Zhuoxin Wang

Mr. Zhuoxin Wang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2025 in Ocean Engineering
Verified
Journal Article
Closed access
YCYao Cui
Yao Cui
SRSami Ur Rehman
Sami Ur Rehman
ZWZhuoxin Wang
Zhuoxin Wang
YCYing Cui
Ying Cui
AAAbid Ali
Abid Ali
MFMuhammad Shameer Faisal
Muhammad Shameer Faisal

2 March 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
ZWZhuoxin Wang
Zhuoxin Wang
LXLihong Xiong
Lihong Xiong
GCGuowu Chen
Guowu Chen
MLMingkang Luo
Mingkang Luo
SZShiliang Zhang
Shiliang Zhang

29 September 2025 in Engineering Structures
Verified
Journal Article
Closed access
LXLihong Xiong
Lihong Xiong
ZWZhuoxin Wang
Zhuoxin Wang

2 March 2023 in Resilient Cities and Structures
Verified
Journal Article
Open access
XYXin Yu
Xin Yu
ZWZhuoxin Wang
Zhuoxin Wang
YCYao Cui
Yao Cui
TWTianjiao Wu
Tianjiao Wu
LXLinlin Xie
Linlin Xie

8 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XWXin Wang
Xin Wang
LXLihong Xiong
Lihong Xiong
ZWZhuoxin Wang
Zhuoxin Wang
Infilled walls and frames typically employ closely spaced rigid connection, which, under seismic actions, can lead to adverse effects such as amplified seismic responses, overall torsion, and the formation of weak layers in the structure. Flexible connection isolating the infilled walls from the frames can effectively mitigate the adverse effects of rigid connections. In order to reduce the structural mass and seismic impacts, Autoclaved Aerated Concrete (AAC) masonry flexible connection infilled walls have been widely researched. However, most AAC masonry flexible connection infilled walls require complex process operations for AAC blocks, which is not conducive to practical applications in engineering. Therefore, an AAC flexible connection infilled wall with Basalt Fiber Grating (BFG) strips instead of steel bars, with simplified process operations, has been proposed. Existing finite element models for BFG strip-reinforced AAC masonry flexible connection infilled walls employ solid elements, which are difficult to apply to large-scale structural simulations; moreover, existing simplified models for flexible connection infilled walls cannot simulate out-of-plane loading. In this paper, based on homogenization methods, using simplified elements to simulate components, a simplified model for the BFG strip-reinforced AAC masonry flexible connection infilled frame is proposed. Utilizing this model, stress analyses under both in-plane and out-of-plane loading are conducted and compared with corresponding experimental results. The results indicate that the in-plane simplified model (ISM) fits well with the experimental results in terms of hysteresis curves, with similar relationships between stiffness degradation and strength attenuation. The displacement force curve of the out-of-plane simplified model (OSM) before reaching the peak load is in good agreement with the experimental results. The maximum plastic range of OSM is 5% smaller than the test results, and it can be considered that the plastic ranges of the two are comparable, manifesting the models’ capability to adequately manifest arching behavior. The simplified model enables simulation of out-of-plane loading and provides a new approach for modeling large-scale frame structures with flexible connection infilled wall.