This study investigates the stability of multiple three‐phase converters connected to weak grids. It has been derived a flexible modelling regarding the number of converter and type of collector system. The both eigenvalues and impedance based methods are applied to the stability analysis. The eigenvalues method is used to give guidelines on the choice of the phase‐looked loop (PLL) gains. To improve the stability margins, the increase in the PLL damping ratio is proposed. Moreover, it is used to investigate the PLL interaction with converter current and DC bus voltage controllers. The impedance based method extends the stability analysis to multiple three‐phase converters. In addition, it has been used to show the effects of converter current and DC bus voltage controllers parameters on the stability margins. Finally, in order to validate the theoretical analysis, time‐domain results with hardware‐in‐the‐loop are given, showing a strong correlation with the theoretical analysis in the frequency domain.
8 December 2025 in Sustainable Energy Technologies and Assessments
This paper presents a new method of carried-based discontinuous geometric modulation approach for three-phase voltage fed converters with multiple magnetically coupled legs. The proposed modulation technique produces multilevel equivalent PWM line-to-line output voltages with a reduced harmonic distortion, allows circulating current control and distributes equally the commutation between the switches an keeping a low number of commutations. For that, a state machine is used to achieve the results. Moreover, it is important to mention that the implementation of the proposed modulation is straightforward, requiring neither a complex hardware nor a high development effort. Furthermore, simulation and experimental results are presented to demonstrate the good performance of the proposed method for two magnetically coupled legs.
This study proposes a SCADA-based framework for wind turbine degradation analysis using complementary performance indicators, explicitly accounting for wind speed measurement quality. A systematic validation procedure based on redundant nacelle sensors is introduced to ensure the reliability of wind speed data, highlighting the potential impact of measurement inconsistencies on degradation assessment. The methodology combines power and operation curve-based indicators, enabling, for the first time, a direct comparison between these two approaches. The results show that the power curve based indicator is more sensitive to wind speed measurement errors, while the operation indicator better captures variations in the turbine operating point, although it may also be indirectly affected depending on the control strategy. The framework is applied to multi-year SCADA data from a wind farm, including periods with changes in Region 2 control strategies related to yaw control and maximum power point tracking, revealing a slight degradation trend at the fleet level and significant variability among individual turbines. Overall, the results demonstrate that degradation assessment is strongly dependent on wind measurement quality and that combining complementary indicators provides a more robust and physically consistent interpretation of wind turbine performance over time.