Alberto Redondas

Mr. Alberto Redondas

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2006 in Atmospheric Environment
Verified
Journal Article
Closed access
SOS.J. Oltmans
S.J. Oltmans
ALA.S. Lefohn
A.S. Lefohn
JHJ.M. Harris
J.M. Harris
IGI. Galbally
I. Galbally
HSH.E. Scheel
H.E. Scheel
EAEmilio Cuevas Agulló
Emilio Cuevas Agulló

1 March 2013 in Atmospheric Environment
Verified
Journal Article
Closed access
SOS.J. Oltmans
S.J. Oltmans
ALA.S. Lefohn
A.S. Lefohn
DSD. Shadwick
D. Shadwick
JHJ.M. Harris
J.M. Harris
HSH.E. Scheel
H.E. Scheel
TKT. Kawasato
T. Kawasato

2 October 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KGKaterina Garane
Katerina Garane
MKMaria-Elissavet Koukouli
Maria-Elissavet Koukouli
TVTijl Verhoelst
Tijl Verhoelst
CLChristophe Lerot
Christophe Lerot
KHKlaus-Peter Heue
Klaus-Peter Heue
WZWalter Zimmer
Walter Zimmer
In October 2017, the Sentinel-5 Precursor (S5P) mission was launched, carrying the TROPOspheric Monitoring Instrument (TROPOMI), which provides a daily global coverage at a spatial resolution as high as 7 km × 3.5 km and is expected to extend the European atmospheric composition record initiated with GOME/ERS-2 in 1995, enhancing our scientific knowledge of atmospheric processes with its unprecedented spatial resolution. Due to the ongoing need to understand and monitor the recovery of the ozone layer, as well as the evolution of tropospheric pollution, total ozone remains one of the leading species of interest during this mission. In this work, the TROPOMI near real time (NRTI) and offline (OFFL) total ozone column (TOC) products are presented and compared to daily ground-based quality-assured Brewer and Dobson TOC measurements deposited in the World Ozone and Ultraviolet Radiation Data Centre (WOUDC). Additional comparisons to individual Brewer measurements from the Canadian Brewer Network and the European Brewer Network (Eubrewnet) are performed. Furthermore, twilight zenith-sky measurements obtained with ZSL-DOAS (Zenith Scattered Light Differential Optical Absorption Spectroscopy) instruments, which form part of the SAOZ network (Système d'Analyse par Observation Zénitale), are used for the validation. The quality of the TROPOMI TOC data is evaluated in terms of the influence of location, solar zenith angle, viewing angle, season, effective temperature, surface albedo and clouds. For this purpose, globally distributed ground-based measurements have been utilized as the background truth. The overall statistical analysis of the global comparison shows that the mean bias and the mean standard deviation of the percentage difference between TROPOMI and ground-based TOC is within 0 –1.5 % and 2.5 %–4.5 %, respectively. The mean bias that results from the comparisons is well within the S5P product requirements, while the mean standard deviation is very close to those limits, especially considering that the statistics shown here originate both from the satellite and the ground-based measurements. Additionally, the TROPOMI OFFL and NRTI products are evaluated against already known spaceborne sensors, namely, the Ozone Mapping Profiler Suite, on board the Suomi National Polar-orbiting Partnership (OMPS/Suomi-NPP), NASA v2 TOCs, and the Global Ozone Monitoring Experiment 2 (GOME-2), on board the Metop-A (GOME-2/Metop-A) and Metop-B (GOME-2/Metop-B) satellites. This analysis shows a very good agreement for both TROPOMI products with well-established instruments, with the absolute differences in mean bias and mean standard deviation being below +0.7 % and 1 %, respectively. These results assure the scientific community of the good quality of the TROPOMI TOC products during its first year of operation and enhance the already prevalent expectation that TROPOMI/S5P will play a very significant role in the continuity of ozone monitoring from space.

27 July 2008 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
VFVitali Fioletov
Vitali Fioletov
GLG. Labow
G. Labow
RER. Evans
R. Evans
EHE. W. Hare
E. W. Hare
UKU. Köhler
U. Köhler
MWM. Weber
M. Weber
Dobson and Brewer spectrophotometer and filter ozonometer data available from the World Ozone and Ultraviolet Data Centre (WOUDC) were compared with satellite total ozone measurements from TOMS (onboard Nimbus 7, Meteor 3, and Earth Probe satellites), OMI (AURA satellite) and GOME (ERS‐2 satellite) instruments. Five characteristics of the difference with satellite data were calculated for each site and instrument type: the mean difference, the standard deviation of daily differences, the standard deviation of monthly differences, the amplitude of the seasonal component of the difference, and the range of annual values. All these characteristics were calculated for five 5‐year‐long bins and for each site separately for direct sun (DS) and zenith sky (ZS) ozone measurements. The main percentiles were estimated for the five characteristics of the difference and then used to establish criteria for “suspect” or “outlier” sites for each characteristic. About 61% of Dobson, 46% of Brewer, and 28% of filter stations located between 60°S and 60°N have no “suspect” or “outlier” characteristics. In nearly 90% of all cases, Dobson and Brewer sites demonstrated 5‐year mean differences with satellites to be within ±3% (for DS observations). The seasonal median difference between all Brewer DS measurements at 25°–60°N and GOME and OMI overpasses remained within ±0.5% over a period of more than 10 years. The satellite instrument performance was also analyzed to determine typical measurement uncertainties. It is demonstrated that systematic differences between the analyzed satellite instruments are typically within ±2% and very rarely are they outside the ±3% envelope. As the satellite instrument measurements appear to be better than ±3%, ground‐based instruments with precision values worse than ±3% are not particularly useful for the analyses of long‐term changes and comparison with numerical simulations.

