Lidia Strigari

Dr. Lidia Strigari

Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2019 in Journal of Experimental & Clinical Cancer Research
Verified
Journal Article
Open access
PDF file
RLRossella Loria
Rossella Loria
CGClaudia Giliberti
Claudia Giliberti
ABAngelico Bedini
Angelico Bedini
RPRaffaele Palomba
Raffaele Palomba
Giulio CaraccioloGiulio Caracciolo
Giulio Caracciolo
LSLidia Strigari
Lidia Strigari
The possibility to combine Low Intensity UltraSound (LIUS) and Nanoparticles (NP) could represent a promising strategy for drugs delivery in tumors difficult to treat overcoming resistance to therapies. On one side the NP can carry drugs that specifically target the tumors on the other the LIUS can facilitate and direct the delivery to the tumor cells. In this study, we investigated whether Very Low Intensity UltraSound (VLIUS), at intensities lower than 120 mW/cm2, might constitute a novel strategy to improve delivery to tumor cells. Thus, in order to verify the efficacy of this novel modality in terms of increase selective uptake in tumoral cells and translate speedily in clinical practice, we investigated VLIUS in three different in vitro experimental tumor models and normal cells adopting three different therapeutic strategies. VLIUS at different intensities and exposure time were applied to tumor and normal cells to evaluate the efficiency in uptake of labeled human ferritin (HFt)-based NP, the delivery of NP complexed Firefly luciferase reported gene (lipoplex-LUC), and the tumor-killing of chemotherapeutic agent. Specifically, we found that specific VLIUS intensity (120 mW/cm2) increases tumor cell uptake of HFt-based NPs at specific concentration (0.5 mg/ml). Similarly, VLIUS treatments increase significantly tumor cells delivery of lipoplex-LUC cargos. Furthermore, of interest, VLIUS increases tumor killing of chemotherapy drug trabectedin in a time dependent fashion. Noteworthy, VLIUS treatments are well tolerated in normal cells with not significant effects on cell survival, NPs delivery and drug-induced toxicity, suggesting a tumor specific fashion. Our data shed novel lights on the potential application of VLIUS for the design and development of novel therapeutic strategies aiming to efficiently deliver NP loaded cargos or anticancer drugs into more aggressive and unresponsive tumors niche.

12 January 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
HLHugo Levillain
Hugo Levillain
OBOreste Bagni
Oreste Bagni
CDChristophe M. Deroose
Christophe M. Deroose
ADArnaud Dieudonné
Arnaud Dieudonné
SGSilvano Gnesin
Silvano Gnesin
PFPatrick Flamen
Patrick Flamen
Purpose: A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. Methods: A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%–79%, no agreement ≤ 49%). Results: Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100–120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). Conclusion: Practitioners are encouraged to work towards adoption of these recommendations.

1 September 2010 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
GAGiorgio Arcangeli
Giorgio Arcangeli
BSBiancamaria Saracino
Biancamaria Saracino
SGSara Gomellini
Sara Gomellini
MPMaria Grazia Petrongari
Maria Grazia Petrongari
SAStefano Arcangeli
Stefano Arcangeli
LSLidia Strigari
Lidia Strigari

11 June 2014 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
LSLidia Strigari
Lidia Strigari
MKMark Konijnenberg
Mark Konijnenberg
CCCarlo Chiesa
Carlo Chiesa
MBManuel Bardies
Manuel Bardies
YDYong Du
Yong Du
GFGlenn Flux
Glenn Flux

18 August 2010 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
LSLidia Strigari
Lidia Strigari
RSRosa Sciuto
Rosa Sciuto
SRSandra Rea
Sandra Rea
LCLivio Carpanese
Livio Carpanese
GPGiuseppe Pizzi
Giuseppe Pizzi
CMCarlo Ludovico Maini
Carlo Ludovico Maini
Radioactive 90Y-selective internal radiation (SIR) sphere therapy is increasingly used for the treatment of nonresectable hepatocellular carcinoma (HCC). However, the maximum delivered dose is limited by severe injury to the nontarget tissue, including liver parenchyma. Our study aimed to implement radiobiologic models for both tumor control probability (TCP) and normal-tissue complication probability (NTCP) to describe more effectively local response and the liver toxicity rate, respectively. Methods: Patients with documented HCC, adequate bone marrow parameters, and regular hepatic and pulmonary function were eligible for the study. Patients who had pulmonary shunt greater than 20% of 99mTc-labeled macroaggregated albumin or any uncorrectable delivery to the gastrointestinal tract, reverse blood flow out of the liver, or complete portal vein thrombosis were excluded. Patients received a planned activity of the 90Y-SIR spheres, determined using the empiric body surface area method. The dose distribution was determined using posttreatment (3-dimensional) activity distribution and Monte Carlo dose voxel kernel calculations, and the mean doses to healthy liver and tumor were calculated for each patient. Response was defined according to Response Evaluation Criteria in Solid Tumors (RECIST) and recommendations of the European Association for the Study of the Liver (EASL). Criteria were used to assess possible liver toxicities. The parameters of TCP and NTCP models were established by direct maximization of the likelihood. Results: Seventy-three patients were treated. With an average dose of 110 Gy to the tumor, complete or partial response was observed in 74% and 55% of patients according to the EASL guideline and RECIST, respectively, and the predicted TCPs were 73% and 55%, respectively. With a median liver dose of 36 Gy (range, 6–78 Gy), the ≥grade 2 (G2), ≥grade 3 (G3), and ≥grade 4 (G4) liver toxicities were observed in 32% (23/73), 21% (15/73), and 11% (8/73) of patients, respectively. The parameters describing the ≥G2 liver toxicity data using the NTCP model were a tolerance dose of the whole organ leading to a 50% complication probability of 52 Gy (95% confidence interval, 44–61 Gy) and a slope of NTCP versus dose of 0.28 (95% confidence interval, 0.18–0.60), assuming n = 1. Conclusion: The radiobiologic approach, based on patient-specific dosimetry, could improve the 90Y-microsphere therapeutic approach of HCC, maintaining an acceptable liver toxicity.

1 December 2012 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
SAStefano Arcangeli
Stefano Arcangeli
LSLidia Strigari
Lidia Strigari
SGSara Gomellini
Sara Gomellini
BSBiancamaria Saracino
Biancamaria Saracino
MPMaria Grazia Petrongari
Maria Grazia Petrongari
GAGiorgio Arcangeli
Giorgio Arcangeli