We compared scatter correction (SC) in single-photon emission computed tomography (SPECT) images using effective scatter source estimation (ESSE) and the triple-energy window (TEW) method. We acquired 99mTc and 123I images of brain, myocardial, and performance phantoms containing rods with different diameters. We assessed contrast ratios (CRs) and ROI-based noise metrics (coefficient of variation, signal-to-noise ratio, and contrast-to-noise ratio [CNR] ). Under 99mTc, ESSE yielded higher CRs than TEW across all phantoms (mean difference 0.04, range 0.01–0.05) and produced the highest CNR in the myocardial phantom, improving the conspicuousness of the simulated defect. Under 123I, CR differences between ESSE and TEW were small and inconsistent (performance phantom: −0.04 to 0.06; brain phantom: −0.01 to 0.00). A Monte Carlo simulation (point source in air) showed substantial photopeak window penetration for cardiac high-resolution collimators (40.0%) but low penetration for medium-energy general-purpose collimators (5.1%), supporting photopeak contamination as a contributor to the 123I findings and potentially attenuating the apparent advantage of model-based SC that does not explicitly account for penetration photons. These findings suggest that SC selection should consider the radionuclide and imaging target and that ESSE might be a reasonable option for 99mTc myocardial imaging under the settings examined.

1 October 2025 in Radioprotection
Verified
Journal Article
Open access
PDF file
SHShota Hosokawa
Shota Hosokawa
ANA. Nakamura
A. Nakamura
HOH. Ose
H. Ose
MOMinoru Osanai
Minoru Osanai
RMRyutaro Mori
Ryutaro Mori
YTYasuyuki Takahashi
Yasuyuki Takahashi
In this study, we evaluated the educational effectiveness of training by reviewing recorded data on contamination survey techniques and real-time display feedback. An optical flow (OF) sensor and a distance sensor were used to measure the speed and distance, respectively. The sensors were mounted on a radiation measuring device, and the contamination survey techniques of the 12 participants were recorded. The recorded data and real-time technique feedback was used to conduct training, after which the participants performed contamination surveys once more. Speed and distance both significantly decreased after training, with speed dropping from 4.70 to 3.45 cm s −1 and distance decreasing from 1.16 to 0.90 cm. Additionally, variations during surveys showed a significant reduction.