Recent improvements in the low energy annihilation data and their influence on the determination of the hadronic contribution to the running of the QED fine structure constant at are discussed. Using CMD-2 and KLOE measurements in the region we obtain at .
1 February 1998 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Synchrotron radiation photons and off-energy electrons which contribute to backgrounds in the LEP experiments have been simulated. A multi-faceted background protection system has been designed and installed which permits the experiments to take data under very clean conditions. The backgrounds measured at LEP1 are in good agreement with calculations. Simulations and studies have led to a design of enhanced background protection for LEP2 where far more severe photon background is expected. Detector sensitivity to backgrounds and monitor systems are described.
We have updated our evaluation of the hadronic contribution to the running of the QED fine structure constant using the recent precise measurements of the e+e- annihilation at the center-of-mass (c.m.s.) energy region between 2.6 and 3.65~GeV performed by the BES collaboration. In the low-energy region, around the $\rho${} resonance, we include the recent measurements from the BABAR, CDM-2, KLOE, and SND collaborations. We obtain $\Delta${}$\alpha${}had(5)(s)=0.02750\ifmmode\pm\else\textpm\fi{}0.00033 at s=mZ2.
Dedicated high-beta optics are used to make forward proton scattering measurements possible at the LHC. Following a short general introduction and history of special high-beta optics and running conditions, we describe the two types of special high-beta runs planned for 2018. A run at top energy at for elastic and diffractive scattering, and a low energy run to measure the rho-parameter in the Coulomb interference region.
The intensities foreseen for injection into the LHC are over an order of magnitude above the expected damage levels. The TI 2 and TI 8 transfer lines between the SPS and LHC are each about 2.5 km long and comprise many magnet families. Despite power supply surveillance and interlocks, failure modes exist which could result in uncon- trolled beam loss and serious transfer line or LHC equip- ment damage. We describe the collimation system in the transfer lines that has been designed to provide passive pro- tection against damage. Results of simulations to develop a conceptual design are presented. The optical and physi- cal installation constraints are described, and the resulting element locations and expected system performance pre- sented, in terms of the phase space coverage, local element temperature rises and the characteristics of the beam trans- mitted into the LHC.
12 October 2001 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment