Yijhe Huang

Mr. Yijhe Huang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Yijhe HuangYijhe Huang
Yijhe Huang
JCJyh-Wen Chai
Jyh-Wen Chai
WCWen-Hsien Chen
Wen-Hsien Chen
Hung-Chieh ChenHung-Chieh Chen
Hung-Chieh Chen
Da-Chuan ChengDa-Chuan Cheng
Da-Chuan Cheng
Background/Objectives: Spontaneous intracranial hypotension (SIH), caused by spinal cerebrospinal fluid (CSF) leakage, commonly presents with orthostatic headache and CSF hypovolemia. While CSF dynamics in the cerebral aqueduct are well studied, alterations in spinal CSF flow remain less defined. We aimed to quantitatively assess spinal CSF flow at C2 using phase-contrast (PC) MRI enhanced by artificial intelligence (AI) and to evaluate its utility for diagnosing SIH and predicting responses to epidural blood patch (EBP). Methods: We enrolled 31 patients with MRI-confirmed SIH and 26 age- and sex-matched healthy volunteers (HVs). All participants underwent ECG-gated cine PC-MRI at the C2 level and whole-spine MR myelography. AI-based segmentation using YOLOv4 and a pulsatility-based algorithm was used to extract quantitative CSF flow metrics. Between-group comparisons were analyzed using Mann–Whitney U tests, and receiver operating characteristic (ROC) analysis was used to evaluate diagnostic and predictive performance. Results: Compared to HVs, SIH patients showed significantly reduced CSF flow parameters across all metrics, including upward/downward mean flow, peak flow, total flow per cycle, and absolute stroke volume (all p < 0.001). ROC analysis revealed excellent diagnostic accuracy for multiple parameters, particularly downward peak flow (AUC = 0.844) and summation of peak flow (AUC = 0.841). Importantly, baseline CSF flow metrics significantly distinguished patients who required one versus multiple epidural blood patches (EBPs) (all p < 0.001). ROC analysis demonstrated that several parameters achieved near-perfect to perfect accuracy in predicting EBP success, with AUCs up to 1.0 and 100% sensitivity/specificity. Conclusions: AI-enhanced PC-MRI enables the robust, quantitative evaluation of spinal CSF dynamics in SIH. These flow metrics not only differentiate SIH patients from healthy individuals but also predict response to EBP treatment with high accuracy. Quantitative CSF flow analysis may support both diagnosis and personalized treatment planning in SIH.

17 March 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Yijhe HuangYijhe Huang
Yijhe Huang
Hung-Chieh ChenHung-Chieh Chen
Hung-Chieh Chen
Da-Chuan ChengDa-Chuan Cheng
Da-Chuan Cheng
Background/Objectives: Spontaneous intracranial hypotension (SIH) is caused by spinal cerebrospinal fluid (CSF) leakage and is typically diagnosed by clinical presentation and characteristic MRI signs; however, objective tools for monitoring physiological alterations and treatment response remain limited. Cine phase-contrast MRI (PC-MRI) enables noninvasive quantification of aqueductal CSF dynamics, yet reliable analysis is challenging since the cerebral aqueduct is extremely small and susceptible to low contrast, partial volume effects, and ROI-dependent measurement variability—particularly in SIH where CSF pulsatility is often reduced. Methods: We propose an end-to-end automated framework that integrates (1) a cascade localization–segmentation strategy (Tiny YOLOv4 detection followed by MultiResUNet segmentation on a cropped ROI form YOLOv4 result; (2) physiology-informed pulsatility-based segmentation (PUBS) to refine anatomical masks into functional flow ROIs, and (3) one-dimensional convolutional neural networks (1D-CNNs) to learn waveform morphology biomarkers from 32-phase cardiac-cycle velocity waveforms. The study includes 39 participants (11 controls; 28 pre-treatment SIH; 20 post-treatment recovery). Results: The cascade model significantly improves segmentation robustness compared with a full-image baseline, achieving higher Dice scores and markedly lower boundary errors across cohorts (e.g., pre-treatment SIH HD95: 1.66 ± 0.74 px vs. 15.37 ± 44.98 px). PUBS refinement reduced quantification deviation from expert manual references in SIH (mean relative error: 7.4% to 5.6%) and improved diagnostic performance for multiple hemodynamic parameters (e.g., downward mean flow AUC: 0.747 to 0.792). Importantly, waveform morphology learning substantially outperformed conventional scalar metrics: peak systolic CSF velocity (PSV) showed limited discrimination (AUC 0.69), whereas the full morphology AI model achieved AUC 0.96. A single trait-like morphology feature reached AUC 0.98 with 100% specificity, while a state-dependent feature normalized after recovery, indicating complementary utility for diagnosis and longitudinal monitoring. Conclusions: This fully automated, reproducible, and physiologically informed pipeline demonstrates that SIH-related information is not only reflected in flow magnitude but also encoded in subtle aqueductal CSF waveform shape patterns, supporting morphology-based biomarkers as a promising tool for SIH assessment and follow-up.

