In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.
17 April 2015 in Journal of Radiological Protection
Monte Carlo modelling has been performed in support of efforts to establish emergency dosimetry services based on optically or thermally stimulated luminescence (OSL/TL) of the Al 2 O 3 substrate present on the resistors found in mobile phones, which can act as fortuitous retrospective dosemeters for photon exposures. Specifically, a range of exposure conditions has been modelled to assess the dependence of the dosimetry on factors such as the position of resistors within a phone, the orientation of the phone relative to the source, and the location of the phone relative to its owner. Variations due to the resistors’ positions and the phone’s orientation were generally found to contribute just a few percent to the uncertainty on the dose assessments, though the electrical contacts surrounding the resistors could potentially enhance these by several 10s of percent. But, the location of the phone was found to impact dosimetry greatly. The largest discrepancies in the results were found for low-energy exposures: for 192 Ir, differences of up to an order-of-magnitude were found between resistor and whole body doses. The outcome of the work was to derive correction / calibration factors that can be applied to estimate whole body doses from OSL/TL readings, the accurate application of which would depend on the knowledge of the exposure geometry and the degree of conservatism acceptable for the dose assessment.
30 July 2020 in Journal of Radiological Protection
Endovascular aneurysm repair (EVAR) is a well-established minimally invasive technique that relies on x-ray guidance to introduce a stent through the femoral artery and manipulate it into place. The aim of this study was to estimate patient organ doses from EVAR procedures using anatomically realistic computational phantoms and detailed exposure information from radiation dose structured reports (RDSR). Methods: Lookup tables of conversion factors relating kerma area product (PKA) to organ doses for 49 different beam angles were produced using Monte Carlo simulations (MCNPX2.7) with ICRP adult male and female voxel phantoms for EVAR procedures of varying complexity (infrarenal, fenestrated/branched and thoracic EVAR). Beam angle specific correction factors were calculated to adjust doses according to x-ray energy. A MATLAB function was written to find the appropriate conversion factor in the lookup table for each exposure described in the RDSR, perform energy corrections, and multiply by the respective exposure PKA. Using this approach, organ doses were estimated for 183 EVAR procedures in which RDSRs were available. A number of simplified dose estimation methodologies were also investigated for situations in which RDSR data are not available. Results: Mean estimated bone marrow doses were 57 (range: 2-247), 86 (2-328) and 54 (8-250) mGy for infra-renal, fenestrated/branched and thoracic EVAR respectively. Respective effective doses were 27 (1-208), 54 (1-180) and 37 (5-167) mSv. Dose estimates using non-individualised, average conversion factors, along with those produced using the alternative Monte Carlo code PCXMC, yielded reasonably similar results overall, though variation for individual procedures could exceed 100% for some organs. In conclusion, radiation doses from x-ray guided endovascular aneurysm repairs are potentially high, though this must be placed in the context of the life sparing nature and high success rate for this procedure.
A review was undertaken of studies reporting increased DNA damage in circulating blood cells and increased organ doses, for X-ray exposures enhanced by iodinated contrast media (ICM), compared to unenhanced imaging. This effect may be due to ICM molecules acting as a source of secondary radiation (Auger/photoelectrons, fluorescence X-rays) following absorption of primary X-ray photons. It is unclear if the reported increase in DNA damage to blood cells necessarily implies an increased risk of developing cancer. Upon ICM-enhancement, the attenuation properties of blood differ substantially from surrounding tissues. Increased energy deposition is likely to occur within very close proximity to ICM molecules (within a few tens of micrometres). Consequently, in many situations, damage and dose enhancement may be restricted to the blood and vessel wall only. Increased cancer risks may be possible, in cases where ICM molecules are given sufficient time to reach the capillary network and interstitial fluid at the time of exposure. In all situations, the extrapolation of blood cell damage to other tissues requires caution where contrast media are involved. Future research is needed to determine the impact of ICM on dose to cells outside the blood itself and vessel walls, and to determine the concentration of ICM in blood vessels and interstitial fluid at the time of exposure.
A new head band dosemeter, for the measurement of eye lens dose in terms of Hp(3), has been type tested by Public Health England's Centre for Radiation, Environmental and Chemical Hazards [formerly part of the UK Health Protection Agency (HPA)]. The type tests were based on the International Standard ISO 12794, drawing also upon earlier work at HPA. The results show that, unlike many existing dosemeters, the new head band dosemeter correctly measures Hp(3) for beta radiations as well as photons.
The Public Health England fortuitous dosimetry capability is reviewed, with particular attention focussed on the derivation of its energy and fading corrections, the Monte Carlo techniques used to generate the calibration factors between phone and body doses, and the procedures set in place to facilitate a reliable and effective service.