Yu Yu

Dr. Yu Yu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYISU ZHANG
YISU ZHANG
KWKai Wang
Kai Wang
WYWei Yue
Wei Yue
SLShuangkui Liu
Shuangkui Liu
YYYu Yu
Yu Yu
Xin YeXin Ye
Xin Ye
Underwater spectral detection plays an important role in the study of the underwater environment, ecology, oceanography, and environmental monitoring. A kind of underwater spectral radiometer that can observe the distribution of underwater spectral radiation bidirectionally has been developed. The flat-field concave holographic grating is used as the only optical component, the optical design parameters are optimized, and the system is miniaturized. The mechanism of stray light generation in the spectrometer is studied, and a method of suppressing stray light is proposed and simulated. The level of stray light in the system is suppressed to the order of 10−4, the signal-to-noise ratio of the system is improved, and the ability to detect weak light is enhanced. The wavelength calibration experiment was completed, and the experimental results show that the wavelength resolution of the underwater spectral radiometer is better than 3 nm. Finally, the quantitative relationship between spectral irradiance and digital output is obtained through radiation in the calibration of the system.

14 August 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XLXiao Liang
Xiao Liang
YZYaopu Zou
Yaopu Zou
CHchangpei han
changpei han
LLLibing Li
Libing Li
YZYuanshu Zhang
Yuanshu Zhang
YYYu Yu
Yu Yu
The Geostationary Interferometric Infrared Sounder (GIIRS) onboard the Fengyun-4B satellite plays a critical role in numerical weather prediction and extreme weather monitoring. To meet the requirements of quantitative remote sensing and high-precision operational applications for radiometric calibration accuracy, this study, based on pre-launch calibration experiments, conducts a novel modeling analysis of the coupling between stray radiation at the input side and the system’s nonlinearity, and proposes a correction method for nonlinear coupling errors. This method explicitly models and physically traces the calibration residuals caused by stray radiation introduced via non-nominal optical paths under the effect of system nonlinearity, which are related to the radiance of the observed target. Experimental results show that, within the brightness temperature range of 200–320 K, the calibration bias is reduced from approximately 0.7 to 0.3–0.4 K, with good consistency and stability observed across channels and pixels.

21 June 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
YYYu Yu
Yu Yu
WFWei Fang
Wei Fang
DWDuo Wu
Duo Wu
SWSilong Wang
Silong Wang
ZLZhitao Luo
Zhitao Luo
Xin YeXin Ye
Xin Ye
The Moon-based Earth Radiation budget Detector (MERD) is an instrument designed to measure the Earth-reflected Solar Radiation (ERSR) and the Earth thermal radiation from the Moon as part of future mission of China's Chang'e project. The accuracy of its calibration technology directly determines the measurement precision. For traceability to International System of Units (SI) and improve the calibration accuracy in the ERSR wave band, a vacuum shortwave radiance calibration system is built, which consists of an in-situ traceable Electrical Substitution Transfer Radiometer (ESTR) and a Shortwave Calibration Light Source (SWCLS). Where, SWCLS is designed with a electrically variable slit and a 12-hole narrow-band filter wheel to achieve continuous broad-spectrum radiance output and discrete narrow-spectrum band tuning, respectively. Additionally, wide dynamic range output is from the introduction of elliptic land spherical mirrors for bilateral highly efficient focusing structure. This paper presents the mathematical process of shortwave calibration and focuses on the design and analysis of SWCLS based on high stability, radiance and uniformity. Results show that light source stability is 0.05922% / h, radiance uniformity is 99.49% at the calibration distance of 300 mm, the range of output radiant brightness in the spectral range 0.3-2.5 μm is 0.03-1272.20 W/m²/sr.