19 December 2007 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
MSM. R. Schoeberl
M. R. Schoeberl
JZJ. R. Ziemke
J. R. Ziemke
BBB. Bojkov
B. Bojkov
NLN. Livesey
N. Livesey
BDB. Duncan
B. Duncan
EJE. Joseph
E. Joseph
We estimate the tropospheric column ozone using a forward trajectory model to increase the horizontal resolution of the Aura Microwave Limb Sounder (MLS) derived stratospheric column ozone. Subtracting the MLS stratospheric column from Ozone Monitoring Instrument total column measurements gives the trajectory enhanced tropospheric ozone residual (TTOR). Because of different tropopause definitions, we validate the basic residual technique by computing the 200‐hPa‐to‐surface column and comparing it to the same product from ozonesondes and Tropospheric Emission Spectrometer measurements. Comparisons show good agreement in the tropics and reasonable agreement at middle latitudes, but there is a persistent low bias in the TTOR that may be due to a slight high bias in MLS stratospheric column. With the improved stratospheric column resolution, we note a strong correlation of extratropical tropospheric ozone column anomalies with probable troposphere‐stratosphere exchange events or folds. The folds can be identified by their colocation with strong horizontal tropopause gradients. TTOR anomalies due to folds may be mistaken for pollution events since folds often occur in the Atlantic and Pacific pollution corridors. We also compare the 200‐hPa‐to‐surface column with Global Modeling Initiative chemical model estimates of the same quantity. While the tropical comparisons are good, we note that chemical model variations in 200‐hPa‐to‐surface column at middle latitudes are much smaller than seen in the TTOR.

12 February 2014 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
ARAlberto Redondas
Alberto Redondas
RER. Evans
R. Evans
RSR. Stuebi
R. Stuebi
UKU. Köhler
U. Köhler
MWM. Weber
M. Weber
The primary ground-based instruments used to report total column ozone (TOC) are Brewer and Dobson spectrophotometers in separate networks. These instruments make measurements of the UV irradiances, and through a well-defined process, a TOC value is produced. Inherent to the algorithm is the use of a laboratory-determined cross-section data set. We used five ozone cross-section data sets: three data sets that are based on measurements of Bass and Paur; one derived from Daumont, Brion and Malicet (DBM); and a new set determined by Institute of Experimental Physics (IUP), University of Bremen. The three Bass and Paur (1985) sets are as follows: quadratic temperature coefficients from the IGACO (a glossary is provided in Appendix A) web page (IGQ4), the Brewer network operational calibration set (BOp), and the set used by Bernhard et al. (2005) in the reanalysis of the Dobson absorption coefficient values (B05). The ozone absorption coefficients for Brewer and Dobson instruments are then calculated using the normal Brewer operative method, which is essentially the same as that used for Dobson instruments. Considering the standard TOC algorithm for the Brewer instruments and comparing to the Brewer standard operational calibration data set, using the slit functions for the individual instruments, we find the IUP data set changes the calculated TOC by −0.5%, the DBM data set changes the calculated TOC by −3.2%, and the IGQ4 data set at −45 °C changes the calculated TOC by +1.3%. Considering the standard algorithm for the Dobson instruments, and comparing to results using the official 1992 ozone absorption coefficients values and the single set of slit functions defined for all Dobson instruments, the calculated TOC changes by +1%, with little variation depending on which data set is used. We applied the changes to the European Dobson and Brewer reference instruments during the Izaña 2012 Absolute Calibration Campaign. With the application of a common Langley calibration and the IUP cross section, the differences between Brewer and Dobson data sets vanish, whereas using those of Bass and Paur and DBM produces differences of 1.5 and 2%, respectively. A study of the temperature dependence of these cross-section data sets is presented using the Arosa, Switzerland, total ozone record of 2003–2006, obtained from two Brewer-type instruments and one Dobson-type instrument, combined with the stratospheric ozone and temperature profiles from the Payerne soundings in the same period. The seasonal dependence of the differences between the results from the various instruments is greatly reduced with the application of temperature-dependent absorption coefficients, with the greatest reduction obtained using the IUP data set.