Martina Schmid-Schwap

Prof. Dr. Martina Schmid-Schwap

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of Orofacial Pain
Verified
Journal Article
Closed access
MSMartina Schmid-Schwap
Martina Schmid-Schwap
MBMargit Bristela
Margit Bristela
MKMichael Kundi
Michael Kundi
EPEva Piehslinger
Eva Piehslinger
To explore potential differences in characteristics of patients that might account for sex-specific differences in temporomandibular disorders (TMD). A total of 502 patients presenting with TMD during 2000 to 2002 at the Outpatient Unit for Functional Disorders of the Medical University of Vienna underwent detailed evaluation of their medical history and assessment of clinical findings. The data obtained were assessed for sex-specific differences by analysis of variance and multiple regression. Overall, 404 females (mean age ± SD: 40 ± 16 years; range 12 to 96 years) and 98 males (mean age 41 ± 16 years; range 16 to 78 years) were included. Their rating of their pain on a visual analog scale (VAS) showed a significantly higher pain intensity for females than for males (P = .004). Clinical assessment showed a significantly lower degree of mouth opening for females than for males (P < .001). While no sex-specific differences were noted for clicking phenomena of the temporomandibular joint (TMJ) and for the bite class of the patients, bite anomalies were significantly more frequent in male patients (P = .03). Palpation of masticatory muscles and the TMJ revealed significantly higher tenderness on palpation in female as compared to male patients (P = .001). Grouping by clicking, crepitation, and bruxism also showed greater pain (VAS) and more tenderness on palpation in females versus males. Females also showed peaks of prevalence of TMD in the age group below 25 years and in the group 55 to 60 years, whereas males had a more even age distribution. No external factors, such as exposure to stress, were found that moderated the sex difference. Female TMD patients showed greater pain and muscle tenderness on palpation as compared to male TMD patients. They also showed a different age distribution of prevalence of TMD. These results were independent of subjective symptoms, clinical findings, and external factors.

1 March 2009 in Dental Materials
Verified
Journal Article
Closed access
MSMartina Schmid-Schwap
Martina Schmid-Schwap
AFAlexander Franz
Alexander Franz
FKFranz König
Franz König
MBMargit Bristela
Margit Bristela
TLTrevor Lucas
Trevor Lucas
ASAndreas Schedle
Andreas Schedle

5 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LCLana Zupancic Cepic
Lana Zupancic Cepic
RGReinhard Gruber
Reinhard Gruber
JEJaryna Eder
Jaryna Eder
TVTom Vaskovich
Tom Vaskovich
MSMartina Schmid-Schwap
Martina Schmid-Schwap
Michael KundiMichael Kundi
Michael Kundi
Digital technology facilitates the manufacturing of complete dentures; however, clinical and patient-reported outcomes are underreported. This prospective, randomized, single-blind cross-over study reports the clinical and patient-related outcomes of 10 edentulous patients receiving digital dentures prepared with the Vita Vionic System and conventional dentures produced from heat-polymerized polymethylmethacrylate resin. Clinical efficiency was stated based on the Sato score for quantitative assessment of complete denture quality. Patient satisfaction was evaluated with the oral health-related quality of life questionnaire (OHIP-20). We report here that the Sato score was slightly higher in patients receiving digital versus conventional dentures with a mean of 73.2 ± 12.3 and 67.4 ± 11.8, respectively (p = 0.16). Moreover, upper and lower stability was superior in digital dentures (p = 0.03 and p = 0.10, respectively), while denture polish was better in conventional dentures (p = 0.03). Quality of life was slightly higher in patients receiving conventional compared to digital dentures with an OHIP-20 of 101.7 ± 12.0 and 95.6 ± 24.2, respectively (p = 0.33). Taken together and when considering the low power of the study, our findings suggest a trend towards better clinical efficiency of digital compared to conventional dentures, while patient satisfaction remained unaffected by the type of manufacturing.

1 September 2011 in Dental Materials
Verified
Journal Article
Closed access
MSMartina Schmid-Schwap
Martina Schmid-Schwap
AGAlexandra Graf
Alexandra Graf
APAngela Preinerstorfer
Angela Preinerstorfer
DWDavid Christopher Watts
David Christopher Watts
EPEva Piehslinger
Eva Piehslinger
ASAndreas Schedle
Andreas Schedle

1 February 1998 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
BGB Gsellmann
B Gsellmann
MSMartina Schmid-Schwap
Martina Schmid-Schwap
EPE Piehslinger
E Piehslinger
RSR Slavicek
R Slavicek

1 August 2009 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MSMartina Schmid-Schwap
Martina Schmid-Schwap
VRValentin Rousson
Valentin Rousson
KVKarin Vornwagner
Karin Vornwagner
SHSiegward D. Heintze
Siegward D. Heintze