Tumer Erdem Guler

Tumer Erdem Guler

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2015 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
TATolga Aksu
Tolga Aksu
TGTumer Erdem Guler
Tumer Erdem Guler
ACAyse Colak
Ayse Colak
EBErkan Baysal
Erkan Baysal
MDMine Durukan
Mine Durukan
UGUmit Guray
Umit Guray
Despite the advances in medical and interventional treatment modalities, some patients develop epicardial coronary artery reperfusion but not myocardial reperfusion after primary percutaneous coronary intervention (PCI), known as no-reflow. The goal of this study was to evaluate the safety and efficacy of intracoronary epinephrine in reversing refractory no-reflow during primary PCI. A total of 248 consecutive STEMI patients who had undergone primary PCI were retrospectively evaluated. Among those, 12 patients which received intracoronary epinephrine to treat a refractory no-reflow phenomenon were evaluated. Refractory no-reflow was defined as persistent TIMI flow grade (TFG) ≤2 despite intracoronary administration of at least one other pharmacologic intervention. TFG, TIMI frame count (TFC), and TIMI myocardial perfusion grade (TMPG) were recorded before and after intracoronary epinephrine administration. A mean of 333 ± 123 mcg of intracoronary epinephrine was administered. No-reflow was successfully reversed with complete restoration of TIMI 3 flow in 9 of 12 patients (75%). TFG improved from 1.33 ± 0.49 prior to epinephrine to 2.66 ± 0.65 after the treatment (p < 0.001). There was an improvement in coronary flow of at least one TFG in 11 (93%) patients, two TFG in 5 (42%) cases. TFC decreased from 56 ± 10 at the time of no-reflow to 19 ± 11 (p < 0.001). A reduction of TMPG from 0.83 ± 0.71 to 2.58 ± 0.66 was detected after epinephrine bolus (p < 0.001). Epinephrine administration was well tolerated without serious adverse hemodynamic or chronotropic effects. Intracoronary epinephrine resulted in significant but tolerable increase in heart rate (68 ± 13 to 95 ± 16 beats/min; p < 0.001) and systolic blood pressure (94 ± 18 to 140 ± 20; p < 0.001). Hypotension associated with no-reflow developed in 5 (42%) patients. During the procedure, intra-aortic balloon pump counterpulsation was required in two (17%) patients, transvenous pacing in 2 (17%) cases, and both intra-aortic balloon counterpulsation and transvenous pacing in one (8%) patients. One patient (8%) died despite all therapeutic measures. Intracoronary epinephrine may become an effective alternative in patients suffering refractory no-reflow following primary PCI.

2 July 2024 in EP Europace
Verified
Journal Article
Open access
TATolga Aksu
Tolga Aksu
RPRoman Piotrowski
Roman Piotrowski
RTRoderick Tung
Roderick Tung
TPTom De Potter
Tom De Potter
TMTimothy M Markman
Timothy M Markman
HHHenry D. Huang
Henry D. Huang
Aims: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. Methods and results: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. Conclusion: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.

28 January 2016 in Journal of Arrhythmia
Verified
Journal Article
Open access
IEİsMail Erden
İsMail Erden
EEEmine Çakcak Erden
Emine Çakcak Erden
EGEbru Golcuk
Ebru Golcuk
TATolga Aksu
Tolga Aksu
KYKivanc YALIN
Kivanc YALIN
BTBurak Turan
Burak Turan
Background: The aim of our study was to demonstrate the added value of routine transesophageal echocardiography (TEE) for correctly positioning the transseptal system in the fossa ovalis (FO), thus potentially preventing complications during fluoroscopy‐guided transseptal puncture (TP), and for assessing the optimal puncture site within the FO according to the expected procedure type.Methods: Ninety‐one patients undergoing pulmonary vein isolation (PVI) procedures by cryoballoon technique for drug‐resistant paroxysmal or persistent atrial fibrillation (AF) were prospectively included. In 57 patients, the TP procedure was performed under fluoroscopic guidance and septal localization was confirmed by contrast injection through the needle and demonstration of septal tenting in both the anteroposterior and left lateral fluoroscopic projections. In 34 patients, TP was performed under TEE guidance and positioning was targeted to perform the TP procedure in the more anterior and inferior locations of the FO. Two patient groups were compared according to the incidence of complications directly attributable to transseptal catheterization, thromboembolic complications, recurrence rates after the ablation procedure, total procedural time, and fluoroscopy time.Results: Fluoroscopy time (p<0.001), total cryoablation time (p=0.002), and total procedural time (p<0.001) were shorter in the TEE‐guided group. Left inferior pulmonary vein (LIPV) cryoablation time (p=0.007) and right inferior pulmonary vein (RIPV) cryoablation time (p=0.004) were significantly shorter and the number of applications to the LIPV (p=0.007) and RIPV (p=0.005) were significantly fewer in the TEE‐guided group. Although there was a trend toward higher complication rates (20.6% vs. 31.6%, p=0.37) and recurrence rates (11.8% vs. 20.1%, p=0.26) in the fluoroscopy‐guided group, the differences between the groups were not statistically significant.Conclusions: TEE‐guided TP for AF ablation is associated with shorter fluoroscopy time, shorter total cryoablation time, and shorter total procedural time. Importantly, TEE‐guided TP facilitates cryoablation of the inferior pulmonary veins.

27 February 2022 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
EBErkan Baysal
Erkan Baysal
MOMetin Okşul
Metin Okşul
CBCengiz Burak
Cengiz Burak
KYKivanc YALIN
Kivanc YALIN
ASAli Ugur Soysal
Ali Ugur Soysal
TATolga Aksu
Tolga Aksu

1 March 2020 in e-Journal of Cardiovascular Medicine
Verified
Journal Article
Closed access
TGTumer Erdem Guler
Tumer Erdem Guler
TATolga Aksu
Tolga Aksu

24 July 2024 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
ŞÖŞükriye Ebru Önder
Şükriye Ebru Önder
TGTumer Erdem Guler
Tumer Erdem Guler
SBSerdar Bozyel
Serdar Bozyel
NDNur Dalgıç
Nur Dalgıç
AŞAbdülcebbar Şipal
Abdülcebbar Şipal
TATolga Aksu
Tolga Aksu