Naritsaret Kaewboonlert

Dr. Naritsaret Kaewboonlert

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2025 in JMIR Medical Education
Verified
Journal Article
Open access
NKNaritsaret Kaewboonlert
Naritsaret Kaewboonlert
JPJiraphon Poontananggul
Jiraphon Poontananggul
NPNatthipong Pongsuwan
Natthipong Pongsuwan
GBGun Bhakdisongkhram
Gun Bhakdisongkhram
Background: Artificial intelligence (AI) has become widely applied across many fields, including medical education. Content validation and its answers are based on training datasets and the optimization of each model. The accuracy of large language model (LLMs) in basic medical examinations and factors related to their accuracy have also been explored. Objective: We evaluated factors associated with the accuracy of LLMs (GPT-3.5, GPT-4, Google Bard, and Microsoft Bing) in answering multiple-choice questions from basic medical science examinations. Methods: We used questions that were closely aligned with the content and topic distribution of Thailand’s Step 1 National Medical Licensing Examination. Variables such as the difficulty index, discrimination index, and question characteristics were collected. These questions were then simultaneously input into ChatGPT (with GPT-3.5 and GPT-4), Microsoft Bing, and Google Bard, and their responses were recorded. The accuracy of these LLMs and the associated factors were analyzed using multivariable logistic regression. This analysis aimed to assess the effect of various factors on model accuracy, with results reported as odds ratios (ORs). Results: The study revealed that GPT-4 was the top-performing model, with an overall accuracy of 89.07% (95% CI 84.76%‐92.41%), significantly outperforming the others (P<.001). Microsoft Bing followed with an accuracy of 83.69% (95% CI 78.85%‐87.80%), GPT-3.5 at 67.02% (95% CI 61.20%‐72.48%), and Google Bard at 63.83% (95% CI 57.92%‐69.44%). The multivariable logistic regression analysis showed a correlation between question difficulty and model performance, with GPT-4 demonstrating the strongest association. Interestingly, no significant correlation was found between model accuracy and question length, negative wording, clinical scenarios, or the discrimination index for most models, except for Google Bard, which showed varying correlations. Conclusions: The GPT-4 and Microsoft Bing models demonstrated equal and superior accuracy compared to GPT-3.5 and Google Bard in the domain of basic medical science. The accuracy of these models was significantly influenced by the item’s difficulty index, indicating that the LLMs are more accurate when answering easier questions. This suggests that the more accurate models, such as GPT-4 and Bing, can be valuable tools for understanding and learning basic medical science concepts.

2 May 2024 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
PDF file
NKNaritsaret Kaewboonlert
Naritsaret Kaewboonlert
PCPiyapat Chunharas
Piyapat Chunharas
NPNaree Pluthikarmpae
Naree Pluthikarmpae
JPJiraphon Poontananggul
Jiraphon Poontananggul
AWAkharawat Wongthep
Akharawat Wongthep
ULUdomsak Lerssuttipon
Udomsak Lerssuttipon
Ventricular hemangiomas are rare benign tumors, pose diagnostic and therapeutic complexities. We report a case of a 52-year-old female with essential hypertension who developed a systolic ejection murmur during a hypertension clinic visit. The echocardiogram revealed a hyperechoic mass obstructing the right ventricular outflow tract, causing enlargement of the right atrium and ventricle, with a reduction in the right ventricular ejection fraction. Due to the risk of death, the patient underwent an emergency surgical resection along with tricuspid valve replacement. Postoperative recovery was uneventful, and subsequent cardiac magnetic resonance imaging showed an improvement in ejection fraction without residual tumor. This case highlights the diagnosis and therapeutic complexities of ventricular hemangiomas. With this report, we aim to provide a comprehensive review of ventricular hemangiomas and to enhance understanding of this condition for improved patient care.

4 September 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NKNaritsaret Kaewboonlert
Naritsaret Kaewboonlert
WSWorawong Slisatkorn
Worawong Slisatkorn
Apichat TantraworasinApichat Tantraworasin
Apichat Tantraworasin
PPPunthiti Pleehachinda
Punthiti Pleehachinda
TPTossapol Prapassaro
Tossapol Prapassaro
TRTummarat Ruangpratyakul
Tummarat Ruangpratyakul
Objectives: To systematically review propensity score-matched studies comparing hybrid arch repair (HAR) with total arch replacement (TAR) for aortic arch pathologies, summarizing early outcomes and intermediate-term results. Methods: We searched PubMed, Embase, the Cochrane Library, and Google Scholar to April 2024. The primary outcome was in-hospital mortality, evaluated by a random-effects model to calculate the odds ratio (OR). Time-to-event outcomes were synthesized as hazard ratios (HR) using inverse variance method. Results: Eight studies comprising 860 patients were included. There was no significant difference in in-hospital mortality between HAR and TAR groups (OR 0.66; 95% CI 0.33–1.31; p = 0.240). HAR was associated with a lower incidence of renal failure (OR 0.51; 95% CI 0.30–0.88; p = 0.020). In the isolated type A aortic dissection (ITAAD) subgroup, HAR showed a non-significant trend toward lower in-hospital mortality (OR 0.66; 95% CI 0.33–1.31, p = 0.24). In mixed degeneration-dissection (MDAD), TAR showed a non-significant trend toward lower risk of permanent neurological dysfunction (PND) (OR 2.84; 95% CI 0.89–9.10; p = 0.080) and a significantly lower three-year re-interventions rate (HR 2.99; 95% CI 1.48–6.04; p < 0.001). Other postoperative complications did not differ significantly: sternal re-entry for hemorrhage (OR 0.55; 95% CI 0.21–1.43; p = 0.220), and tracheostomy (OR 1.08; 95% CI 0.43–2.72; p = 0.870). Conclusions: HAR was associated with a lower risk of renal failure. In ITAAD, HAR showed a trend toward lower in-hospital mortality, whereas in MDAD cohorts, TAR showed a significantly lower three-year re-intervention rate. These findings should be interpreted with caution given the small number of studies and underlying heterogeneity. Further observational studies or randomized trials are warranted.

