Andres Patrignani

Dr. Andres Patrignani

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2025 in Engineering Applications of Artificial Intelligence
Verified
Journal Article
Closed access
ABAmirsalar Bagheri
Amirsalar Bagheri
APAndres Patrignani
Andres Patrignani
Behzad GhanbarianBehzad Ghanbarian
Behzad Ghanbarian
DPDavood B. Pourkargar
Davood B. Pourkargar

15 October 2024 in Soil Science Society of America Journal
Verified
Journal Article
Open access
SCSofía Cominelli
Sofía Cominelli
LRLeonardo D. Rivera
Leonardo D. Rivera
WBWilliam G. Brown
William G. Brown
TOTyson Ochsner
Tyson Ochsner
APAndres Patrignani
Andres Patrignani
The TEROS 10 and TEROS 12 are widely used capacitance‐based sensors for measuring volumetric water content (), but few systematic studies of the measurement volume and accuracy of these sensors have been published. The objectives of this study were to (1) calibrate and validate these sensors in mineral soils, (2) determine the sensing volume of each sensor, and (3) evaluate the temperature sensitivity of the sensors. Both sensors were calibrated in the laboratory using columns of packed soil at multiple moisture levels from air‐dry to near saturation. Sensors were validated using additional laboratory and field measurements. The sensing volume was determined by quantifying the response of raw sensor outputs while increasing the level of oven‐dry sand, moist sand (0.100 cm 3 cm −3 ), or water around the sensor in the radial and axial directions. Temperature sensitivity was tested in controlled conditions over a range of temperatures from 2°C to 40°C using encapsulated sensors in packed soil columns at constant . Linear calibration models resulted in mean absolute error ≤0.030 cm 3 cm −3 for both sensors during laboratory and field validations. In moist sand, the sensing volume contributing 95% of the maximum sensor response was 439 cm 3 for the TEROS 10 and 423 cm 3 for the TEROS 12. Both sensors exhibited changes in of ≤0.02 cm 3 cm −3 when subjected to a temperature change from 2°C to 40°C. For the soils considered here, both sensors demonstrated accuracy that is likely sufficient for a variety of agricultural and hydrological applications.

7 July 2021 in Frontiers in Water
Verified
Journal Article
Open access
APAndres Patrignani
Andres Patrignani
TOTyson E. Ochsner
Tyson E. Ochsner
BMBenjamin Montag
Benjamin Montag
SBSteven Bellinger
Steven Bellinger
During the past decade, cosmic-ray neutron sensing technology has enabled researchers to reveal soil moisture spatial patterns and to estimate landscape-average soil moisture for hydrological and agricultural applications. However, reliance on rare materials such as helium-3 increases the cost of cosmic-ray neutron probes (CRNPs) and limits the adoption of this unique technology beyond the realm of academic research. In this study, we evaluated a novel lower cost CRNP based on moderated ultra-thin lithium-6 foil (Li foil system) technology against a commercially-available CRNP based on BF3 (boron trifluoride, BF-3 system). The study was conducted in a cropped field located in the Konza Prairie Biological Station near Manhattan, Kansas, USA (325 m a.s.l.) from 10 April 2020 to 18 June 2020. During this period the mean atmospheric pressure was 977 kPa, the mean air relative humidity was 70%, and the average volumetric soil water content was 0.277 m3 m−3. Raw fast neutron counts were corrected for atmospheric pressure, atmospheric water vapor, and incoming neutron flux. Calibration of the CRNPs was conducted using four intensive field surveys (n > 120), in combination with continuous observations from an existing array of in situ soil moisture sensors. The time series of uncorrected neutron counts of the Li foil system was highly correlated (r2 = 0.91) to that of the BF-3 system. The Li foil system had an average of 2,250 corrected neutron counts per hour with an uncertainty of 2.25%, values that are specific to the instrument size, detector configuration, and atmospheric conditions. The estimated volumetric water content from the Li foil system had a mean absolute difference of 0.022 m3 m−3 compared to the value from the array of in situ sensors. The new Li foil detector offers a promising lower cost alternative to existing cosmic-ray neutron detection devices used for hectometer-scale soil moisture monitoring.

20 September 2021 in Vadose Zone Journal
Verified
Journal Article
Open access
PDF file
PRPedro R. Rossini
Pedro R. Rossini
Ignacio Antonio CiampittiIgnacio Antonio Ciampitti
Ignacio Antonio Ciampitti
THTrevor Hefley
Trevor Hefley
APAndres Patrignani
Andres Patrignani
Soil moisture information is a key variable for guiding in‐season management decisions in rainfed and irrigated agricultural systems. However, methods for deciding the number and location of soil moisture sensors (SMS) per field still remain poorly explored in the scientific literature. The goal of this study was to evaluate a quantitative framework based on soil moisture‐based management zones (MZs) to determine the minimum number and tentative deployment location of SMS. Multiple spatially intensive ( n  > 100 observations) surveys of near‐surface (0–12 cm) soil moisture were conducted during the fallow periods and early growing seasons of 2017, 2018, and 2019 on three agricultural fields using a calibrated handheld soil water reflectometer. The fuzzy C ‐means (FCM) clustering method was used to delineate MZs based on the soil moisture surveys, and the silhouette clustering evaluation method was used to identify the optimal number of MZs per field. Then, a sensor location index that considered the distance to the MZ boundaries and the FCM membership grade was developed to identify the tentative optimal deployment location of SMS. The proposed method effectively identified field areas with distinct soil moisture regimes and revealed the complex soil moisture spatial patterns that were not captured with elevation or soil texture alone. Dividing the fields using soil moisture‐based MZ reduced the intrazone soil moisture spatial variability by about 50% compared with that of the entire field. In the three studied fields, a total of two SMS were sufficient to capture the salient soil moisture spatial regimes.

14 March 2022 in Vadose Zone Journal
Verified
Journal Article
Open access
APAndres Patrignani
Andres Patrignani
TOTyson Ochsner
Tyson Ochsner
LFLei Feng
Lei Feng
DDDon Dyer
Don Dyer
PRPedro R. Rossini
Pedro R. Rossini
In this study, we tested soil water reflectometers represented by the CS65x series soil water reflectometers. The objectives were to (a) quantify the sensing volume of the CS65x sensors, (b) evaluate common univariate and multivariate calibration models, and (c) assess the implications of using uncalibrated sensors. The support volume was determined by analyzing the response of the bulk dielectric permittivity to a changing amount of surrounding media in the radial and axial directions of the sensor. Calibration models were tested using a dataset of ∼300 soil samples spanning nine soil textural classes. A time series of rootzone soil water storage recorded in two contrasting soils and two intensive ( n ∼300) spatial surveys of near‐surface soil moisture were used to quantify the implications of using uncalibrated sensors. The electromagnetic signal of CS655 was concentrated within a ∼3.5‐cm radius around the center of the sensor rods. Univariate and multivariate calibration equations reduced the mean absolute error (MAE) in soil moisture observations by ∼40% compared with factory default equations. Uncalibrated sensors did not change the pattern of soil moisture temporal dynamics but resulted in a strong bias in soil water storage in a silty clay loam soil and altered the soil moisture spatial patterns obtained in moderate to wet field conditions in a silty clay soil. The CS655 sensor with the Kargas and Soulis calibration equation (MAE = 0.026 cm 3 cm −3 ) appears to be an acceptable candidate for deployment in soil moisture monitoring networks seeking to avoid site‐specific sensor calibrations.

1 November 2018 in Journal of Hydrology
Verified
Journal Article
Closed access
APAndres Patrignani
Andres Patrignani
TOTyson Ochsner
Tyson Ochsner