Matthew Goupell

Dr. Matthew Goupell

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MGMatthew Goupell
Matthew Goupell
CSCorey Stoelb
Corey Stoelb
AKAlan Kan
Alan Kan
RLRuth Y. Litovsky
Ruth Y. Litovsky
Although bilateral cochlear implantation has the potential to improve sound localization and speech understanding in noise, obstacles exist in presenting maximally useful binaural information to bilateral cochlear-implant (CI) users. One obstacle is that electrode arrays may differ in cochlear position by several millimeters, thereby stimulating different neural populations. Effects of interaural frequency mismatch on binaural processing were studied in normal-hearing (NH) listeners using band-limited pulse trains, thereby avoiding confounding factors that may occur in CI users. In experiment 1, binaural image fusion was measured to capture perceptual number, location, and compactness. Subjects heard a single, compact image on 73% of the trials. In experiment 2, intracranial image location was measured for different interaural time differences (ITDs) and interaural level differences (ILDs). For larger mismatch, locations perceptually shifted towards the ear with the higher carrier frequency. In experiment 3, ITD and ILD just-noticeable differences (JNDs) were measured. JNDs increased with decreasing bandwidth and increasing mismatch, but were always measurable up to 3 mm of mismatch. If binaural-hearing mechanisms are similar between NH and CI subjects, these results may explain reduced sensitivity of ITDs and ILDs in CI users. Large mismatches may lead to distorted spatial maps and reduced binaural image fusion.

1 November 2017 in Ear & Hearing
Verified
Journal Article
Closed access
MGMatthew Goupell
Matthew Goupell
CGCasey R. Gaskins
Casey R. Gaskins
MSMaureen J. Shader
Maureen J. Shader
EWErin P. Walter
Erin P. Walter
SASamira Anderson
Samira Anderson
SGSandra Gordon-Salant
Sandra Gordon-Salant
Objectives: As people age, they experience reduced temporal processing abilities. This results in poorer ability to understand speech, particularly for degraded input signals. Cochlear implants (CIs) convey speech information via the temporal envelopes of a spectrally degraded input signal. Because there is an increasing number of older CI users, there is a need to understand how temporal processing changes with age. Therefore, the goal of this study was to quantify age-related reduction in temporal processing abilities when attempting to discriminate words based on temporal envelope information from spectrally degraded signals. Design: Younger normal-hearing (YNH) and older normal-hearing (ONH) participants were presented a continuum of speech tokens that varied in silence duration between phonemes (0 to 60 ms in 10-ms steps), and were asked to identify whether the stimulus was perceived more as the word “dish” or “ditch.” Stimuli were vocoded using tonal carriers. The number of channels (1, 2, 4, 8, 16, and unprocessed) and temporal envelope low-pass filter cutoff frequency (50 and 400 Hz) were systematically varied. Results: For the unprocessed conditions, the YNH participants perceived the word ditch for smaller silence durations than the ONH participants, indicating that aging affects temporal processing abilities. There was no difference in performance between the unprocessed and 16-channel, 400-Hz vocoded stimuli. Decreasing the number of spectral channels caused decreased ability to distinguish dish and ditch. Decreasing the envelope cutoff frequency also caused decreased ability to distinguish dish and ditch. The overall pattern of results revealed that reductions in spectral and temporal information had a relatively larger effect on the ONH participants compared with the YNH participants. Conclusions: Aging reduces the ability to utilize brief temporal cues in speech segments. Reducing spectral information—as occurs in a channel vocoder and in CI speech processing strategies—forces participants to use temporal envelope information; however, older participants are less capable of utilizing this information. These results suggest that providing as much spectral and temporal speech information as possible would benefit older CI users relatively more than younger CI users. In addition, the present findings help set expectations of clinical outcomes for speech understanding performance by adult CI users as a function of age.

