Aquifer Thermal Energy Storage (ATES) is a promising technology for the seasonal storage of heat, thereby bridging the temporal gap between summer surpluses and peak winter demand. However, the efficiency of conventional ATES systems is severely compromised in aquifers with high groundwater flow velocities, as advective heat transport leads to significant storage losses. This study explores a novel three-well concept that implements an active hydraulic barrier, created by an additional extraction well upstream of the ATES doublet. This well effectively disrupts the regional groundwater flow, thereby creating a localized zone of stagnant or significantly reduced flow velocity, to protect the stored heat. A comprehensive parametric study was conducted using numerical simulations in FEFLOW. The experiment systematically varied three key parameters: groundwater flow velocity, the distance of the third well and its pumping rate. The performance of the system was evaluated based on its thermal recovery efficiency and a techno-economic analysis. The findings indicate that the hydraulic barrier effectively enhances heat recovery, surpassing twice the efficiency observed in a conventional two-well configuration (100 m/a). The analysis reveals a critical trade-off between hydraulic containment and thermal interference through hydraulic short-circuiting. The techno-economic assessment indicates that the three-well concept has the potential to generate significant cost and CO2e savings. These savings greatly exceed the additional capital and operational costs in comparison to a traditional doublet system in the same conditions. In conclusion, the three-well ATES system can be considered a robust technical and economic solution for expanding HT-ATES to sites with high groundwater velocities; however, its success depends on careful, model-based design to optimize these competing effects.
District heating networks (DHNs) are a key technology in the transition toward sustainable heat supply, increasingly integrating renewable sources and thermal energy storage. High-temperature aquifer thermal energy storage (HT-ATES) can enhance DHN efficiency by shifting heat production over time, potentially reducing both costs and greenhouse gas emissions. However, most life cycle assessments (LCAs) remain static, rely on average data, and neglect temporal dispatch dynamics and marginal substitution among heat sources for environmental evaluation. This study introduces a dynamic life cycle inventory framework that explicitly links HT-ATES-operation scheduling in DHNs with marginal life cycle data. The framework expands system boundaries to capture time-varying changes in heat composition, combines a district heating merit-order representation (distinguishing must-run and flexible capacities) with linear programming to determine least-cost dispatch, and translates marginally displaced technologies into environmental and economic consequences. Foreground inputs are derived from an existing third-generation DHN (heat demand, generation assets, efficiencies) and publicly available energy carrier cost data and are linked to consequential background inventory datasets (ecoinvent). The framework is demonstrated for one year of operation for an HT-ATES concept with 50 GWh of injected heat. Hourly resolved results identify the marginally displaced technologies and indicate annual reductions of 5.86 kt CO2e alongside cost savings of EUR 1.09 M. A comparison of alternative operation schedules shows strong sensitivity of both economic and environmental performance to operational strategy. Overall, the proposed framework provides a replicable and adaptable basis for consequential assessment of HT-ATES operation in DHNs and supports strategic decision-making on seasonal thermal storage deployment in low-carbon heat systems.
District heating grids (DHG) face the problem of seasonal variability and peak demands, e.g., there is a high demand for heat in winter and a low demand in summer. Operators of district heating networks and energy suppliers are therefore seeking solutions to store heat and access it at peak times, thus reducing the use of carbon-emitting heat sources. Aquifers are well suited for heat storage because of high storage capacity relative to the surface occupancy and reasonably high recovery efficiency, if geological suitable. In this study, the potential of Aquifer Thermal Energy Storages (ATES) contribution in decreasing seasonal peak heat loads is investigated by numerical modelling. Each part of the overall system (surface and subsurface) is modelled in their corresponding simulation environment. They are numerically coupled with a novel approach, allowing for highest accuracy in both subsystems. The District Heating Grid is modelled in the object-oriented modelling language Modelica including the Open-Source library MoSDH. Using the Functional Mock-Up Interface (FMI) the Modelica models are exported to executable Functional Mock-Up Units (FMU). The groundwater flow and heat transport processes are modelled in the finite-element software FEFLOW. By developing a C++ Plug-In for FEFLOW the FMU is imported and dynamically co-simulated. This approach allows for easier adjustments in both subsystems and more coupling options to existing models and softwares. Through numerical analysis different hydrological and geological scenarios of the ATES and different operational cycles are investigated to determine the long-term efficiency and capacity of the storage. This modelling approach can be used to develop strategies for the operation of the ATES as well as to evaluate in advance whether geological conditions are suitable for the particular network situation.