Purpose: This study investigated the effect of the osteotomy diameter for implant placement torque and its effect on the osseointegration. Materials and Methods: Eight male beagle dogs received 48 implants (3.75 mm × 10 mm) in their right and left radius, 3 implants per side and allowed to heal for 3 weeks. Three experimental groups were evaluated. Group 1: implant with an undersized osteotomy of 3.0 mm; group 2: osteotomy of 3.25 mm, and group 3: osteotomy of 3.5 mm. The insertion torque was recorded for all implants. Histological sectioning and histometric analysis were performed evaluating bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Results: Implants of group 1 presented statistically higher insertion torque than those of groups 2 and 3 (P < 0.01). No differences in BIC or BAFO were observed between the groups. From a morphologic standpoint, substantial deviations in healing mode were observed between groups. Conclusion: Based on the present methodology, the experimental alterations of surgical technic can be clinically used with no detrimental effect over the osseointegration process.
Traumatic injuries treatment of the fronto-naso-orbito-ethmoidal region has been one of the most challenging treatments within maxillofacial surgery, particularly of extensive orbital defects, very common in this type of pathologic condition. A 48-year-old man involved in a car collision presented an extensive bilateral fracture of the orbit medial wall, nasal bones, the nasal septum, and the frontal anterior table. The clinical and tomographic findings concluded the diagnosis of a maxilla and fronto-naso-orbito-ethmoidal fracture. Among the variety of biomaterials, the titanium mesh was elected because of the extension and magnitude of the bone defect, obtaining this way esthetic and functional results with better prognosis.
23 January 2025 in Clinical Oral Implants Research
Objective: To evaluate the Microimplant-assisted Rapid Palatal Expansion (MARPE), considered an alternative to surgical interventions for disjunction of the midpalatal suture in adolescent patients and young adults with maxillary transverse deficiency. The stage of ossification of the midpalatal suture, bone quality and adequate activation protocols are factors that can influence the quantity and quality of the orthopedic separation. Methodology: This paper demonstrates the application of MARPE in an unfavorable case report, of an adult patient with total crossbite, in an advanced stage of fusion of the palatine and maxillary processes, with poverty in the posterior bone volume, in comparison with the same therapy in an adolescent at an earlier stage of sutural maturation. In both cases, after tomographic examinations and oral scanning, the installations and recommended activation protocol were performed. These were not sufficient in the case of the adult patient, and generated side effects that, to be overcome, required changes in activations and additional maneuvers. Results: The application of MARPE may require clinical versatility to adopt differentiated protocols in relation to chronological age, bone thickness and sutural ossification stage. Conclusion: In the end, new computer tomography scans and a clinical examination showed satisfactory results in both patients. In the unfavorable case, the opening of the midpalatal suture occurred at more modest levels, but it was sufficient to correct the posterior crossbite.
3 August 2021 in Research, Society and Development
A hiperpneumatização do seio maxilar é um fator complicador para a instalação de implantes na região posterior de maxila. O levantamento do assoalho do seio maxilar é uma alternativa para possibilitar a instalação de implantes nestes casos. Entretanto, complicações transcirúrgicas podem ocorrer, sendo a perfuração da membrana de Schneider a mais comum. Diversas manobras são descritas na literatura no manejo das perfurações da membrana sinusal, possibilitando o reparo e a execução do procedimento de enxertia no mesmo momento cirúrgico. Dentre as formas de reparo, a utilização de membranas de Fibrina Rica em Plaquetas e Leucócitos (L-PRF) tem sido apresentada como uma opção de tratamento com resultados interessantes e promissores para se alcançar o reparo. Este trabalho descreve um caso clínico onde a perfuração da membrana de Schneider foi reparada com membranas de L-PRF e o procedimento realizado sem intercorrências pós-operatórias, possibilitando a posterior instalação de implantes e o sucesso da reabilitação.