Fatimah AlMutawa

Dr. Fatimah AlMutawa

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Microbiology Spectrum
Verified
Journal Article
Open access
SKSang Ho Kim
Sang Ho Kim
FAFatimah AlMutawa
Fatimah AlMutawa
Cepheid’s Xpert Xpress SARS-CoV-2/Flu/RSV provides a means of rapid diagnosis that can help in hospital bed management and patient flow. It is also important for each microbiology lab to increase its capacity and most importantly have a different platform to overcome the anticipated reagent shortage at times of peak community transmission.

27 March 2022 in Case Reports in Infectious Diseases
Verified
Journal Article
Open access
PDF file
KRKassie Rong
Kassie Rong
DADelport Johan Andries
Delport Johan Andries
FAFatimah AlMutawa
Fatimah AlMutawa
Comamonas kerstersii (C. kerstersii) is a Gram-negative bacillus abundant in the environment and rarely implicated in human disease. Previously considered nonpathogenic, its scarcity in literature may be partly due to the unreliability of past phenotypic tests used for its identification. In recent years, the development of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has enabled fast and accurate laboratory identification of C. kerstersii. Since the first report of human infection in 2013, several others have emerged, with most cases involving peritoneal infection. Here, we present a rare case of C. kerstersii bacteremia in an 82-year-old male patient. With no clear predisposing conditions, the source of his infection is unclear. We accompany this report with a review of C. kerstersii bacteremia cases found in the literature.

12 August 2025 in Journal of Fungi
Verified
Journal Article
Open access
PDF file
TSTejaswini Saravanababu
Tejaswini Saravanababu
SESameer Elsayed
Sameer Elsayed
RBRuchika Bagga
Ruchika Bagga
DADelport Johan Andries
Delport Johan Andries
MSMohammadReza Rahimi Shahmirzadi
MohammadReza Rahimi Shahmirzadi
FAFatimah AlMutawa
Fatimah AlMutawa
Blastomycosis, caused by dimorphic fungi of the Blastomyces genus, is endemic to regions in North America, including the Great Lakes and other parts of Canada and the United States of America. The infection primarily occurs through the inhalation of airborne conidia from contaminated soil and decaying organic matter. Pulmonary involvement is most common, but dissemination to other organs such as the skin and bones can occur, especially in immunocompromised individuals. Diagnosis is challenging due to its clinical overlap with other diseases. Culture remains the gold-standard diagnostic method, but is time-consuming, with sensitivity ranging from 66.4% to 86%. Tissue histopathology offers quicker results but has sensitivities ranging from 36% to 85%. Antigen detection assays show high sensitivity from 76.3% to 91.3% but suffer from cross-reactivity with other fungi. PCR methods offer high specificity, with sensitivity ranging from 67.6% to 100%. In immunocompromised patients, blastomycosis is often more severe, with a mortality rate exceeding 30%. Multi-modal diagnostic approaches are crucial for accurate detection and management.

9 November 2016 in Case Reports in Infectious Diseases
Verified
Journal Article
Open access
PDF file
FAFatimah AlMutawa
Fatimah AlMutawa
DLD. Leto
D. Leto
ZCZ. Chagla
Z. Chagla
Disseminated cryptococcal infection carries a high risk of morbidity and mortality. Typical patients include HIV individuals with advanced immunosuppression or solid organ or hematopoietic transplant recipients. We report a case of disseminated cryptococcal disease in a 72-year-old male who was immunocompromised with chronic lymphocytic leukemia and ongoing chemotherapy. The patient presented with a subacute history of constitutional symptoms and headache after he received five cycles of FCR chemotherapy (fludarabine/cyclophosphamide/rituximab). Diagnosis of disseminated cryptococcal disease was made based on fungemia in peripheral blood cultures with subsequent involvement of the brain, lungs, and eyes. Treatment was started with liposomal amphotericin, flucytosine, and fluconazole as induction. He was discharged after 4 weeks of hospitalization on high dose fluconazole for consolidation for 2 months, followed by maintenance therapy.

