David Völgyes

David Völgyes


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in European Journal of Radiology Open
Verified
Journal Article
Open access
HAHilde Kjernlie Andersen
Hilde Kjernlie Andersen
DVDavid Völgyes
David Völgyes
AMAnne Catrine Trægde Martinsen
Anne Catrine Trægde Martinsen
Iterative reconstruction techniques for reducing radiation dose and improving image quality in CT have proved to work differently for different patient sizes, dose levels, and anatomical areas. This study aims to compare image quality in CT of the lungs between four high-end CT scanners using the recommended reconstruction techniques at different dose levels and patient sizes. A lung phantom and an image quality phantom were scanned with four high-end scanners at fixed dose levels. Images were reconstructed with and without iterative reconstruction. Contrast-to-noise ratio, modulation transfer function, and peak frequency of the noise power spectrum were measured. IMR1 Sharp+ and VEO improved contrast-to-noise ratio to a larger extent than the other iterative techniques, while maintaining spatial resolution. IMR1 Sharp+ also maintained noise texture. IMR1 Sharp+ was the only reconstruction technique in this study which increased CNR to a large extent, while maintaining all other image quality parameters measured in this study.

1 January 2017 in Journal of Computer Assisted Tomography
Verified
Journal Article
Open access
DVDavid Völgyes
David Völgyes
MPMarius Pedersen
Marius Pedersen
ASArne Stray-Pedersen
Arne Stray-Pedersen
DWDag Waaler
Dag Waaler
AMAnne Catrine Trægde Martinsen
Anne Catrine Trægde Martinsen
The aim of this study was to evaluate how different iterative and filtered back projection kernels affect the computed tomography (CT) numbers and low contrast detectability. Five different scans were performed at 6 different tube potentials on the same Catphan 600 phantom using approximately the same dose level and otherwise identical settings. The scans were reconstructed using all available filtered back projection body kernels and with iterative reconstruction techniques. The CT numbers and the contrast-to-noise ratios were reported and how they are affected by the kernel choice and strength of iterative reconstruction. Iterative reconstruction improved contrast-to-noise ratio in most cases, but in certain situations, it decreased it. Variations in CT numbers can be large between kernels with similar sharpness for certain densities.

27 April 2016 in Open Medicine Journal
Verified
Journal Article
Open access
PDF file
MPMalgorzata Z. Pajak
Malgorzata Z. Pajak
DVDavid Völgyes
David Völgyes
SPSally L. Pimlott
Sally L. Pimlott
CSCarlos C. Salvador
Carlos C. Salvador
AAAntonio S. Asensi
Antonio S. Asensi
KAKurt I. Anderson
Kurt I. Anderson
Goals:This paper presents the performance review based on a dual-ring Positron Emission Tomography (PET) scanner being a part of Bruker Albira: a multi-modal small-animal imaging platform. Each ring of Albira PET contains eight detectors arranged as octagon, and each detector is built using a single continuous lutetium-yttrium oxyorthosilicate crystal and multi-anode photo multiplier tube. In two-ring configuration, the scanner covers 94.4 mm in axial- and 80´80 mm in trans-axial direction, which is sufficient to acquire images of small animals (e.g.mice) without the need of moving the animal bed during the scan.Methods:All measurements and majority of data processing were performed according to the NEMA NU4-2008 standard with one exception. Due to the scanner geometry, the spatial resolution test was reconstructed using iterative algorithm instead of the analytical one. The main performance characteristics were compared with those of the other PET sub-systems of tri-modal small-animal scanners.Results:The measured spatial resolution at the centre of the axial field of view in radial, tangential and axial directions was 1.72, 1.70 and 2.45 mm, respectively. The scatter fraction for the mouse-like phantom was 9.8% and for the rat-like phantom, 21.8%. The maximum absolute sensitivity was 5.30%. Finally, the recovery co-efficients for 5, 4, 3, 2, 1 mm diameter rods in image quality phantom were: 0.90, 0.77, 0.66, 0.30 and 0.05, respectively.Conclusion:The Bruker Albira is a versatile small-animal multi-modal device that can be used for variety of studies. Overall the PET sub-system provides a good spatial resolution coupled with better-than average sensitivity and the ability to produce good quality animal images when administering low activities.

1 October 2011
Verified
Conference Paper
Closed access
MMMilan Magdics
Milan Magdics
LSLászló Szirmay-Kalos
László Szirmay-Kalos
BTBalazs Toth
Balazs Toth
DLDavid Legrady
David Legrady
ACAron Cserkaszky
Aron Cserkaszky
TBTamas Bukki
Tamas Bukki
In positron emission tomography (PET), photon scattering inside the body causes significant blurring and quantification error in the reconstructed images. To solve this problem we have developed Monte Carlo (MC) based 3D PET reconstruction algorithms implemented on the Graphics Processing Unit (GPU). Our implementation takes multiple Compton scattering into account without any significant additional cost. The performance of the scatter correction is evaluated using GATE simulation as well as by comparing reconstruction results of Tera-Tomo to the reference reconstruction implementation of the Philips Gemini TOF PET which applies attenuation correction and single scatter simulation (SSS) for scatter correction. The comparative reconstruction results are based on the NEMA NU2-2007 image quality phantom.

10 May 2022 in IEEE Access
Verified
Journal Article
Open access
BABorge Solli Andreassen
Borge Solli Andreassen
DVDavid Völgyes
David Völgyes
ESEigil Samset
Eigil Samset
ASAnne H. Schistad Solberg
Anne H. Schistad Solberg
Segmentation of the mitral annulus is often an important step in cardiac examinations. We propose a robust 3D method for predicting the anatomical orientation and segmentation of the mitral annulus in 3D transesophageal echocardiography. The method takes advantage of the circular anatomy of the annulus by utilizing cylinder coordinate samples and a 3D convolutional neural network with circular convolutions. Furthermore, the paper proposes new landmark detection loss functions based on the earth mover’s distance. The method’s effectiveness was demonstrated by training a HighRes3dNet model and evaluating its performance on a separate test set consisting of 135 frames from 19 examinations. The obtained coordinate prediction error was 1.96±1.62 mm, and the anatomical orientation prediction error was 9.7°±15.8°. The robust and fully automatic mitral annulus segmentation and orientation prediction provided by the method can ease the workload of clinicians and provide time savings in clinics.

25 July 2018 in Algorithms
Verified
Journal Article
Open access
PDF file
DVDavid Völgyes
David Völgyes
AMAnne Catrine Trægde Martinsen
Anne Catrine Trægde Martinsen
ASArne Stray-Pedersen
Arne Stray-Pedersen
DWDag Waaler
Dag Waaler
MPMarius Pedersen
Marius Pedersen
Computed Tomography (CT) images have a high dynamic range, which makes visualization challenging. Histogram equalization methods either use spatially invariant weights or limited kernel size due to the complexity of pairwise contribution calculation. We present a weighted histogram equalization-based tone mapping algorithm which utilizes Fast Fourier Transform for distance-dependent contribution calculation and distance-based weights. The weights follow power-law without distance-based cut-off. The resulting images have good local contrast without noticeable artefacts. The results are compared to eight popular tone mapping operators.