Barış Gün Sürmeli

Dr. Barış Gün Sürmeli


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
BSBarış Gün Sürmeli
Barış Gün Sürmeli
RSRené Staritzbichler
René Staritzbichler
CRClemens Ringel
Clemens Ringel
SDSaleem Al Dakkak
Saleem Al Dakkak
HDHelene Dörksen
Helene Dörksen
Thorsten KaiserThorsten Kaiser
Thorsten Kaiser
Background: Wrong blood in tube (WBIT) is a critical pre-analytical error in laboratory medicine in which a blood sample is mislabeled with the wrong patient identity. These errors are often undetected due to the limitations of current detection strategies (e.g., delta checks). Methods: We evaluated Random Forest models for WBIT detection and conducted a detailed analyte importance analysis. In total, 799,721 samples from a German tertiary care center were analyzed and filtered for applicability. Model input features were derived by pairing consecutive same-patient samples for non-WBIT cases, simulating WBIT by pairing samples from different patients, and computing per-analyte first-order differences for each pair. We exhaustively searched all subsets of nine CBC analytes and evaluated models using F1 score, AUC, sensitivity, and PPV. Analyte importance was assessed via SHAP, permutation, and impurity decrease. Results: Models using as few as three analytes (MCV, RDW, MCH) reached F1 scores above 90%, with performance plateauing beyond six analytes. MCV and RDW were consistently top-ranked. Two-dimensional and three-dimensional visualizations revealed interpretable decision boundaries. Conclusions: Findings demonstrate that robust WBIT detection is achievable using a minimal subset of CBC analytes, offering a practical, interpretable, and broadly generalizable ML-based solution suitable for diverse clinical environments.

22 September 2023
Verified
Book Chapter
Closed access
PDF file
BSBarış Gün Sürmeli
Barış Gün Sürmeli
EGEugen Gillich
Eugen Gillich
HDHelene Dörksen
Helene Dörksen

23 November 2021 in Journal of Near Infrared Spectroscopy
Verified
Journal Article
Closed access
PDF file
BSBarış Gün Sürmeli
Barış Gün Sürmeli
IWImke Weishaupt
Imke Weishaupt
KSKnut Schwarzer
Knut Schwarzer
NMNatalia Moriz
Natalia Moriz
JSJan Schneider
Jan Schneider
Pasteurization is a crucial processing method in the food industry to ensure the safety of consumables. A major part of contemporary pasteurization processes involves using flash pasteurizer systems, where liquids are pumped through a pipe system to heat them for a predefined time. Accurately monitoring the amount of heat treatment applied to a product is challenging. This monitoring helps ensure that the correct heat impact (expressed in pasteurization units) is applied, which is commonly calculated as a product of time and temperature, taking achievability of the inactivation of the microorganisms into account. The state-of-the-art method involves a calculation of the applied pasteurization units using a one-point temperature measurement and the holding time for this temperature. Concerns about accuracy lead to high safety margins, reducing the quality of the pasteurized product. In this study, the applied pasteurization level was estimated using regression models trained with NIR spectroscopy data collected while pasteurizing fruit juices of different types and brands. Several conventional regression models were trained in combination with different preprocessing methods, including a novel prediction outlier detection method. Generalized juice models trained with the concatenated data of all types of juices demonstrated cross-validated scores of RMSECV ∼2.78 ± 0.09 and r2 0.96 ± 0.01, while separate juice models displayed averaged cross-validated scores of RMSECV ∼1.56 ± 0.04 and r2 0.98 ± 0.01. Thus, the model accuracy ±10–30 % is well within the standard safety margins.