This article explores the possibility of diagnosing unwanted pressure drops in pneumatic systems. The proposed algorithm aims to distinguish the causes and location of their occurrence. The diagnostics clearly distinguish pressure drops caused by supply lines from those caused in the main or branch lines of an industrial pneumatic system. Pressure drops in pneumatic systems are one of the main causes of increased energy consumption. For the energy and resource optimization of pneumatic systems, it is essential to detect and locate the causes of pressure drops. This article proposes an approach for using the time diagrams of two measurable variables—flow rate and pressure—at the inlet of the end consumer (machine). Based on constant monitoring and a correlation relationship between the two time series, we determined indicators for detecting and locating unwanted pressure drops. In order to verify the proposed approach and the performed analysis, in general, we made observations of 16 real production machines and lines.
Industrial pneumatic systems are central to automated production but often exhibit low efficiency and high energy costs due to pressure drops, leaks, and related issues. Air leaks increase operational expenses and degrade actuator performance. This study introduces a reliable classification-based approach for subsystem-level localization of single leaks. Each operating cycle is mapped to one of four actionable states using a Dynamic Time Warping (DTW) algorithm applied to time-series data from a single inlet flowmeter, distributor switching signals, and actuator end-position sensors. The method distinguishes whether a leak occurs in the supply line, actuator circuit, or dynamically during the extension stroke. Unlike conventional metrics such as Euclidean, Canberra, and Pearson distances, DTW does not require equal-length signals and compensates for leak-induced temporal shifts, achieving complete class separation. Experimental validation included 200 cycles: 50 under normal conditions and 150 across three fault states (inlet leak, actuator leak, and dynamic leak), sampled at 10 Hz. DTW distances showed no overlap between class distributions. A Leave-One-Out 1-NN classifier achieved 100% accuracy across all classes. The approach is low-cost, automated, and suitable for real-time implementation with minimal sensors, supporting integration into machine learning frameworks and enhancing energy efficiency in pneumatic systems.
Short industrial compressed-air audits can contain thousands of samples while representing only a few dependent operating episodes. Autocorrelation therefore makes nominal sample count an unreliable basis for deciding whether a low-flow regime is sufficiently supported for an energy-efficiency or maintenance action. This paper proposes an audit-to-decision procedure separating three claims: that a low-flow regime exists, that it is measured reliably enough, and that its relative scale justifies action. hv-block selection and minimum-dwell reconstruction are combined with episode repeatability, effective intra-regime size, resampling uncertainty, metrological distinguishability, and relative non-productive consumption in a six-level action scale (D1–D6). The procedure was applied to 29 records from three operating plants. Five PLC-labeled records provided a limited external evaluation of the operational meaning of the identified low-flow state. Nominal BIC and hv-block selection differed in 20 of 24 audit records. Median deviation fell from 32.2–33.9% for nominal-selection baselines to 2.9% when the HMM used the hv-block-selected regime count. Outcomes were 3 × D1, 15 × D2, 7 × D3, and 4 × D4. D-codes were unchanged in 23/24 threshold-tested and 14/16 pressure-augmented records. In the five-record PLC-labeled evaluation, no action unsupported by the labels was triggered. The strongest time-series-only outcome is a mandatory diagnostic work order, not an automatic repair decision.
Compressed-air leaks create persistent parasitic demand, but machine-level condition monitoring is difficult because air consumption changes strongly with operating mode. LEADI (Leak Energy Anomaly Detection Index) was developed as an operating-mode-aware procedure that evaluates the deviation of directly measured flow rate from a local reference baseline derived from a stable post-repair condition with maintained pressure and low within-window variability. The method was developed on days 1–5 and evaluated on held-out days 6–7 from two one-week campaigns conducted before and after implementation of the prescribed corrective actions. With 60 min windows, LEADI flagged 19/19 evaluable pre-repair and 0/17 post-repair windows, with diagnostic coverage of 39.6% and 35.4%, respectively. A simple fifth-percentile flow comparator without operating-mode selection flagged 47/48 versus 1/48 windows. This shows that the low-flow region itself contains strong discriminatory information for separating the two periods. The role of the operating-mode layer is to restrict engineering interpretation to pre-specified eligible operating conditions. The flow-rate difference within the diagnostic operating condition was 122.0 L/min (95% CI 114.6–132.3). Over a common 168 h basis, measured volume decreased by 1370.8 m3 (28.90%), while a separate check normalized by pressurized time gave 28.12%. Because the specific energy consumption of the compressor station was not measured, the energy effect is reported only as a scenario for the same 168 h. The results support the applicability of LEADI as a selective decision-support layer for the investigated asset and the two observed conditions, without establishing universal leak detection or causal attribution of the observed change to individual defects.
Air duct contamination in HVAC systems degrades indoor air quality and reduces energy efficiency by increasing aerodynamic resistance, pressure drop, and electricity consumption. This study systematically analyzes contamination causes and their effects on indoor health, system performance, and energy use. It examines physical, biological, and chemical pollutants and their accumulation mechanisms. Emphasis is placed on inspection and diagnostic methods to guide effective monitoring strategies. Ten methods were evaluated using five criteria: reliability, applicability, speed, cost efficiency, and diagnostic value. Optical camera inspection with image processing and pressure drop measurement ranked highest, highlighting the importance of continuous monitoring for preventive maintenance and energy optimization.
The moisture sorption isotherms of corn extrudates fortified with ultrafiltration (UF) concentrate derived from rose wastewater (RWW) were examined. Two formulations containing 4 g (sample S4) and 11 g (sample S11) of retentate, respectively, per 100 g of semolina were prepared and subsequently extruded. Adsorption and desorption isotherms of both samples were determined at 10 °C, 25 °C and 40 °C using the static gravimetric method within a water activity range of 0.11–0.85. The experimental data of equilibrium moisture content (EMC) were fitted using modified GAB, modified Oswin, and modified Halsey equations. The monolayer moisture content of the samples was determined using the BET model. The results showed that the sorption isotherms exhibited a typical sigmoidal (Type II) shape and a pronounced hysteresis effect between adsorption and desorption. The hysteresis effect decreased with increasing temperature. Based on the combined evaluation of error analysis and residual distribution, the modified Oswin model provided the most balanced overall performance and was determined as suitable for the description of the sorption isotherms of the extrudates studied. The effect of UF-retentate level on EMC was not uniform and depended on temperature, water activity, and sorption direction. The monolayer moisture content of the extrudates varied from 4.08 to 8.39% d.b. The higher retentate level was generally associated with higher monolayer moisture values. Packaging and storage at the theoretically estimated range of water activities from 0.09 to 0.24 may be expected to maintain EMCs close to the monolayer.