dimensions of up to 2.44 m (8 ft), longitudinal reinforcement ratios from 1 to 2%, transverse reinforcement ratios from 0.4 to 1.2%, concrete compressive strengths ( ) from 28 (4) to 42 MPa (6 ksi), and axial load levels between 0.05 and 0.2 .
Lumped plasticity models available in commercial software offer a limited resolution of damage distribution along structural members. This study presents an open-source workflow that combines force-based fiber elements in OpenSeesPy with automated 3D post-processing for visualizing distributed plasticity in reinforced concrete piles. A 60 cm diameter pile subjected to monotonic lateral loading is analyzed using both SAP2000’s default plastic hinges and OpenSeesPy fiber sections (Concrete02/Steel02). Although the fiber model incurs a runtime approximately 2.5 times greater, it captures the gradual spread of yielding and deterioration with improved fidelity. The presented workflow includes Python routines for interactive stress–strain visualization, facilitating the identification of critical sections and verification of strain limits. This approach offers a computationally feasible alternative for performance-based analysis with enhanced insight into member-level behavior. Because the entire workflow—from model definition through post-processing—is fully scripted in Python, any change to geometry, materials, or loading can be re-run in seconds, dramatically reducing the time taken to execute sensitivity analyses.
The magnitude 8.8 earthquake of February 2010 in Chile dealt a heavy blow to the 600-meter (2,000-ft) wharf structure at Berths 1, 2, and 3 of the San Vicente Terminal Internacional in the Biobio region of Chile. Earthquake-induced liquefaction and lateral spreading in the upland fill and wharf slope resulted in permanent wharf lateral deflections in excess of 600 mm (24 in), along with associated damage to concrete piling and pile-to-cap connections. This paper presents the post-earthquake repair and rehabilitation program for the wharf structure. The proposed rehabilitation strategy consisted of two phases: first, a structural assessment of the post-earthquake conditions with recommendations for short-term repairs and restrictions on operating criteria, followed by a structural retrofit program designed to stiffen the existing structure and provide a new lateral-force resisting system. An innovative approach to the seismic retrofit was used, which incorporates a combination of new plumb piles behind the wharf with ground improvement to ensure ample lateral strength and ductility capacity of the structure. The wharf retrofit also included a new apron structure in front of the wharf, designed to improve the local stability of existing slender piling (impacted by P-delta effects), with the added benefit of providing support for future crane rail installation and increased dredge depth. Finally, a 200-meter (656-ft) finger pier extension was included in the program, bringing the structurally retrofitted 4-berth system to a total combined 800 meters in length, designed to the most current seismic design standards.