Li Defa

Li Defa


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XLXiaoyi Li
Xiaoyi Li
JGJianxin Guo
Jianxin Guo
HYHuifeng Yang
Huifeng Yang
YWYonghui Wu
Yonghui Wu
ZXZhongjian Xie
Zhongjian Xie
LDLi Defa
Li Defa
In recent years, viral co-infections, particularly with respiratory viruses, have resulted in more complex symptoms, a greater disease burden, and increased challenges in clinical decision-making. These complexities underscore the urgent need for improved diagnostic tools in the managing acute respiratory infections. To address the limitations of conventional qPCR and current POCT methodologies, we developed a passively driven microfluidic chip capable of rapidly screening multiple respiratory viruses. This platform is particularly suited for the point-of-care diagnosis of viral co-infections. Our device integrates nucleic acid amplification and CRISPR-based detection within a single, passively operated system. By utilizing a rapid, 10-minute sample preparation protocol and a 35-minute on-chip assay, this platform enables the multiplex detection of influenza A/B, human parainfluenza virus, and SARS-CoV-2. The total assay time from sample to answer is approximately 45 min, with equipment requirements minimized to a heating block. The assay demonstrated a detection sensitivity of about 10 copies/µL for viral RNA in dilution series experiments. The sensitivity of the assay was 98.44% (95% CI: 91.6%–99.96%), and the specificity was 100% (95% CI: 79.4%–100%). The system combines CRISPR-Cas12a-mediated sensing with reverse transcription recombinase polymerase amplification (RPA) for highly specific nucleic acid detection. The chip design utilizes capillary action and gravity-driven flow for autonomous fluid control, while lyophilized reagent preloading ensures storage stability and minimizes user intervention.

24 June 2026 in Diagnostic Microbiology and Infectious Disease
Verified
Journal Article
Closed access
HYHuifeng Yang
Huifeng Yang
XLXiaoyi Li
Xiaoyi Li
YSYimin Su
Yimin Su
JGJianxin Guo
Jianxin Guo
TWTengfei Wang
Tengfei Wang
LDLi Defa
Li Defa

26 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
HYHuifeng Yang
Huifeng Yang
XQXin Qiu
Xin Qiu
ZCZhi Chen
Zhi Chen
LDLi Defa
Li Defa
HZHan Zhang
Han Zhang
ZXZhongjian Xie
Zhongjian Xie

Although noninvasive glucose monitoring in sweat is a promising, pain-free method for diabetes management, it requires highly sensitive and stable sensors to overcome practical limitations. To overcome this challenge, a photoelectrochemical sensor based on a plasmon-enhanced black phosphorus (BP)/gold (Au) heterojunction was developed in this study. BP nanosheets possess a unique layered structure and intrinsic catalytic activity, but their instability and limited efficiency hinder direct use. Therefore, BP/Au was synthesized using the one-pot method. First-principles calculations revealed that single-layer BP behaved as a quasi-direct bandgap semiconductor. In comparison, the BP/Au heterojunction exhibited metallic characteristics, with anisotropic electron mobility reaching 1.62 cm2·V−1·s−1 along one direction. Charge density analysis confirmed directional charge transfer. Au donated electrons to adjacent P atoms, whereas P atoms forming shorter bonds lost charge. This process was associated with plasmon-assisted photoexcitation at the Au/BP interface, which modulated interfacial charge distribution and enhanced photoelectrochemical activity. By leveraging the Au component’s surface plasmon resonance, the heterojunction considerably augmented light absorption, accelerated interfacial electron transfer, and utilized the wrinkled BP layers to provide abundant active sites. This synergistic effect substantially lowered the oxidation activation energy of glucose. The resulting sensor achieved exceptional performance, with a sensitivity of 266.9 μA·μM−1·cm−2, a low detection limit, and a wide linear range well-suited for detecting glucose in sweat. The findings emphasized the potential of plasmon–semiconductor coupling for advancing noninvasive glucose monitoring and provided valuable design principles for sweat sensors based on metal–semiconductor heterojunctions.