14 November 2025 in Asian Cardiovascular and Thoracic Annals
Verified
Journal Article
Closed access
NKNaritsaret Kaewboonlert
Naritsaret Kaewboonlert
NPNatthipong Pongsuwan
Natthipong Pongsuwan
CCChanut Chatkaewpaisal
Chanut Chatkaewpaisal
JPJiraphon Poontananggul
Jiraphon Poontananggul
Introduction: The optimal extent of aortic arch intervention for acute type A aortic dissection (ATAAD) remains uncertain. Total arch replacement with a frozen elephant trunk (TAR + FET) prolongs circulatory-arrest time, whereas hybrid arch repair (HAR)—supra-aortic debranching in combination with antegrade endovascular stent grafting—reduces ischemic time but may increase the risk of late reintervention. Objective: This study aims to compare mid-term survival and freedom from reintervention after HAR versus TAR in ATAAD. Methods: PubMed, Embase, and Scopus were searched from their inception to May 2025. Kaplan–Meier Curves were digitized, and individual-participant data were reconstructed with a validated algorithm. Pooled hazard ratios (HR) were derived from a one-stage flexible parametric model; robustness was assessed with two-stage random-effects meta-analysis, leave-one-out tests. Results: Five propensity-matched studies ( n = 697; 338 HAR, 359 TAR) met inclusion criteria. Hybrid arch repair shortened cardiopulmonary bypass and avoided circulatory arrest time. Five-year survival was 86.5% for HAR versus 76.2% for TAR (log-rank p < 0.001). Hybrid arch repair provided a significant early-to-mid-term survival advantage over TAR in ATAAD (HR 0.46 (95% CI 0.31–0.69; p < 0.001)), corresponding to about 6 months of survival benefit at 5 years. Hybrid arch repair was associated with greater likelihood of early reintervention (HR 4.07, 95% CI 0.55–30.34). Conclusion: Hybrid arch repair offers a significant early-to-mid-term survival advantage over TAR in ATAAD. In patients requiring aortic arch replacement, HAR may be favored over TAR/FET, while extensive TAR/FET procedures are reserved for anatomically unsuitable cases.


12 November 2024 in medRxiv
Verified
Preprint
Open access
PDF file
NKNaritsaret Kaewboonlert
Naritsaret Kaewboonlert
WSWorawong Slisatkorn
Worawong Slisatkorn
Apichat TantraworasinApichat Tantraworasin
Apichat Tantraworasin
PPPunthiti Pleehachinda
Punthiti Pleehachinda
TPTossapol Prapassaro
Tossapol Prapassaro
TRTummarat Ruangpratyakul
Tummarat Ruangpratyakul
OBJECTIVES: To systematically review and pool the clinical outcomes of hybrid arch repair (HAR) and total arch replacement (TAR) with or without a frozen elephant trunk for treating aortic arch aneurysms, dissections, or other pathology in propensity score-matched studies. METHODS: We conducted electronic database searches in PubMed, Embase, the Cochrane Library, and Google Scholar to identify studies reporting outcomes of HAR versus TAR. Risk of bias was assessed using non-randomized studies of interventions (ROBINS-I) tool. The primary outcome was in-hospital mortality analyzed using a random-effects model to compute the odds ratio (OR). Survival probability was expressed as hazard ratios (HR) calculated through the inverse variance method. The results were reported following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. RESULTS: This meta-analysis included 13 studies with 3,392 patients. There was no significant difference in in-hospital mortality between HAR and TAR groups (OR 1.08; 95% CI 0.78-1.49; p = 0.630). However, HAR group showed a higher incidence of permanent neurological dysfunction (PND) (OR 1.71; 95% CI 1.22-2.41; p < 0.001). In subgroup meta-analysis with isolated type A aortic dissection (ITAAD), HAR showed significantly lower in-hospital mortality (p = 0.040) but no difference in PND. Other post-operative complications were significantly lower in the HAR group for renal failure (OR 0.65; 95% CI 0.49-0.87; p < 0.001), sternal re-entry due to bleeding (OR 0.55; 95% CI 0.34-0.89; p = 0.010), and tracheostomy (OR 0.61; 95% CI 0.38-0.96; p = 0.030). There is no statistical difference in 3-year survival probability (HR 0.97; 95% CI 0.70-1.35; p = 0.870). CONCLUSIONS: TAR has more favorable than HAR in MDAD patients, offering lower rates of neurological dysfunction and better 3-year freedom from re-intervention. For ITAAD patients, HAR potentially provides better in-hospital mortality and 3-year survival rates, with fewer complications such as renal failure, re-sternotomy, and tracheostomy.