Wee Ser

Dr. Wee Ser

SPACE (MedTech) Pte. Ltd., Singapore 415978, Singapore

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PLP. Y. Liu
P. Y. Liu
LCL. K. Chin
L. K. Chin
Wee SerWee Ser
Wee Ser
HCH. F. Chen
H. F. Chen
CHC.-M. Hsieh
C.-M. Hsieh
Yamin Leprince-WangYamin Leprince-Wang
Yamin Leprince-Wang
Cell refractive index is an important biophysical parameter, which provides new biological and biomedical insight for disease diagnosis and cell biology.

21 March 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Haitao ZhaoHaitao Zhao
Haitao Zhao
YYY. Yang
Y. Yang
LCL. K. Chin
L. K. Chin
HCH. F. Chen
H. F. Chen
WZW. M. Zhu
W. M. Zhu
Ai Qun LiuAi Qun Liu
Ai Qun Liu
This paper reports an optofluidic lens with low spherical and low field curvature aberrations through the desired refractive index profile by precisely controlling the mixing between ethylene glycol and deionized water in an optofluidic chip. The experimental results demonstrate that the spherical aberration is reduced to 19.5 μm and the full width at half maximum of the focal point is 7.8 μm with a wide divergence angle of 35 degrees. In addition, the optofluidic lens can focus light at different off-axis positions on the focal plane with Δx′ < 6.8 μm and at opposite transverse positions with |Δy − Δy′| < 5.7 μm. This is the first demonstration of a special optofluidic lens that significantly reduces both the spherical and field curvature aberrations, which enhances the focusing power and facilitates multiple light source illumination using a single lens. It is anticipated to have high potential for applications such as on-chip light manipulation, sample illumination and multiplexed detection.

11 May 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HCHuawei Chen
Huawei Chen
YBYu Bao
Yu Bao
Wee SerWee Ser
Wee Ser
It is well known that the presence of sensor position errors may lead to failure of farfield/nearfield wideband beamformers for microphone arrays. Therefore, many efforts have been made to design wideband beamformers for microphone arrays robust against sensor position errors in recent years. This paper presents the findings obtained on the study and analysis of the effects of sensor position errors to the performance of farfield/nearfield wideband beamformers for microphone arrays. Several useful properties have been derived through the conduct of a comprehensive statistical analysis, including the bias and variance analysis of array response, to provide in-depth insights into the robustness characteristics of farfield and nearfield wideband beamformers in the presence of sensor position errors. The analysis does not assume any specific array geometry and is thus applicable to arrays with arbitrary geometries. Numerical examples obtained via Monte Carlo simulations are presented to verify the proposed theoretical analysis. This paper is helpful to better understand the effects of sensor position errors on wideband beamformers and useful in microphone array design.


10 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BXBing Xue
Bing Xue
WSWen Shi
Wen Shi
SCSanjay Haresh Chotirmall
Sanjay Haresh Chotirmall
VKVivian Ci Ai Koh
Vivian Ci Ai Koh
YAYi Yang Ang
Yi Yang Ang
Wee SerWee Ser
Wee Ser
Smart wearable sensors are essential for continuous health-monitoring applications and detection accuracy of symptoms and energy efficiency of processing algorithms are key challenges for such devices. While several machine-learning-based algorithms for the detection of abnormal breath sounds are reported in literature, they are either too computationally expensive to implement into a wearable device or inaccurate in multi-class detection. In this paper, a kernel-like minimum distance classifier (K-MDC) for acoustic signal processing in wearable devices was proposed. The proposed algorithm was tested with data acquired from open-source databases, participants, and hospitals. It was observed that the proposed K-MDC classifier achieves accurate detection in up to 91.23% of cases, and it reaches various detection accuracies with a fewer number of features compared with other classifiers. The proposed algorithm’s low computational complexity and classification effectiveness translate to great potential for implementation in health-monitoring wearable devices.

19 July 2018 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
KHK.J. Hong
K.J. Hong
SES. Essid
S. Essid
Wee SerWee Ser
Wee Ser
DFD.C.-G. Foo
D.C.-G. Foo