Using a sample of events accumulated with the BES II detector, evidence for production in decays is obtained for the first time; the branching ratio is determined to be . The significance of the signal is about 4.6.
Non- decay is searched for using a data sample of taken at the center-of-mass energy of 3.773 GeV by the BESII detector at the BEPC. No signal is observed, and the upper limit of the cross section is measured to be at 90% C. L. Considering the interference between the continuum amplitude and the resonance amplitude, the branching fraction of decays to is determined to be at 90% C. L. This is in agreement with the prediction of the - and -wave mixing scheme of the charmonium states for solving the “ puzzle” between and decays.
Non-rigid multi-modal image registration plays an important role in medical image processing and analysis. Existing image registration methods based on similarity metrics such as mutual information (MI) and sum of squared differences (SSD) cannot achieve either high registration accuracy or high registration efficiency. To address this problem, we propose a novel two phase non-rigid multi-modal image registration method by combining Weber local descriptor (WLD) based similarity metrics with the normalized mutual information (NMI) using the diffeomorphic free-form deformation (FFD) model. The first phase aims at recovering the large deformation component using the WLD based non-local SSD (wldNSSD) or weighted structural similarity (wldWSSIM). Based on the output of the former phase, the second phase is focused on getting accurate transformation parameters related to the small deformation using the NMI. Extensive experiments on T1, T2 and PD weighted MR images demonstrate that the proposed wldNSSD-NMI or wldWSSIM-NMI method outperforms the registration methods based on the NMI, the conditional mutual information (CMI), the SSD on entropy images (ESSD) and the ESSD-NMI in terms of registration accuracy and computation efficiency.
The non‐local means (NLM) method explores self‐similarities in images for noise removal. The traditional NLM (TNLM) method computes pixel similarity using the globally fixed decay parameter. However, a fixed decay parameter for the whole image makes it difficult to ensure that the TNLM method can restore both edge pixels and non‐edge pixels effectively. To address this problem, the SUSAN controlled NLM (SNLM) method is proposed to adaptively tune the decay parameter for each image pixel based on the SUSAN edge response. Extensive simulations demonstrate that the SNLM method outperforms several state‐of‐the‐art NLM methods in terms of noise reduction and detail preservation.