This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances.
1 January 2020 in Brazilian Journal of Development
Uma proposta de análise em CFD do fluxo de conhecimento aplicado nas áreas das engenharias / A CFD analysis proposal of the knowledge flow applied in the engineering areas
O objetivo deste trabalho foi desenvolver um sistema de monitoramento para analisar os agentes estressores no ambiente de aprendizagem. Entre os agentes estressores que mais afetam o desempenho cognitivo e produtividade, pode-se destacar a temperatura, ruído, iluminação e concentração de CO2. A aquisição das variáveis temperatura, ruído e iluminância foi realizada por meio de sensores calibrados e de um sistema de aquisição de dados de baixo custo (ESP 32), porém com acesso wireless, permitindo monitoramento e integração IoT (do inglês, Internet of Things). No painel back-end as variáveis passam por uma correlação com coeficientes obtidos experimentalmente. Além disso, o tempo amostral das variáveis podem ser definidos de acordo com a preferência do usuário em uma faixa pré-determinada. A ferramenta também dispõe de um módulo de monitoramento do nível de concentração de CO2 no ambiente. Caso este nível ultrapasse o limite estabelecido por norma, o sistema emite um alerta para o usuário, garantido que os alunos estudem sob níveis de dióxido de carbono que não comprometam a concentração ou qualquer outro dano cognitivo relacionado a aprendizagem. Como resultado, foi possível avaliar os dos agentes estressores em um ambiente de aprendizagem e inovação.
This study presents a transient two-dimensional model devised to predict frost build-up, pressure drop, and sensible and latent heat transfer rates in tube-fin evaporators, commonly used in ‘frost-free’ refrigerators. Based on the first principles of mass, momentum, and energy conservation for the airflow and the frost layer, the model accurately simulates evaporator blockage over time. Furthermore, it incorporates the interaction between the heat exchanger air-side impedance and the fan performance characteristic curve, using an iterative fluid-dynamic sub-model that predicts airflow reduction and redistribution in an evaporator with three fin densities. Frost accretion experiments were conducted using a purpose-built test setup consisting of a bottom-mount refrigerator cabinet maintained at controlled temperature and humidity in both the fresh and frozen-food compartments. Model validation demonstrated that the predicted results closely matched experimental observations. The results show that localized frost accumulation at fin density transitions causes severe airflow blockage, resulting in a 75% reduction in effective heat transfer area due to uneven air distribution. Finally, an analysis of two dimensionless competing indices demonstrates that fin density selection involves a critical trade-off between the initial cooling capacity and long-term frost resilience.