22 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
Yijhe HuangYijhe Huang
Yijhe Huang
WCWen-Hsien Chen
Wen-Hsien Chen
Hung-Chieh ChenHung-Chieh Chen
Hung-Chieh Chen
Da-Chuan ChengDa-Chuan Cheng
Da-Chuan Cheng
Background/Objectives: Spontaneous intracranial hypotension (SIH) is caused by spinal cerebrospinal fluid (CSF) leakage and is typically diagnosed by clinical presentation and characteristic MRI signs; however, objective tools for monitoring physiological changes and treatment response remain limited. Cine phase-contrast MRI (PC-MRI) enables noninvasive quantification of aqueductal CSF dynamics, yet reliable analysis is challenging since the cerebral aqueduct is extremely small and susceptible to low contrast, partial volume effects, and ROI-dependent measurement variability—particularly in SIH where CSF pulsatility is often reduced. Methods: We propose an end-to-end automated framework that integrates (1) a cascade localization–segmentation strategy, consisting of Tiny YOLOv4 detection followed by MultiResUNet segmentation on a YOLOv4-derived cropped ROI; (2) physiology-informed pulsatility-based segmentation (PUBS) to refine anatomical masks into functional flow ROIs; and (3) one-dimensional convolutional neural networks (1D-CNNs) to extract exploratory waveform morphology features from 32-phase cardiac-cycle velocity waveforms. The study includes 39 participants, yielding 59 cine PC-MRI examinations: 11 controls, 28 Pre-treatment SIH scans and 20 Post-treatment Recovery scans. Results: The cascade model significantly improves segmentation robustness compared with a full-image baseline, achieving higher Dice scores and markedly lower boundary errors across cohorts (e.g., Pre-treatment SIH HD95: 1.66 ± 0.74 px vs. 15.37 ± 44.98 px). PUBS refinement reduces quantification deviation from expert manual references in SIH (mean relative error: 7.4% to 5.6%) and improves diagnostic performance for multiple hemodynamic parameters (e.g., downward mean flow AUC: 0.747 to 0.792). For waveform morphology analysis, the end-to-end 1D-CNN classifier was evaluated using repeated-seed participant-level grouped LOOCV. The repeated-seed ensemble prediction showed modest out-of-sample discrimination between Normal controls and Pre-treatment SIH scans, with an AUC of 0.646, a bootstrap 95% confidence interval of 0.455–0.826, and a permutation-test p-value of 0.072. Separately, exploratory analysis of the final baseline-trained 1D-CNN latent space showed marked, apparent Normal-versus-SIH separability and an intermediate recovery distribution in PCA space, suggesting that aqueductal waveform morphology may encode SIH-related physiological information. Conclusions: These findings suggest that SIH-related information may be reflected not only in flow magnitude but also in aqueductal CSF waveform morphology. However, the modest and statistically non-significant out-of-sample performance of the end-to-end 1D-CNN classifier indicates that morphology-based AI features should currently be regarded as exploratory biomarker candidates rather than validated stand-alone diagnostic tools. Larger independent cohorts are required to confirm their reproducibility, physiological meaning, and clinical utility.