Joshua Haworth

Dr. Joshua Haworth

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2010 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
ASAdam J. Strang
Adam J. Strang
JHJoshua Haworth
Joshua Haworth
MHMathias Hieronymus
Mathias Hieronymus
MWMark Walsh
Mark Walsh
LSL. James Smart
L. James Smart

28 July 2020 in Perceptual and Motor Skills
Verified
Journal Article
Closed access
PDF file
MWMark Walsh
Mark Walsh
CCCaroline Church
Caroline Church
AHAudrey Hoffmeister
Audrey Hoffmeister
DSDean Smith
Dean Smith
JHJoshua Haworth
Joshua Haworth
Measurements of postural sway are used to assess physiological changes due to therapy or sport training, or to describe group differences based on activity history or disease status. Portable force plates have been widely adopted for this purpose, leading us in this study to validate with linear and nonlinear metrics the posturographic data derived from both a portable plate (Natus) when compared to an in-ground plate (Bertec). Twenty participants stood on each plate for two trials each, with and without a foam perturbation and with and without eyes open on each surface. We calculated measures of path length, range, root mean squares, sample entropy, and correlation dimensions from center of pressure traces on each plate. An intraclass correlation coefficient across trials from each plate in each condition indicated satisfactory overall reliability (ICC consistency), supporting the use of either plate for postural sway research and interventions. Additionally, our results generally supported common validity (ICC absolute agreement), though, the specific degree of similarity differed for each of the tested metrics of postural sway, especially when considering whether or not data was filtered. For situations in which participants cannot visit a laboratory (e.g. performing athletes, community dwelling clinical patients, and virus risk concerns) an in-home portable force plate is a trusted and valuable data collection tool.

1 January 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
DRDaniel M. Russell
Daniel M. Russell
JHJoshua Haworth
Joshua Haworth

1 November 2021 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
DGDaniel James Goble
Daniel James Goble
NCNathan O Conner
Nathan O Conner
MNMichael R Nolff
Michael R Nolff
JHJoshua Haworth
Joshua Haworth
BKBradley J Kendall
Bradley J Kendall
Background: Postural control is critical for body sway control and is subserved by three sources of sensory feedback (ie, vision, proprioception and vestibulation). A method for determining the relative contribution of each sensory feedback source to postural control is the modified clinical test of sensory integration and balance for the balance tracking system (BTrackS). However, this method has not yet been evaluated for test–retest reliability. Purpose: To determine the test–retest reliability of the modified clinical test of sensory integration and balance protocol for the BTrackS across multiple time intervals. Methods: Three groups of healthy young adults performed the BTrackS modified clinical test of sensory integration and balance protocol four times separated by either one day, one week or one month. Within each time duration group, and condition, differences in total center of pressure path length were determined from one test session to the next and intra class correlation coefficient categorizations were made. Results: In all but one case, no significant difference in performance was seen from one testing session to the next. The one significant difference found was a decrease in total center of pressure path length from day 1 to day 2 in the vestibular condition of the group tested daily. Intra class correlation coefficient results largely indicated fair-good reliability across time durations and test conditions. Conclusion: The present study largely supports use of the BTrackS modified clinical test of sensory integration and balance protocol as a means of probing the sensory contributions to balance performance across multiple time durations.

1 July 2020 in Gait & Posture
Verified
Journal Article
Closed access
JHJoshua Haworth
Joshua Haworth
DGDaniel James Goble
Daniel James Goble
MPMolly Pile
Molly Pile
BKBradley Kendall
Bradley Kendall

12 December 2015 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
DRDaniel M. Russell
Daniel M. Russell
JHJoshua Haworth
Joshua Haworth
CMCesar Martinez-Garza
Cesar Martinez-Garza