Tekin Izgi

Dr. Tekin Izgi


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Selcuk AtalaySelcuk Atalay
Selcuk Atalay
TITekin Izgi
Tekin Izgi
Veli Serkan KolatVeli Serkan Kolat
Veli Serkan Kolat
SESema Erdemoğlu
Sema Erdemoğlu
HYHatice Çağlar Yılmaz
Hatice Çağlar Yılmaz
In this study, TiO2 nanotubes (TiO2-NTs) are coated with a drop-casting method on Fe40Ni38Mo4B18 amorphous ferromagnetic ribbons and the humidity response of the prepared magnetoelastic sensors (MES) is investigated. The synthesis of TiO2-NTs is performed using a hydrothermal process. Sample characterization is carried out using X-ray diffraction and scanning electron microscopy. The results show that the sensors can measure moisture values in the range of 5% to 95% with very high precision and very low hysteresis. The humidity variation between 5% and 95% shows a change in the sensor resonance frequency of ~3180 Hz, which is a significant change compared to many magnetoelastic humidity sensors developed so far.

11 February 2016 in Journal of Superconductivity and Novel Magnetism
Verified
Journal Article
Closed access
PDF file
SAS. Atalay
S. Atalay
VKV. S. Kolat
V. S. Kolat
NBN. Bayri
N. Bayri
TITekin Izgi
Tekin Izgi

12 August 2020 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
MPM. Pektas
M. Pektas
TITekin Izgi
Tekin Izgi
HGH. Gencer
H. Gencer
SAS. Atalay
S. Atalay
VKV. S. Kolat
V. S. Kolat
NBN. Bayri
N. Bayri

6 May 2021 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
MPM. Pektas
M. Pektas
VKV. S. Kolat
V. S. Kolat
NBN. Bayri
N. Bayri
TITekin Izgi
Tekin Izgi
SAS. Atalay
S. Atalay

12 February 2021 in Research Square
Verified
Preprint
Open access
PDF file
TITekin Izgi
Tekin Izgi
MPM. Pektas
M. Pektas
VKV.S. Kolat
V.S. Kolat
NBN. Bayri
N. Bayri
SAS. Atalay
S. Atalay
A magnetic field sensor was developed using asymmetric giant magnetoimpedance (AGMI) effect. Amorphous ferromagnetic (Fe0.06Co0.94) 72.5Si12.5B15 wires were used in this study. The 2 cm long wire showed about 88 % and the 7 cm long wire showed about 197 % giant magnetoimpedance effect. When two micro magnets were placed 1 cm away from the ends of the wire, a distortion in two peak shapes of the GMI curve was observed and asymmetry was created by micro magnets and 7 cm long wire showed about 148 % AGMI effect. A simple and a new approach was designed to develop a magnetic field sensor, in the design circuit two signal generators were used to arrange linearity and dc offset in the output signal. The circuit output showed good linearity and zero hysteresis at ±250 A/m and ± 50 A/m magnetic field regions for 2cm wires long and 7 cm wires long, respectively.

1 July 2019 in Acta Physica Polonica A
Verified
Journal Article
Closed access
HGH. Gencer
H. Gencer
UOU. Ozkan
U. Ozkan
NBN. Bayri
N. Bayri
TITekin Izgi
Tekin Izgi
VKV. Kolat
V. Kolat