Chen Jing

Dr. Chen Jing


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2023 in Foods
Verified
Journal Article
Open access
PDF file
WLwang liyuan
wang liyuan
ZHZhengyan Hu
Zhengyan Hu
CJChen Jing
Chen Jing
TWTianjiao Wang
Tianjiao Wang
PWPinggu Wu
Pinggu Wu
YYYing Ying
Ying Ying
(1) Background: Preservatives may pose a potential threat to human health. To ensure food safety, this study has devised a method that concurrently detects a dozen preservatives (acetic acid, propionic acid, dehydroacetic acid, benzoic acid, sorbic acid, dimethyl fumarate, methyl parahydroxybenzoate, ethyl parahydroxybenzoate, propyl parahydroxybenzoate, isopropyl parahydroxybenzoate, butyl parahydroxybenzoate, and isobutyl parahydroxybenzoate) in pastry, utilizing gas chromatography–mass spectrometry. (2) Methods: The pastry samples were acidified with hydrochloric acid, extracted with acetonitrile via vortexing, purified by hexane and saturated with sodium chloride solution to remove lipids and impurities, and then concentrated via nitrogen blowing. The method was then quantitatively analyzed using GC-MS with the internal standard method after methanol re-dissolution. (3) Results: The results showed that the content of the 12 preservatives had good linearity within the range of 1.0–50 μg/mL, with correlation coefficients all greater than 0.99. The method detection limit was 0.04–2.00 mg/kg and the quantification limit was 0.12–6.67 mg/kg. The average recovery rates of the samples at three different spiked concentrations of low, medium, and high were 70.18–109.22%, and the relative standard deviations were 1.82–9.79% (n = 6). (4) Conclusions: This method requires a small amount of sample, has high sensitivity, and is simple and fast to operate, making it suitable for the simultaneous determination of 12 preservatives in pastry. This approach contributes to the effective surveillance and regulation of preservative usage in pastries, thereby safeguarding public well-being.

21 October 2025 in Frontiers in Nutrition
Verified
Journal Article
Open access
PDF file
YYYing Ying
Ying Ying
ZHZhengyan Hu
Zhengyan Hu
PWPinggu Wu
Pinggu Wu
XLXianfa Luo
Xianfa Luo
WLwang liyuan
wang liyuan
CJChen Jing
Chen Jing
Background: Pre-prepared dishes contain fats/oils, high protein, and complex seasonings, making sterol detection difficult due to multiple components and matrix interference. Given the market’s analytical challenges, detecting sterols—key functional components affecting nutritional value—is practically vital. This study aims to develop a sensitive, selective GC–MS method for simultaneous qualitative and quantitative multi-component sterol analysis in pre-prepared dishes and to examine their compositional traits.Methods: After saponification treatment, the sample undergoes ultrapure water-assisted dispersion and n-hexane extraction. The extract is dried and subjected to derivatization reaction. The derivative is redissolved and analyzed by gas chromatography–mass spectrometry (GC–MS) for qualitative identification, with quantification performed using the internal standard method. This method optimizes sample pretreatment and chromatographic separation conditions, enhancing detection efficiency and separation effectiveness.Results: The six target sterol compounds exhibited good linearity within the concentration range of 1.0–100.0 μg/mL (correlation coefficients ≥0.99). The limits of detection (LODs) and limits of quantification (LOQs) were 0.05–5.0 mg/100 g and 0.165–16.5 mg/100 g, respectively. At low, medium, and high spiked concentrations, the average recoveries ranged from 87.0 to 106%, with relative standard deviations (RSDs, n = 6) of 0.99–9.00%. Application of this method to analyze actual pre-prepared dish samples revealed significant variations in cholesterol content among different dish categories, with meat ingredients playing a dominant role. The sterol composition exhibited marked diversity: ergosterol was not detected in pre-prepared dishes, while β-sitosterol, campesterol, and stigmasterol constituted the major components. Notable differences in sterol content and composition were observed across different categories of pre-prepared dishes, further confirming the impact of various meat raw materials and processing technologies on sterol levels.Conclusion: The GC–MS analytical method established in this study has been validated to demonstrate excellent reliability and applicability, providing an efficient analytical tool for precise detection of multi-component sterols in pre-prepared dishes. This method supports quality control and nutritional value assessment in the pre-prepared dish industry, facilitating product labeling standardization and informed consumer choices.