Manhal Abdul-Rahman Majeed

Prof. Dr. Manhal Abdul-Rahman Majeed

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
MFMina yihya Falih
Mina yihya Falih
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
Objective This study aimed to evaluate the accuracy in terms of trueness and precision of eight intraoral scanners (IOS) and the effect of different finishing line designs on the IOS's accuracy. Materials and Methods Three printed models of the maxillary arch with maxillary right first molar virtually prepared with chamfer, shoulder, and vertical preparation designs were used as master models in this study. Each model was scanned 30 times with each IOS: Medit i700, Planscan Emerald S, CEREC Primescan, TRIOS 3, CS3600, MEDIT i500, Heron 3Disc, and Cerec Omnicam. The trueness was measured by superimposition of the scanned dataset made with IOS and the scanned dataset made with a lab scanner (In Lab Medit T710) that was used as a reference and the deviation was measured and expressed as a color-coded map by the metrology program (Medit compare, version 2.3.5.892), while precision was measured by the superimposition of the scans of each IOS on each other.The data were analyzed statistically using repeated measure analysis of variance (ANOVA) test, one-way ANOVA test, and Bonferroni test at significance level of 0.05. Results The tested IOS showed significant differences in trueness and precision. Medit i700 and CEREC Primescan recorded the highest precision with no significant difference between them, while Medit i700 recorded the highest trueness as compared to other IOS. Each IOS showed significant differences in trueness and precision with the three finishing line designs except CEREC Primescan and Heron 3 disc that showed no significant difference in trueness with the three finishing line designs and CS3600 that showed no significant difference in precision with the three finishing line designs. Conclusion A significant difference in accuracy was found among the tested IOS and the type of finishing line design had a significant effect on IOS's accuracy.

29 June 2023 in Heliyon
Verified
Journal Article
Open access
SJShahad Jabbar Jassim
Shahad Jabbar Jassim
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Sixty cylindrical specimens (5 mm diameter × 3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was treated with a plasma device (PiezoBrush® PZ3 Handheld Device, Relyon Plasma, Regensburg, Germany). G-Multi PRIMER was applied, then self-adhesive cement (G-CEM ONE) was applied using a split mold (1 mm diameter × 3 mm height), and μSBS was tested in a universal testing machine. The surface roughness was measured using a profilometer. Nine additional specimens of each material for wettability test using an optical tensiometer. The data were analyzed using ANOVA and Bonferroni test at a level of significance of 0.05. The highest mean of μSBS was recorded by AII (27.3 MPa), while the lowest was recorded by AI (17.9 MPa). One-way ANOVA test revealed a significant difference among groups. Bonferroni test showed each two subgroups significant difference except subgroups AI, CI and BII, CII, where there was a non-significant difference. For all CAD/CAM materials, conventional treatment increased the surface roughness compared to plasma treatment, while the contact angle decreased after plasma treatment. Plasma treatment increased the μSBS of resin cement to zirconia significantly while not significantly affecting the μSBS of resin nano-ceramic. Conventional treatment of lithium disilicate provided significantly higher μSBS than plasma treatment.

27 February 2026 in European Journal of Oral Sciences
Verified
Journal Article
Closed access
Yasir AlnakibYasir Alnakib
Yasir Alnakib
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
Salvatore SauroSalvatore Sauro
Salvatore Sauro

25 August 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
MAMohammed Hassen Ali
Mohammed Hassen Ali
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
Background/Objectives: Computer-aided manufacturing techniques are divided into subtractive (milling) and additive (3D printing) techniques. The accuracy of both techniques is measured only indirectly by testing the fabricated restorations. However, the role of the fabrication technique is masked by the differences in the materials used. Hence, this study used the same printing resin to print crowns and blocks for milling. Methods: Ten maxillary first premolars were prepared for full crowns and scanned with Primescan Connect IOS, and then crown restorations were designed using Exocad. A CAD/CAM block equal to size C14 was designed in CAD software (Microsoft 3D Builder) (Version 18.0.1931.0). The designed crowns and blocks were printed using three hybrid ceramic materials, namely, Ceramic Crown (SprintRay), Varseosmile Crown plus (Bego), and P-crown (Senertek), using a SprintRay Pro95S 3D-printer. The printed blocks were then used to fabricate the designed crowns using an In-Lab MCXL milling machine. The trueness and marginal and internal gaps of the crowns were then measured using Geomagic Control X metrology software (Version 2022.1). Statistical analysis was performed using the Kruskal–Wallis test, Dunn’s test, one-way ANOVA test, and Tukey’s HSD test. Results: Generally, the milled crowns showed significantly higher trueness but lower fitness than their 3D-printed counterparts (p < 0.05). A significant reverse correlation was found between the trueness and fitness of the fabricated restorations. Conclusions: The fabrication technique significantly influenced the accuracy of the hybrid ceramic crowns. Milling offered superior trueness, whereas 3D printing resulted in better internal and marginal adaptation.