15 June 2023 in European Journal of Microbiology and Immunology
Verified
Journal Article
Open access
PDF file
FAFatimah AlMutawa
Fatimah AlMutawa
ACAna Cabrera
Ana Cabrera
FCFeifei Chen
Feifei Chen
JDJohan Delport
Johan Delport
Background: Early identification of COVID-19 (coronavirus disease of 2019) by diagnostic tests played an important role in the isolation of infectious patients and management of this pandemic. Various methodologies and diagnostic platforms are available. The current “gold standard” for SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) diagnosis is real-time reverse transcriptase‐polymerase chain reaction (RT-PCR). To overcome the limitations posed by the short supply experienced early during the pandemic and to increase our capacity, we assessed the performance of the MassARRAY System (Agena Bioscience).Methods: MassARRAY System (Agena Bioscience) combines RT-PCR (reverse transcription-polymerase chain reaction) with high-throughput mass spectrometry processing. We compared the MassARRAY performance to a research-use-only E-gene/EAV (Equine Arteritis Virus) assay and RNA Virus Master PCR. Discordant results were tested with a laboratory-developed assay using the Corman et al. E-gene primers and probes.Results: 186 patient specimens were analyzed using the MassARRAY SARS-CoV-2 Panel. The performance characteristics were as follows: the positive agreement was 85.71%, 95% CI (78.12 – 91.45), and the negative agreement was 96.67%, 95% CI (88.47 – 99.59). 19/186 (10.2%) results were found to be discordant and assessed by a different assay with the exception of 1, where the sample was not available for repeat testing. 14 out of 18 agreed with the MassARRAY after testing with the secondary assay. The overall performance after discordance testing was as follows: the positive agreement was 97.3%, 95% CI (90.58 – 99.67), and the negative agreement was 97.14%, 95% CI (91.88 – 99.41).Conclusion: Our study demonstrates that the MassARRAY System is an accurate and sensitive method for SARS-CoV-2 detection. Following the discordant agreement with an alternate RT-PCR test, the performance was found to have sensitivity, specificity, and accuracy exceeding 97%, making it a viable diagnostic tool. It can be used as an alternative method during periods when real-time RT-PCR reagent supply chains are disrupted.

20 April 2022 in European Journal of Microbiology and Immunology
Verified
Journal Article
Open access
PDF file
KRKassie Rong
Kassie Rong
ACAna Cabrera
Ana Cabrera
DADelport Johan Andries
Delport Johan Andries
SSShannon Schofield
Shannon Schofield
FAFatimah AlMutawa
Fatimah AlMutawa
This study validated the performance of the reverse transcriptase‐polymerase chain reaction (rRT-PCR) based Cepheid Xpert® Xpress SARS-CoV-2 assay against the TIB MOLBIOL E-gene/EAV, a standard laboratory rRT-PCR SARS-CoV-2 assay. Upper and lower respiratory tract samples (nasopharyngeal and nasal swabs, bronchoalveolar lavage, and tracheal aspirate) were obtained from patients suspected to have contracted COVID-19. Results from the Xpert® Xpress and standard rRT-PCR assays were compared for positive and negative agreement and analyzed for precision, reproducibility, 95% confidence intervals, and coefficients of variation. The Xpert® Xpress assay demonstrated 100% agreement with the standard lab rRT-PCR for both upper and lower respiratory tract samples. Both the Xpert® Xpress and lab rRT-CPR identified weakly positive (Ct values 35–39) sample replicates with 100% reproducibility and showed 100% precision in identifying triplicates of upper respiratory tract samples. The single-cartridge Xpert® Xpress system has a short turnaround time and can be employed to improve patient management and hospital bed allocation. Further verification of the system is required before implementation and consideration must be paid to its higher cost and impracticality for high-throughput use.