Koichi Okuda

Dr. Koichi Okuda

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2014 in Journal of Nuclear Cardiology
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
MYMana Yoshimura
Mana Yoshimura
SMShinro Matsuo
Shinro Matsuo
HWHiroshi Wakabayashi
Hiroshi Wakabayashi
SKSeigo Kinuya
Seigo Kinuya
The heart-to-mediastinum ratio (HMR) of 123I-metaiodobenzylguanidine (MIBG) showed variations among institutions and needs to be standardized among various scinticamera-collimator combinations.

20 February 2016 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
NMNaoya Matsumoto
Naoya Matsumoto
TKTokuo Kasai
Tokuo Kasai
SMShinro Matsuo
Shinro Matsuo
KKKeisuke Kiso
Keisuke Kiso
KOKoichi Okuda
Koichi Okuda
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of 123I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.

1 February 2011 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
KOKoichi Okuda
Koichi Okuda
KNKenichi Nakajima
Kenichi Nakajima
THTetsuo Hosoya
Tetsuo Hosoya
TITakehiro Ishikawa
Takehiro Ishikawa
TKTakahiro Konishi
Takahiro Konishi
SKSeigo Kinuya
Seigo Kinuya

19 October 2011 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
SMShinro Matsuo
Shinro Matsuo
MYMitsuhiro Yoshita
Mitsuhiro Yoshita
JTJunichi Taki
Junichi Taki
SKSeigo Kinuya
Seigo Kinuya
This study was performed to demonstrate that the results obtained with a calibration phantom could be used as a tool for standardizing measurement of heart to mediastinum (H/M) ratio in cardiac metaiodobenzylguanidine (MIBG) imaging. Images of the phantom containing 123I-MIBG were acquired on the cameras in 10 hospitals (11 camera types) to determine the relationship between H/M ratios using different collimators: low-energy (LE) and medium-energy (ME)/low–medium-energy (LME) collimators. The effect of standardization on the ME-comparable H/M ratio was examined in two settings: a Japanese standard MIBG database (n = 62) and multicentre studies (n = 49). In a multicentre study, probable Alzheimer’s disease (AD, n = 18) and probable dementia with Lewy bodies (DLB, n = 31) were studied and standardized by the calibration phantom method. Linear regression equations between LE and ME collimators were obtained for the phantom study in all institutions. When the H/M ratio with an LE collimator was corrected based upon the calibration phantom, the corrected values were comparable to those obtained using ME collimators. The standard database also exhibited a normal distribution after standardization as determined by skewness and goodness-of-fit test. A mixture of the populations by LE and ME collimators showed significant separation of AD and DLB groups (F ratio = 24.9 for the late H/M), but the corrected values resulted in higher F ratios for both early and late H/M (F ratio = 34.9 for the late H/M). Standardization of H/M ratios by the heart-chest calibration phantom method is feasible among different collimator types. This method could be practically used for multicentre comparison of H/M ratios.

9 February 2016 in Journal of Nuclear Cardiology
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
SMShinro Matsuo
Shinro Matsuo
KKKeisuke Kiso
Keisuke Kiso
SKSeigo Kinuya
Seigo Kinuya
EGErnest V. Garcia
Ernest V. Garcia
Purpose Left ventricular (LV) phase dyssynchrony parameters based on gated myocardial perfusion imaging varied among software programs. The aim of this study was to determine normal ranges and factors affecting phase parameters. Methods Normal databases were derived from the Japanese Society of Nuclear Medicine working group (n = 69). The programs were Emory Cardiac Toolbox with SyncTool (ECTb), Quantitative Gated SPECT (QGS), Heart Function View (HFV), and cardioREPO (cREPO); parameters of phase standard deviation (PSD), 95% bandwidth, and entropy were compared with parameters with ECTb as a reference. Results PSD (degree) was 5.3 ± 3.3 for QGS (P < .0001), 5.4 ± 2.5 for HFV (P < .0001), and 10.3 ± 3.2 for cREPO (P = n. s.) compared with 11.5 ± 5.5 for ECTb. Phase bandwidth with three programs differed significantly from ECTb. Gender differences were significant for all programs, indicating larger variation in males. After adjustment of LV volumes between genders, the difference disappeared except for QGS. The phase parameters showed wider variations in patients with the lower ejection fraction (EF) and larger LV volumes, depending on software types. Conclusion Based on normal ranges of phase dyssynchrony parameters in four software programs, dependency on genders, LV volume, and EF should be considered, indicating the need for careful comparison among different software programs.

26 September 2017 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
TKTakashi Kudo
Takashi Kudo
TNTomoaki Nakata
Tomoaki Nakata
KKKeisuke Kiso
Keisuke Kiso
TKTokuo Kasai
Tokuo Kasai
LELars Edenbrandt
Lars Edenbrandt
Artificial neural networks (ANN) might help to diagnose coronary artery disease. This study aimed to determine whether the diagnostic accuracy of an ANN-based diagnostic system and conventional quantitation are comparable.