Inaccurate subjective seizure counting poses treatment and diagnostic challenges and thus suboptimal quality in epilepsy management. The limitations of existing hospital‐ and home‐based monitoring solutions are motivating the development of minimally invasive, subscalp, implantable electroencephalography (EEG) systems with accompanying cloud‐based software. This new generation of ultra–long‐term brain monitoring systems is setting expectations for a sea change in the field of clinical epilepsy. From definitive diagnoses and reliable seizure logs to treatment optimization and presurgical seizure foci localization, the clinical need for continuous monitoring of brain electrophysiological activity in epilepsy patients is evident. This paper presents the converging solutions developed independently by researchers and organizations working at the forefront of next generation EEG monitoring. The immediate value of these devices is discussed as well as the potential drivers and hurdles to adoption. Additionally, this paper discusses what the expected value of ultra–long‐term EEG data might be in the future with respect to alarms for especially focal seizures, seizure forecasting, and treatment personalization.
Permutation entropy (PE) has been widely exploited to measure the complexity of the electroencephalogram (EEG), especially when complexity is linked to diagnostic information embedded in the EEG. Recently, the authors proposed a spatial-temporal analysis of the EEG recordings of absence epilepsy patients based on PE. The goal here is to improve the ability of PE in discriminating interictal states from ictal states in absence seizure EEG. For this purpose, a parametrical definition of permutation entropy is introduced here in the field of epileptic EEG analysis: the permutation Rényi entropy (PEr). PEr has been extensively tested against PE by tuning the involved parameters (order, delay time and alpha). The achieved results demonstrate that PEr outperforms PE, as there is a statistically-significant, wider gap between the PEr levels during the interictal states and PEr levels observed in the ictal states compared to PE. PEr also outperformed PE as the input to a classifier aimed at discriminating interictal from ictal states.
Purpose. We provide a comprehensive verification of a new subcutaneous EEG recording device which promises robust and unobtrusive measurements over ultra-long time periods. The approach is evaluated against a state-of-the-art surface EEG electrode technology.Materials and Methods. An electrode powered by an inductive link was subcutaneously implanted on five subjects. Surface electrodes were placed at sites corresponding to the subcutaneous electrodes, and the EEG signals were evaluated with both quantitative (power spectral density and coherence analysis) and qualitative (blinded subjective scoring by neurophysiologists) analysis.Results. The power spectral density and coherence analysis were very similar during measurements of resting EEG. The scoring by neurophysiologists showed a higher EEG quality for the implanted system for different subject states (eyes open and eyes closed). This was most likely due to higher amplitude of the subcutaneous signals. During periods with artifacts, such as chewing, blinking, and eye movement, the two systems performed equally well.Conclusions. Subcutaneous measurements of EEG with the test device showed high quality as measured by both quantitative and more subjective qualitative methods. The signal might be superior to surface EEG in some aspects and provides a method of ultra-long term EEG recording in situations where this is required and where a small number of EEG electrodes are sufficient.