The correlation between the MLC QA (IBA Dosimetry, Germany) results of the picket fence test created with intentional errors and the patient's quality assurance (QA) evaluation was investigated to assess the impact of multileaf collimator (MLC) positioning error on patient QA. The picket fence, including error-free and intentional MLC errors, defined in Bank In, Bank Out, and Bank Both were analyzed using MLC QA. The QA of 15 plans consisting of stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), and conventionally fractionated volumetric-modulated arc therapy (VMAT) acquired with electronic portal imaging devices (EPID) was evaluated in the presence of error-free and MLC errors. The QA of plans were analyzed with 2%/2 mm and 3%/3 mm criteria. The passing rates of the picket fence test were 97%, 92%, 91%, and 87% for error-free and intentional errors. The criterion of 3%/3 mm wasn’t able to detect an MLC error for either SRS/SBRT or conventionally fractionated VMAT. The criterion of 2%/2mm was more sensitive to detect MLC error for the conventionally fractionated VMAT than SRS/SBRT. While only two of SBRT plans had <90%, four of conventionally fractionated VMAT plans had a <90% passing rate. We found that the systematic MLC positioning errors defined with picket fence have a smaller but measurable impact on SRS/SBRT than the VMAT plan for a conventionally fractionated and relatively complex plan such as head and neck and endometrium cases.
Objectives: To investigate diffusional changes in multiple sclerosis (MS) plaques and non-Gaussian behavior of water diffusion by using diffusional kurtosis imaging (DKI). Methods: 31 MS patients and 21 controls underwent MRI on a 3T scanner. Mean kurtosis (MK) parametric maps were computed. Region of interest (ROI) was delineated as white matter (WM) in controls and MS plaques and WM in patients. Results: There was no significance of WM kurtosis and skewness parameters among MS group and control group patients p=0.213 and p=0.390, respectively. In MS patients, kurtosis, skewness, maximum intensity, minimum intensity, and median intensity values of WM, Plaque 1, Plaque 2, and Plague 3 were significantly higher at p<0.0001 for all. Conclusions: DKI may provide more extensive characterization of lesions and WM and may be a sensitive indicator of tissue damage and microstructural change in patients with MS in addition to conventional diffusional evaluations.
Background/Objectives: Breast ultrasound is widely used for the diagnostic evaluation of breast lesions; however, reliable lesion characterization remains challenging due to substantial image heterogeneity and the limited size of most clinically available datasets. These constraints reduce the generalizability of end-to-end deep learning approaches in routine practice. The objective of this study was to evaluate a data-efficient diagnostic framework that integrates image-derived features with clinical sonographic descriptors to improve breast ultrasound lesion classification in small cohorts. Methods: Ultrasound images from the publicly available BrEaST-Lesions dataset were processed using a pretrained convolutional neural network to extract compact image feature representations from full images, lesion masks, and cropped tumor regions. These features were combined with manually recorded sonographic descriptors after label encoding to form a unified tabular dataset. Gradient-boosted tree models were trained using descriptor-only and fused feature sets with fivefold stratified cross-validation and evaluated on an independent external hold-out test set. Results: Using sonographic descriptors alone, the best-performing model (LightGBM) achieved an external validation accuracy of 0.88, with an area under the receiver operating characteristic curve (AUC) of 0.95. Incorporation of image-derived features improved diagnostic performance on the external test set, yielding an accuracy of 0.88, an AUC of 0.96, and a sensitivity of 1.00 for malignant lesion detection. The fused framework demonstrated more stable generalization than descriptor-only models, particularly for malignant cases. Conclusions: Combining image-derived features with clinical sonographic descriptors within a tabular learning framework provides a robust and data-efficient approach for breast ultrasound-based lesion classification. This strategy supports diagnostic decision-making in small ultrasound datasets and represents a clinically realistic alternative when large-scale deep learning models are impractical.
Multipl Skleroz (MS), vücudun bağışıklık sistemi hücreleri tarafından beyindeki sinir hücrelerinin dış kısmında bulunan miyelin kılıfların zarar görmesi sonucu lezyon veya plak oluşmasına bağlı nörolojik bir hastalıktır. Bu makalenin amacı Sekonder Progresif MS (SPMS) için tıp ve biyomedikal mühendisliği alanında çözüm önerileri üreterek yapılan çalışmaların anlatılmasıdır. Hastalığın tıp alanında çeşitli tedavi yöntemleri vardır. MS tedavisi kişiye özel olarak yapılmaktadır. Tıp alanında yapılan en temel tedavi yöntemi ilaç ile tedavidir. Son yapılan çalışmalar sonucunda nanoparçacıkların polimerik yapısının içerisine konulan miyelin antijenleri sayesinde bağışıklık sistemi hücrelerinin miyelinli hücrelere saldırması engellenerek hastalığın yavaşlatılması sağlanmıştır. Zarar gören miyelin kılıfların onarımı ise kolesterolün düşürülmesinde kullanılan bir molekül sayesinde yapılmıştır. MS tam olarak nedeni bilinmeyen otoimmün ve nörolojik bir hastalıktır. Bu makale çalışmasında ise yapılmış olan deneysel çalışmalara göre üretilen tüm çözüm önerilerinin derlenmesi amaçlanmıştır.