The image-type angular displacement measurement method based on linear image recognition has garnered attention because of its higher frequency response, strong fault tolerance, and high robustness. In the small-size image angular displacement measuring device, due to the limited pixel size, the circular grating cannot place more lines when realizing single-channel absolute coding recognition on a small diameter grating disk. This leads to larger errors in angular displacement measurement when the line density of the grating disk is low. To improve the measurement accuracy of small-scale displacement, the present work aimed to reduce this error by studying the error compensation method involving low-density grating disks. First, the mechanism of linear image-type angular displacement measurements is described, and a measurement algorithm based on linear scan images is proposed. Second, the measurement error model for low-density grating disks is established according to the proposed measurement algorithm. Third, a simplified error compensation algorithm based on a harmonic model is developed. Finally, simulations and experiments are performed to verify the performance of the proposed algorithm. Simulation results show that the developed harmonic compensation algorithm can effectively reduce the error caused by the low-density circular grating. When the proposed error compensation algorithm is applied to a grating disk with a 62 mm diameter and 2 N lines, the measurement accuracy is improved from 8.14” to 4.78”. The proposed error compensation algorithm can significantly improve the accuracy of linear image-type angular displacement measurements involving low-density grating disks, and the results presented herein laid a foundation for improving the accuracy and engineering applicability of angular displacement measurement technology.
This paper proposes a novel error compensation arithmetic based on dual imaging detectors which can eliminate errors caused by grating eccentricity. First, we built an error model and analyzed the error change current. Next, we deduced the error compensation arithmetic and established the dual-image-detector-based method. Finally, we conducted a series of experiments to test the performance of this arithmetic. The test results showed that, we achieved standard error deviation of 6.33" and grating diameter of only 38 mm. This arithmetic outperforms the single detector and is far superior to the traditional method. The results presented here may provide a theoretical foundation for further research on angle-displacement measurement.
Displacement measurement based on an image recognition algorithm has more advantages in the field of displacement measurement. Due to the uncertainty of image location, the accuracy of the displacement measurement algorithm studied in the previous stage is limited. To improve the accuracy of image-type displacement measurement, a high-precision displacement measurement algorithm based on depth fusion of the grating projection pattern is proposed. First, a line-scan image sensor and parallel light source are placed on both sides of the calibration grating. The marking pattern on the calibration grating is projected onto the image sensor through illumination of the parallel light source to realize the projection imaging. Then, the centroid algorithm is used to calculate the centroid of each line in the collected image, and the mean value of the centroid group is determined. Finally, a linear function is used to fit multiple centroids to calculate the endpoints of the subdivision region, and the subdivision operation is carried out according to a ratio algorithm. To test the performance of the proposed algorithm, a linear displacement measurement device with a 250 mm range and an angular displacement measurement device with a 100 mm diameter grating are both used for experiments. After testing, the linear measurement accuracy of the proposed algorithm is improved from 4.63 to 1.26 µm, and the angular displacement measurement accuracy is enhanced from 8.87 to . The research in this paper provides a theoretical basis for high-performance displacement measurement.
As the feedback link of a numerical control system, the measurement accuracy of absolute angular displacement measurements directly affects the control performance of a numerical control system. In previous research, angular displacement measurements based on dual image sensors can achieve higher measurement performance. However, the elimination of harmonic error by the dual image sensor is still limited. For this reason, this paper proposes an image-type angular displacement measurement method based on self-correction error compensation of three image sensors. First, the mathematical model of harmonic error is established, and the shortcomings of using dual image sensors to compensate the error are analyzed. Then, a high precision angular displacement measurement method based on three image sensors is proposed. Finally, the self-correction error compensation method of three image sensors is applied to the angular displacement measurement system, and the measurement performance is verified. The experimental results show that a measurement accuracy of can be achieved on the circular grating with a diameter of 96 mm. In contrast, the dual image sensor can only achieve a measurement accuracy of . It is concluded that the odd number of image sensors can achieve higher measurement accuracy than the even number. This research lays a foundation for the realization of high precision image angular displacement measurement.