1 January 2018 in Ear & Hearing
Verified
Journal Article
Closed access
MGMatthew Goupell
Matthew Goupell
OSOlga A. Stakhovskaya
Olga A. Stakhovskaya
JBJoshua G. W. Bernstein
Joshua G. W. Bernstein
Objectives: Bilateral cochlear implants (BI-CIs) are intended to improve sound localization and speech understanding in the presence of interfering sounds. For normal-hearing listeners, improved speech understanding in the presence of interfering sounds can be achieved with monaural head shadow and binaural unmasking. While some BI-CI listeners experience binaural unmasking under certain testing conditions, others appear to not. This study tested a group of BI-CI users with hearing histories that have been linked to poor binaural processing—early onset of deafness or long duration of deafness in just one ear. We predicted that these listeners would experience the opposite of binaural unmasking (i.e., contralateral interference) when trying to understand speech in the presence of a competing talker. Design: Nine adult BI-CI users who were deafened early in life or had an asymmetric hearing history (e.g., a much longer duration of deafness in one ear) participated in this study. The coordinate response measure corpus was used to assess speech understanding for a male target talker in quiet or in the presence of one male competing talker. Experiment 1 measured binaural unmasking in a paradigm that provided no head-shadow component. The target was always presented monaurally, while the interferer was presented either monaurally or diotically. Experiment 2 measured spatial release from masking in a paradigm that included both a head-shadow component and possible binaural-unmasking component. Nonindividualized head-related transfer functions were used to simulate talker locations in the front or 90° to the left or right. Results: In experiment 1, all nine listeners experienced contralateral interference (9 dB on average). Four listeners demonstrated roughly symmetric contralateral interference; five listeners experienced asymmetrical contralateral interference. In experiment 2, the listeners experienced only 1 dB of spatial release from masking on average; this small amount was possibly a result of the contralateral interference observed in experiment 1. The results were best explained by individual differences in speech understanding in quiet, which significantly correlated with the duration of deafness in the ipsilateral ear. Specifically, instances of asymmetrical contralateral interference could correspond to asymmetrical hearing histories. Conclusions: Bilateral cochlear implantation should provide a hearing benefit to the recipient. For the BI-CI listeners specifically recruited for this study, there seems to be a conflict with processing the auditory information across the two ears, which produced the opposite of the desired hearing benefit. This suggests that there may be a subset of potential BI-CI users for whom contralateral interference offsets much of the potential head-shadow benefit. If so, earlier implantation in the second implanted ear might have produced larger binaural benefits, which is important information for clinicians advising patients considering bilateral implantation.

1 September 2016 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MGMatthew Goupell
Matthew Goupell
AKAlan Kan
Alan Kan
RLRuth Y. Litovsky
Ruth Y. Litovsky
Cochlear-implant (CI) users have difficulty understanding speech in the presence of interfering sounds. This study was designed to determine if binaural unmasking of speech is limited by peripheral or central encoding. Speech was presented to bilateral CI listeners using their clinical processors; unprocessed or vocoded speech was presented to normal-hearing (NH) listeners. Performance was worst for all listener groups in conditions where both the target and interferer were presented monaurally or diotically (i.e., no spatial differences). Listeners demonstrated improved performance compared to the monaural and diotic conditions when the target and interferer were presented to opposite ears. However, only some CI listeners demonstrated improved performance if the target was in one ear and the interferer was presented diotically, and there was no change for the group on average. This is unlike the 12-dB benefit observed in the NH group when presented the CI simulation. The results suggest that CI users can direct attention to a target talker if the target and interferer are presented to opposite ears; however, larger binaural benefits are limited for more realistic listening configurations, likely due to the imprecise peripheral encoding of the two sounds.

17 January 2013 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
MGMatthew Goupell
Matthew Goupell
AKAlan Kan
Alan Kan
RLRuth Litovsky
Ruth Litovsky
Good localization accuracy depends on an auditory spatial map that provides consistent binaural information across frequency and level. This study investigated whether mapping bilateral cochlear implants (CIs) independently contributes to distorted perceptual spatial maps. In a meta-analysis, interaural level differences necessary to perceptually center sound images were calculated for 127 pitch-matched pairs of electrodes; many needed large current adjustments to be perceptually centered. In a separate experiment, lateralization was also found to be inconsistent across levels. These findings suggest that auditory spatial maps are distorted in the mapping process, which likely reduces localization accuracy and target-noise separation in bilateral CIs.

1 November 2019 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
SASean R. Anderson
Sean R. Anderson
KEKyle Easter
Kyle Easter
MGMatthew Goupell
Matthew Goupell
Bilateral cochlear implants (BICIs) provide improved sound localization and speech understanding in noise compared to unilateral CIs. However, normal-hearing (NH) listeners demonstrate superior binaural processing abilities compared to BICI listeners. This investigation sought to understand differences between NH and BICI listeners' processing of interaural time differences (ITDs) and interaural level differences (ILDs) as a function of fine-structure and envelope rate using an intracranial lateralization task. The NH listeners were presented band-limited acoustical pulse trains and sinusoidally amplitude-modulated tones using headphones, and the BICI listeners were presented single-electrode electrical pulse trains using direct stimulation. Lateralization range increased as fine-structure rate increased for ILDs in BICI listeners. Lateralization range decreased for rates above 100 Hz for fine-structure ITDs, but decreased for rates lower or higher than 100 Hz for envelope ITDs in both groups. Lateralization ranges for ITDs were smaller for BICI listeners on average. After controlling for age, older listeners showed smaller lateralization ranges and BICI listeners had a more rapid decline for ITD sensitivity at 300 pulses per second. This work suggests that age confounds comparisons between NH and BICI listeners in temporal processing tasks and that some NH-BICI binaural processing differences persist even when age differences are adequately addressed.