In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.
A monoclonal antibody for microcystin–leucine–arginine (MC-LR) was produced by cell fusion. The immunogen was synthesized in two steps. First, ovalbumin/ bovine serum albumin was conjugated with 6-acetylthiohexanoic acid using a carbodiimide EDC (1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride)/ NHS (N-hydroxysulfosuccinimide) reaction. After dialysis, the protein was reacted with MC-LR based on a free radical reaction under basic solution conditions. The protein conjugate was used for immunization based on low volume. The antibodies were identified by indirect competitive (ic)ELISA and were subjected to tap water and lake water analysis. The concentration causing 50% inhibition of binding of MC-LR (IC50) by the competitive indirect ELISA was 0.27 ng/mL. Cross-reactivity to the MC-RR, MC-YR and MC-WR was good. The tap water and lake water matrices had no effect on the detection limit. The analytical recovery of MC-LR in the water samples in the icELISA was 94%–110%. Based on this antibody, an immunochromatographic biosensor was developed with a cut-off value of 1 ng/mL, which could satisfy the requirement of the World Health Organization for MC-LR detection in drinking water. This biosensor could be therefore be used as a fast screening tool in the field detection of MC-LR.
Large differences in quality existed between soybean samples. In order to rapidly detect soybean quality between samples from different areas, we have developed near‐infrared spectroscopy (NIRS) models for the moisture, crude fat, and protein content of soybeans, based on 360 soybean samples collected from different areas. Compared with whole kernels, soybean powder with particle sizes of 60 mesh was more suitable for modeling of moisture, crude fat, and protein content. To increase the reproducibility of the prediction model, uniform particle sizes of soybeans were prepared by grinding and sieving soybeans with different sizes and colors. Modeling analysis showed that the internal cross‐validation correlation coefficients (Rcv) for the moisture, crude fat, and protein content of soybeans were .965, .941, and .949, respectively, and the determination coefficients (R2) were .966, .958, and .958. NIRS performed well as a rapid method for the determination of routine quality parameters and provided reference data for the analysis of soybean quality using FT‐NIRS.
Paper-based lateral flow immunoassays (LFIAs) are an interesting on site technique for detecting heavy metals. Pb(II) is one of the toxic heavy metals in polluted environmental water. This paper reports the synthesis and characterization of three Fe3O4-based nanoadsorbents that show different performance to Pb(II), Cu(II), Cd(II), Hg(II), As(V), Zn(II), Fe(III), Ca(II), Mg(II), Mn(II), and Al(III) when a GO or an amino group is introduced. Compared with Fe3O4, Fe3O4-GO showed higher adsorption percentage to many heavy metal ions under slightly acid condition. The negative surface on Fe3O4@NH2 had favourable interactions for four main divalent metal ion adsorption, which followed the order: Pb(II) > Cu(II) > Hg(II) > Cd(II). Combined with antibody-functionalized AuNPs showed high affinity and specificity toward Pb(II), an Fe3O4@NH2-based LFIA with five times greater sensitivity for detecting Pb(II) in lake water was developed. The cut-off value of this Fe3O4@NH2-combined LFIA method for detection Pb(II) in lake water was 20 ng/mL and the detection result for 10 ng/mL Pb(II) was obviously observable by the naked eye or a strip reader machine. This detection strategy could be readily adapted for other small molecules or biomolecules as an ultrasensitive screening tool.