Purpose: This study aimed to investigate the dosimetric impact of deep‐learning‐based auto‐contouring for clinical target volume (CTV) and organs at risk (OARs) delineation in prostate cancer radiotherapy planning. Additionally, we compared the geometric accuracy of auto‐contouring system to the variability observed between human experts.Methods: We evaluated 28 planning CT volumes, each with three contour sets: reference original contours (OC), auto‐segmented contours (AC), and expert‐defined manual contours (EC). We generated 3D‐CRT and intensity‐modulated radiation therapy (IMRT) plans for each contour set and compared their dosimetric characteristics using dose‐volume histograms (DVHs), homogeneity index (HI), conformity index (CI), and gamma pass rate (3%/3 mm).Results: The geometric differences between automated contours and both their original manual reference contours and a second set of manually generated contours are smaller than the differences between two manually contoured sets for bladder, right femoral head (RFH), and left femoral head (LFH) structures. Furthermore, dose distribution accuracy using planning target volumes (PTVs) derived from automatically contoured CTVs and auto‐contoured OARs demonstrated consistency with plans based on reference contours across all evaluated cases for both 3D‐CRT and IMRT plans. For example, in IMRT plans, the average D95 for PTVs was 77.71 ± 0.53 Gy for EC plans, 77.58 ± 0.69 Gy for OC plans, and 77.62 ± 0.38 Gy for AC plans. Automated contouring significantly reduced contouring time, averaging 0.53 ± 0.08 min compared to 24.9 ± 4.5 min for manual delineation.Conclusion: Our automated contouring system can reduce inter‐expert variability and achieve dosimetric accuracy comparable to gold standard reference contours, highlighting its potential for streamlining clinical workflows. The quantitative analysis revealed no consistent trend of increasing or decreasing PTVs derived from automatically contoured CTVs and OAR doses due to automated contours, indicating minimal impact on treatment outcomes. These findings support the clinical feasibility of utilizing our deep‐learning‐based auto‐contouring model for prostate cancer radiotherapy planning.
Background: Deep inspiration breath-hold (DIBH) is known as a radiotherapy method for thetreatment of patients with left-sided breast cancer. In this method, patient is under exposureonly while he/she is at the end of a deep inspiration cycle and holds his/her breath. In thissituation, the volume of the lung tissue is enhanced and the heart tissue is pushed away from thetreating breast. Therefore, heart dose of these patients, using DIBH, experiences a considerable decline compared to free breathing treatment. There are a few commercialized systems forimplementation of DIBH in invasive or noninvasive manners. Methods: We present a novelconstructed noninvasive DIBH device relied on a manufacturing near-field laser distance meter.This in-house constructed system is composed of a CD22-100AM122 laser sensor combined with a data acquisition system for monitoring the breathing curve. Qt Creator (a cross-platform JavaScript, QML, and C++-integrated development environment that is part of the SDK fordevelopment of the Qt Graphical User Interface application framework) and Keil MDK-ARM (aprogramming software where users can write in C and C++ and assemble for ARM-based microcontrollers) are used for composing computer and microcontroller programs, respectively. Results: This system could be mounted in treatment or computed tomography (CT) roomat suitable cost; it is also easy to use and needs a little training for personnel and patients.The system can assess the location of chest wall or abdomen in real time with high precisionand frequency. The performance of CD22-100AM122 demonstrates promise for respiratorymonitoring for its fast sampling rate as well as high precision. It can also deliver reasonablespatial and temporal accuracy. The patient observes his/her breathing waveform through a 7"1024 * 600 liquid crystal display and gets some instructions during treatment and CT sessionsby an exploited algorithm called "interaction scenario" in this study. The system is alsononinvasive and well sustainable for patients. Conclusions: The constructed system has true real-time operation and is rapid enough for delivering clear contiguous monitoring. In addition,in this system, we have provided an interaction scenario option between patient and CT or Linacoperator. In addition, the constructed system has the capability of sending triggers for turningon and off CT or Linac facilities. In this concern, the system has the superiority of combining aplenty of characteristics.
10 September 2019 in Journal of Radiotherapy in Practice
Introduction and purpose:The error in set-up of patients is an inherent part of treatment processes. The positioning errors can be used to determine the margins of the planning target volume (PTV) to cover the target volume, while minimising the radiation dose delivered to normal tissues. This study aimed to evaluate random and systematic errors occurring in inter-fraction set-ups of pelvic radiotherapy measured by electronic portal imaging device (EPID) and then to propose the optimum clinical target volume (CTV) to PTV margin in pelvic cancer patients.Materials and methods:This study examined 22 patients treated with pelvic radiotherapy. A total of 182 portal images were evaluated. Population random (σ) and systematic (Σ) errors were determined based on the portal images in three directions (X, Y and Z). The set-up margin for CTV to PTV was calculated by published margin formulae of International Commission on Radiation Units and measurements (ICRU) report No. 62 recommendation and formulas presented by Stroom and Heijmen and Van Herk et al.Results:Systematic set-up errors for radiotherapy to patients ranged between 2·36 and 4·99 mm, and random errors ranged between 1·51 and 2·74 mm. The margin required to cover the target volume retrospectively was calculated based on ICRU 62 and formulas presented by Stroom and Heijmen and Van Herk et al. were used to calculate the range 2·8–5·7 mm, 5·7–11·9 mm and 6·9–14·4 mm, respectively.Conclusion:According to our findings, it can be concluded that by extending the CTV margin by 6·9–14·4 mm, we can ensure that 90% of the pelvic cancer patients will receive ≥ 95% of the prescribed dose in the CTV area.
The data presented here provide information about the role of reconstruction parameters on Positron Emission Tomography (PET) image quantification. Multiple phantom measurements in four different Spheres to Background Ratio (SBR) were performed on Biograph 6 TruePoint TrueV PET/CT scanner. PET raw data were reconstructed with/without resolution recovery algorithm using six various iteration x subsets with five different Full-Width Half-Maximum (FWHM) values of Gaussian post-smoothing filter. The Recovery Coefficient (RC) of six spheres using three common Volume of Interest (VOI) methods (max, 3D-50% Isocontour, and peak) were calculated. Moreover, SUVmax, SUVmean, and SUVpeak and volumetric indices, such as metabolic tumor volume (MTV), volume recovery coefficient (VRC), and total lesion glycolysis (TLG) were measured. RCmax, RC50%, and RCpeak as a function of sphere size were plotted in all reconstruction methods considering different SBRs. The data could be noticeable for standardization and optimization of quantitative metrics in PET imaging.