16 September 2025 in Polymers
Verified
Journal Article
Open access
Yasir AlnakibYasir Alnakib
Yasir Alnakib
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
This study evaluated a biomimetic filler strategy for two-step universal dental adhesives by integrating amine-functionalized mesoporous silica nanoparticles (MSNs) loaded with polyacrylic acid-stabilized amorphous calcium phosphate (PA–ACP) into the primer phase. MSNs were synthesized and characterized by FTIR, N2 sorption (BET), and HRTEM to confirm structural integrity and effective PA–ACP loading. Two commercial adhesives (G2 Bond and OptiBond eXTRa) were modified by incorporating different volumes fractions (10, 15, 20 vol%) of PA–ACP/MSN. Wettability (contact angle), microtensile bond strength (μTBS), and cytotoxicity (indirect MTT assay using human periodontal ligament fibroblasts, HPLFs) were assessed. The results demonstrated that incorporating up to 15 vol% PA–ACP/MSN maintained favorable wettability and bond strength, comparable to those of the unmodified controls. At 20 vol%, significant increases in contact angles and reductions in bond strength indicated impaired primer infiltration. Cytotoxicity testing confirmed high fibroblast viability (>70%) across all tested concentrations, verifying the biocompatibility of PA–ACP/MSN-filled primers. This work confirms the feasibility of a biomimetic adhesive design using PA–ACP/MSN in the primer phase without compromising immediate wettability and immediate μTBS up to 15 vol%. Remineralization is a potential capability that requires verification in future studies.

10 December 2025 in Odovtos - International Journal of Dental Sciences
Verified
Journal Article
Open access
PDF file
ZMZaidoon Hasan Mohammed
Zaidoon Hasan Mohammed
MMManhal Abdul-Rahman Majeed
Manhal Abdul-Rahman Majeed
To compare and assess the fracture strength of indirect overlay restorations bonded using various bonding techniques: sonically activated composite materials, preheated composite materials, and adhesive resin cement. The restorations were fabricated utilizing two distinct categories of all-ceramic CAD/CAM materials: reinforced resin composite blocks and lithium disilicate blocks. Depending on the CAD/CAM block type utilized for constructing the indirect overlay restorations, two main groups of 24 teeth each were created from the 48 human maxillary first premolar teeth that were ready for restorations. Group A consisted of indirect overlays made of lithium disilicate (IPS e.max CAD) blocks, whereas Group B used reinforced resin blocks (BRILLIANT Crios) for indirect overlays. subsequently according to the type of cement utilized in cementation. After the prepared teeth were scanned using the CEREC Omnicam digital intraoral scanner, indirect overlay restorations were designed utilizing CEREC Premium programme (version 4.4.4), and additional milling was carried out using the CEREC MC XL milling device. A computer-controlled universal testing machine (LARYEE, China) was then used to apply compressive axial loads to all cemented indirect overlay restorations at a crosshead speed of 0.5 mm/min till occurrence of fracture. A Student's t-test, LSD test, and one-way ANOVA test were utilized to analyze the data at a significance level of 0.05. This in vitro investigation revealed the greatest fracture strength mean value in the indirect overlays cemented with resin cement compared to other types of cement, regardless of the CAD/CAM block type. Depending on the findings of this research, regardless of the cement type, the mean fracture strength values of the indirect overlays made from both CAD/CAM blocks exceed the maximum biting force in the premolar area, indicating that both block types may be utilized clinically as overlay restorations in the premolar area.