Katie Powell

Ms. Katie Powell


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KPKatie Powell
Katie Powell
AAAhmad Amer
Ahmad Amer
ZGZornitza Glavcheva-Laleva
Zornitza Glavcheva-Laleva
JWJenny Williams
Jenny Williams
CFCaomhnad O’flaherty Farrell
Caomhnad O’flaherty Farrell
CHCatherine Holt
Catherine Holt
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. The 30 s Sit-to-Stand (STS) and Timed-Up-and-Go (TUG) are clinical frailty assessments used alongside gait analysis. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS, and TUG using a waist-worn mobile phone, compared to the Gold Standard 3D marker-based motion capture (Qualisys AB, Sweden) and the Clinical Standard assessment of the STS and TUG test methods. Movement data, recorded simultaneously for 25 healthy volunteers (14 female and 11 male, Age = 31.8 ± 11.6 yrs) in a Biomechanics Laboratory using the Gold Standard system, the Clinical Standard assessments, and MoveLab®, was analyzed using Intraclass Correlation (ICC) and Bland–Altman plots (Python) to quantify the correlations, consistency, and significance across the output parameters. Comparing the methods, the STP consistency ranged from acceptable to good for all the tested parameters (ICC 0.299–0.894). The highest and lowest correlations were cycle time and terminal double support time, respectively. The TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® demonstrated validity and reliability for a range of key movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.

2 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
KPKatie Powell
Katie Powell
AAAhmad Amer
Ahmad Amer
ZGZornitza Glavcheva-Laleva
Zornitza Glavcheva-Laleva
JWJenny Williams
Jenny Williams
CFCaomhnad O’flaherty Farrell
Caomhnad O’flaherty Farrell
CHCatherine Holt
Catherine Holt
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. 30-second-Sit-to-Stand (STS) and Timed-up-and-Go (TUG) are clinical frailty assessments used alongside gait. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS and TUG using a waist-worn mobile phone, compared to ‘gold standard’ 3D marker-based motion capture (Qualisys AB, Sweden). Movement data, recorded simultaneously, for 25 healthy volunteers in a Biomechanics Laboratory, using the gold standard system and MoveLab®, was analysed using Intraclass Correlation (ICC), and Bland-Altman plots (Python), to quantify correlations, consistency, and significance across output parameters. Comparing the methods, STP consistency ranged from acceptable to excellent for all tested parameters (ICC 0.299–0.9). Highest and lowest correlations were cycle time and terminal double support time, respectively. TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® was shown to demonstrate validity and reliability when measuring movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.