Cell refractive index is an important biophysical parameter, which provides new biological and biomedical insight for disease diagnosis and cell biology.
This paper reports an optofluidic lens with low spherical and low field curvature aberrations through the desired refractive index profile by precisely controlling the mixing between ethylene glycol and deionized water in an optofluidic chip. The experimental results demonstrate that the spherical aberration is reduced to 19.5 μm and the full width at half maximum of the focal point is 7.8 μm with a wide divergence angle of 35 degrees. In addition, the optofluidic lens can focus light at different off-axis positions on the focal plane with Δx′ < 6.8 μm and at opposite transverse positions with |Δy − Δy′| < 5.7 μm. This is the first demonstration of a special optofluidic lens that significantly reduces both the spherical and field curvature aberrations, which enhances the focusing power and facilitates multiple light source illumination using a single lens. It is anticipated to have high potential for applications such as on-chip light manipulation, sample illumination and multiplexed detection.
It is well known that the presence of sensor position errors may lead to failure of farfield/nearfield wideband beamformers for microphone arrays. Therefore, many efforts have been made to design wideband beamformers for microphone arrays robust against sensor position errors in recent years. This paper presents the findings obtained on the study and analysis of the effects of sensor position errors to the performance of farfield/nearfield wideband beamformers for microphone arrays. Several useful properties have been derived through the conduct of a comprehensive statistical analysis, including the bias and variance analysis of array response, to provide in-depth insights into the robustness characteristics of farfield and nearfield wideband beamformers in the presence of sensor position errors. The analysis does not assume any specific array geometry and is thus applicable to arrays with arbitrary geometries. Numerical examples obtained via Monte Carlo simulations are presented to verify the proposed theoretical analysis. This paper is helpful to better understand the effects of sensor position errors on wideband beamformers and useful in microphone array design.
28 October 2009 in Journal of Signal Processing Systems
Smart wearable sensors are essential for continuous health-monitoring applications and detection accuracy of symptoms and energy efficiency of processing algorithms are key challenges for such devices. While several machine-learning-based algorithms for the detection of abnormal breath sounds are reported in literature, they are either too computationally expensive to implement into a wearable device or inaccurate in multi-class detection. In this paper, a kernel-like minimum distance classifier (K-MDC) for acoustic signal processing in wearable devices was proposed. The proposed algorithm was tested with data acquired from open-source databases, participants, and hospitals. It was observed that the proposed K-MDC classifier achieves accurate detection in up to 91.23% of cases, and it reaches various detection accuracies with a fewer number of features compared with other classifiers. The proposed algorithm’s low computational complexity and classification effectiveness translate to great potential for implementation in health-monitoring wearable devices.
19 July 2018 in Biomedical Signal Processing and Control