Low-voltage distribution area is the “last kilometer” connecting the distribution network and users, and the traditional distribution system is difficult to digitally manage in the low-voltage area, resulting in untimely and imprecise handling of voltage overruns, short-circuit outages, and other abnormal problems. With the deployment of smart meters, new sensors, smart gateways, and other devices in distribution areas, digital intelligent monitoring and management based on digital twins in LV distribution areas has gradually become the focus of distribution network research. In view of the profound changes that are taking place in the low-voltage distribution area, this paper first summarizes the characteristics and shortcomings of the existing digital twin research in the low-voltage distribution area, then puts forward the ‘6C’ development goals for the digital transformation of the low-voltage distribution area, introduces the practice work of Guangxi Power Grid Corporation around the ‘6C’ development goals in the low-voltage distribution area. Finally, the future research work of the ‘6C’ development goals for the digital transformation of the low-voltage distribution area is promising.
This paper analyzes the transient voltage stability of the dual-source DC power system. The system’s equivalent model is first established. Subsequently, the effect mechanisms of line parameters and voltage-source rectifiers’ current control inner loops on the system’s transient voltage instability are investigated. It indicates that these factors reduce the power supply capacity of the source, increasing the risk of transient instability in the system. Then, considering the influence of fault depths, the influence of different large disturbances on the transient voltage stability is investigated. Furthermore, the critical cutting voltage and critical cutting time for DC power systems are determined and then validated on the MATLAB R2023b/Simulink platform. Finally, based on the mixed potential function theory, the impact of system parameter variations on stability boundaries is analyzed quantitatively. Simulation verification is conducted on the MATLAB R2023b/Simulink platform, and experimental verification is conducted on the RT-LAB Hardware-in-the-Loop platform. The results of the quantitative analysis and experiments corroborate the conclusions drawn from the mechanistic analysis, underscoring the critical role of line parameters and converter control parameters in the system’s transient voltage stability.