Virinder Kumar

Dr. Virinder Kumar

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2020 in Materials and Manufacturing Processes
Verified
Journal Article
Closed access
MPMainak Pal
Mainak Pal
VKVirinder Kumar
Virinder Kumar
Shankar SehgalShankar Sehgal
Shankar Sehgal
HKHarmesh Kumar
Harmesh Kumar
Kuldeep SAXENAKuldeep SAXENA
Kuldeep SAXENA
ABAshok K. Bagha
Ashok K. Bagha
In this study, the microwave hybrid heating process has been exploited to produce optimized joints of SS304/SS316. Three input parameters: materials of the specimens to be joined (X), grain-size of filler powder (Y), and processing time (Z) have been investigated to see their effects on two major joint properties: micro-hardness (P) and micro-tensile strength (Q). Welded joints of specimens have gone through mechanical characterization via Vicker’s micro-hardness tests and also the micro-tensile strength examinations. Outcomes have been used further for finding optimal settings of input parameters to achieve the best mechanical properties of joints. Grain-size of filler material is the most significant parameter; followed by specimen material. On the other hand, process time has little influence on output parameters within the small incremental time range of only 60 s considered during this work. SS304-SS304 (X1) specimen materials with 70 nm (Y1) filler powder at 360 s (Z1) processing time input settings help in achieving optimal micro-hardness (Poptimal) and micro-tensile strength (Qoptimal). Microstructure test results of the developed joints reveal the formation of dense metallic microstructures across the joining region which justifies the reason for higher micro-hardness and micro-tensile strength of the joint region.

24 June 2021 in Advances in Materials and Processing Technologies
Verified
Journal Article
Closed access
VKVirinder Kumar
Virinder Kumar
Shankar SehgalShankar Sehgal
Shankar Sehgal
In this paper, selective microwave hybrid heating (SMHH) based microwave joining of SS2205 specimens has been performed. SS2205 specimens have been successfully joined through SMHH-based joining method without using any filler material at 300 seconds of exposure time. The exposure time of 300 seconds has been found through trial experiments using insulation brick of thickness 6.5 cm and refractory brick of thickness 3.1 cm. The cost of the joining process was significantly reduced due to the absence of filler material. The charcoal powder which is a microwave absorber was used to commence as well as stimulate the heating process. The charcoal powder was fed through the vertical cavity of diameter 8 mm over the joint region. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) tests have been carried out to examine the physical characteristics of the fabricated joints. The joints were also mechanically characterised through micro-hardness tests and tensile tests. Average microhardness at joint region was 410 HV, whereas microhardness of the original specimen was 252 HV. Average tensile strength and percent elongation of the joints was 223 MPa and 11.9%, respectively.


1 March 2021 in Metal Powder Report
Verified
Journal Article
Closed access
VKVirinder Kumar
Virinder Kumar
Shankar SehgalShankar Sehgal
Shankar Sehgal

21 March 2025 in Pest Management Science
Verified
Journal Article
Closed access
GPGuru PN
Guru PN
DSDhritiman Saha
Dhritiman Saha
YKYogesh B Kalnar
Yogesh B Kalnar
MSMonika Sharma
Monika Sharma
RZRUCHIKA ZALPOURI
RUCHIKA ZALPOURI
NSNivedita Shettigar
Nivedita Shettigar

1 December 2025 in ECS Journal of Solid State Science and Technology
Verified
Journal Article
Closed access
PPPrachi Palta
Prachi Palta
APAastha Palta
Aastha Palta
VKVirinder Kumar
Virinder Kumar
Recent developments in nano-materials have re-architected the frontiers of solid-state sensor design, enabling high sensitivity, selectivity, and sustainability across a broad spectrum of real-world applications. This review summarises the advances in nanomaterial-engineered sensors, including the connection between material structure and functional mechanisms, as well as the device’s performance. Doped metal-oxide semiconductors (SnO 2 or ZnO, or WO 3 ) or polyoxometalates or MXenes exhibit an improved speed of charge transfer, low temperatures, and selectivity. Hydrophilic polymers, biocomposites and MXene hybrid sensors based on impedance and ionic humidity are flexible, fast-reactive and self-powered. Piezoelectric and photoacoustic transduction, based on ferroelectric ceramics, PVDF, and bio-based polymers such as PLA, chitosan, and cellulose, provides a platform for sustainable and energy-harvesting wearable devices and implants. The combination of electrochemical materials and biodegradable materials also enhances environmentally friendly sensor technologies. Multimodal sensing is adopting new architectures developed using adaptive calibration and intelligent data interpretation based on new artificial intelligence. As observed in the review, the compositional tuning, heterostructuring, and nanoscale morphology are used to control the science of bridge materials and the engineering of functional devices. The vision for this area is to develop fully autonomous, power-driven, and recyclable sensor ecosystems that can seamlessly integrate into Internet of Things (IoT) networks, enabling continuous monitoring of the environment, health, and industrial status with minimal human intervention and environmental impact. Lastly, the existing challenges, such as interference from humidity, signal drift, and the possibility of large-scale manufacturability, are not only documented but also addressed through the opportunities presented by multifunctional sensor systems, autonomous sensor systems, and recyclable sensor systems of the future. Future developmental trends include the integration of machine learning algorithms with multimodal sensor arrays to provide real-time adaptive analytics, the development of biodegradable and bioresorbable platforms for transient implantable diagnostics, and the development of flexible, skin-conformal architectures for precision medicine and personalized wearable health monitoring. This comprehensive evaluation offers a unique perspective on how nanomaterial-engineered solid-state sensors can be utilized to support the development of next-generation, sustainable, and intelligent technologies.